Aiphone GT-AD Manual


Læs gratis den danske manual til Aiphone GT-AD (24 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 9 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 5 anmeldelser. Har du et spørgsmål om Aiphone GT-AD, eller vil du spørge andre brugere om produktet?

Side 1/24
Quick Start Installation Guide
This is an abbreviated Installation and Programming manual for the GT Series. The complete GT Series
Installation Manual is supplied with the GT-BC Bus Control Unit. Additional manuals are available online,
including The GT Standard & Expanded Setting Manual and GT Multi Building Installation and Setting Manuals.
The GT Setup Tool for programming tenant names and numbers and other settings can be downloaded from
www.aiphone.net.
ATTENTION:
GT SERIES
Multi-Tenant Entry Security
The illustrations used in this manual may di󰀨er from the actual product.
2 | GT Series Quick Start Guide
Table of Contents
System Wiring
Standard system wiring: audio only..................................................................................................................................3
Standard system wiring: audio/video................................................................................................................................4
Expanded system wiring...................................................................................................................................................5
Option connector wiring: tenant stations...........................................................................................................................5
Settings
Dip switch settings: entrance and guard station ID settings.............................................................................................6
.
Dip switch settings: entrance station.................................................................................................................................6
Programming
Entering tenant information..............................................................................................................................................7
Addressing tenants via dip switch method.........................................................................................................................8
Entering guard station and entrance station information...................................................................................................9
Transfer data to other guard/entrance stations................................................................................................................10
Uploading to stations via USB........................................................................................................................................11
GT Setup Tool for Android
Download from Google Play...........................................................................................................................................11
Downloading settings................................................................................................................................................11-12
Editing settings...............................................................................................................................................................12
Uploading settings..........................................................................................................................................................13
Programming: addressing tenants via handshake method.......................................................................................14-15
GT-MCX Network Adaptor
Multi-Building System Wiring with GT-MCX....................................................................................................................16
GT-MCX: network adaptor..............................................................................................................................................17
Dip switch settings: tenant section and main section......................................................................................................17
System Programming with Multiple GT-MCX: multi-building......................................................................................18-19
Programming: addressing tenants via dip switch method...............................................................................................19
Programming: entering resident info..............................................................................................................................20
Programming: entering entrance station and guard station information.........................................................................21
Programming: transfer data to entrance stations and guard stations.............................................................................22
Programming: uploading to GT-MCX via LAN................................................................................................................23
Programming: sharing handshake data..........................................................................................................................24
*DP
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
CN1
CN2
CN2
CN1
CN1
CN1
PS-2420UL
GT-BCGT-VBC
PS-2420UL PS-2420UL
1P
1P1P
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P
1P x 2
1P x 2
1P x 2
1P x 2
GT-4Z
GT-4Z
Doorbell
1P
GFK-PS
GT-1C
GT-1C
1P x 2
1P x 2
Trunk Line No. 1
Homerun using
GT-4Z (max. 6)
Trunk Line No. 2
Loop wiring
(max. 25)
Trunk Line
No. 3-6
GT-MK w/
GFW-S
GT-MK w/
GFW-S
Security Guard/Concierge Stations (max. 2)Entrance Stations (max. 5)
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
GT Standard Configuration Sample
R1
R2
+
-
+
-
R1 R2R1 R2
CN1
CN1
CN100
CN100
+
-
+
-
ELC
ELM
ELB
PT
Mag
Lock
ELC
ELM
ELB
PT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
PS24
PS24
GT-BC
Loop Wiring Method
Max. of 25 stations per loop / trunk
Homerun Wiring Method
* Distribution Point:
(GTW-DP) Available in
North America. (GFC)
Available in Europe. This
can be any device that
parallels or commons
the R1 / R2 connection.
(Terminal strip, punch
down block, wire nuts,
etc.)
**Tenant stations shown
are the GT-1A. The
GT-1D tenant stations
can also be used
and wired in the same
manner.
Each pair of wires
should be in a
separately jacketed
cable (audio, video,
and power wiring).
Door
Strike
STANDARD SYSTEM WIRING: AUDIO ONLY
R1
R1
R2
R2
Max. wire distance from distribution point to any tenant is 980’ (300m).
Max. cumulative wire distance is 8200’ (2500m).
Refer to the GT Series Installation Manual for complete wire distance information.
WIRE TYPE
: Audio Line
: Video Line
POWER
PS24
PS-2420UL
PS-2420
PS-2420S
PS-2420BF
PS-2420DM
PT
Power Transformer
(Use proper power
for the Strike or Mag
Lock being used.)
3
**
ELM: Make (N/O)
ELC: Common
ELB: Break (N/C)
+
-
GT-MKB-N
+
-
GT-MKB-N
+
-
PS24
ON
1 2 3
4
#1
ON
1 2 3
4
#2
R1
R2
R1
R2
IN
OUT
R1
R2
R1
R2
OUT
IN
Use the dip switch method of programming shown below when installing the GT-1C7(-L), GT-1C7W(-L), GT-1M3(-L),
or GT-2C(-L). When installing the GT-1A or GT-1D, use the handshake method shown on pages 14-15 after uploading
tenant, entrance, and guard information to the stations. If using a mix of stations that allow for dip switch settings
(GT-1C7(-L), GT-1C7W(-L), GT-1M3(-L), and GT-2C(-L)) and stations that do not (GT-1A, GT-1D), it is recommended
to program all stations using the handshake method.
Step 1: Create an ID correlation table for the tenant stations using a binary / SW2 Dip Switch - ID chart.
The chart below is for up to 48 stations in a non-expanded system.
The full Dip Switch chart can be downloaded from https://www.aiphone.net/product/support/gt/
Step 2:
Set the SW2 dip switches found on the back of the GT-1C7(-L), GT-1C7W(-L), GT-1M3(-L), and GT-2C(-L)
according to the correlation table created in the previous step.
Step 3:
Enter the ID from the correlation table in Step 1 into the Unit Link-ID Setting for each station.
Step 4: Click Save , and then
Yes
.
PROGRAMMING: ADDRESSING TENANTS VIA DIP SWITCH METHOD
8 | GT Series Quick Start Guide
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
Dip Switch ID
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
Dip Switch ID
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34
S35
S36
Dip Switch ID
S37
S38
S39
S40
S41
S42
S43
S44
S45
S46
S47
S48
Dip Switch ID
On
O󰀨
128 64 32 16 8 4 2 1
SW2
GT-1A or GT-1D: Leave blank.
Program via handshake method.
Pages 14-15.
GT-2C(-L)GT-1M3(-L)GT-1C7(-L)
If updating dimensions, be sure to update the GLC layer too.
Please refer to the Product Dimensions Master located here:
H:\Engineering Services\Product Dimensions Master Document\Product Dimensions Master.xlsx
JO-1MDW
JO-1MDW
8-1/4" 1-1/16"
6-1/8"
GT-1C7W(-L)
9
Programming Guard/Entrance Information
Step 1: Click the + Guard Station , then select the guard station to program. Click Entrance Info, then enter 1 for
the Section ID. Enter the Entrance ID (1-16), Entrance #, and Entrance Name (not required).
Step 2: Click Guard Info, then enter 1 for the Section ID. Enter the Guard ID (1-4), Guard # and Guard Name (not
required) of the other guard station in the system.
Note: This step is not required if only using 1 guard station.
Step 3: Repeat Steps 1 and 2 for each guard station.
Step 4: Click the +Entrance ,then select an entrance station. Repeat Step 2 to enter the Guard Info for each
entrance station. Since entrance stations cannot call other entrance stations, only guard station information
will be entered for the entrance station.
Step 5: Click Save , and then
Yes
.
PROGRAMMING: ENTERING GUARD STATION AND ENTRANCE STATION INFORMATION
11
PROGRAMMING: UPLOADING TO STATIONS VIA USB
Step 1: Click Upload
.
Step 2: From the Upload (PC -> Station) menu, select the USB radio button. Select the desired station’s radio
button and click
OK
. Click
Yes
in the popup window asking if it’s ok to overwrite the selected station.
Enter the Admin Passcode then click
OK
.
GT SETUP TOOL FOR ANDROID
TM
: DOWNLOAD FROM GOOGLE PLAY
TM
GT SETUP TOOL FOR ANDROID: DOWNLOADING SETTINGS
Step 3: Repeat for all entance/guard stations.
The Aiphone GT Setup Tool for Android app can be used to create and upload setting les to the GT-DMB(-N, -LVN)
and GT-DB-VN entrance stations as well as the GT-MKB-N guard station. It is recommended to use the GT Support
Tool for Windows for the initial setting le creation and uploading to the stations, then use the app for downloading and
editing the setting le when changes need to be made. The following sections will cover how the app can be used for
downloading and editing the setting le, then uploading. For complete information on using the app for programming,
refer to the GT SYSTEM SETTING MANUAL/Aiphone GT Setup Tool for Android.
Open the Aiphone GT Setup Tool
for Android and tap DOWNLOAD
SETTING BY NFC.
Tap the appropriate authorization
level and then tap OK.
Step 1 Step 2
Step 3
Enter the appropriate passcode.
Ensure that Overwrite Unit Link-ID
settings is checked, then tap OK.
16 | GT Series Quick Start Guide
MULTI-BUILDING SYSTEM WIRING WITH GT-MCX
*DP
+
-
A1 A2R1 R2
R1
R2
+
-
+
-
PS24
GT-BC
+
-
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
B1 B2R1R2
GT-VBC
B1 B2R1R2 B1 B2R1R2
B1 B2R1R2 B1 B2R1R2 B1 B2R1R2
R1R2B1 B2
OUT (1) OUT (2)
OUT (3) OUT (4)
IN
LINE OUT
SW1
A
B
GT-4Z
IN
OUT
IN
OUT
IN
IN
IN
IN
R1
R1
R2
R2
SW1
A
B
SW1
A
B
SW1
A
B
SW1
A
B
SW1
A
B
SW1
A
B
To additional units
+
-
PS24
To additional units
+ -
R1
R2
B1
B2
A1
A2
GT-MCX
OUT
IN
LAN
Network
Switch
*DP
+
-
A1 A2R1 R2
R1
R2
+
-
+
-
PS24
GT-BC
+
-
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
GT-VBC
R1
R1
R2
R2
1
4
GHI
7
PQRS
#0
ABC
JKL
TUV
5
8
2
6
9
WXYZ
MNO
3
DEF
1
4
GHI
7
PQRS
#0
ABC
JKL
TUV
5
8
2
6
9
WXYZ
MNO
3
DEF
+
-
+
-
PS24
B1 B2R1 R2
+ -
R1
R2
B1
B2
A1
A2
GT-MCX
OUT
IN
LAN
Network
Switch
TENANT SECTION
MAIN SECTION
*
Distribution Point:
(GTW-DP)
Available in North
America. (GFC) Available
in Europe.
This can be
any device that parallels
or commons the R1 / R2
connection. (Terminal strip,
punch down block, wire
nuts, etc.)
A tenant section can contain
tenant stations, entrance
stations, and guard stations.
A main section can contain
all-in-one entrance stations
and guard stations only. Main
sections can call to tenant
sections but tenant sections
cannot call to other tenant
sections.
Section ID’s 1-24
Section ID’s 25-32


Produkt Specifikationer

Mærke: Aiphone
Kategori: Ikke kategoriseret
Model: GT-AD
Vægt: - g
Antal pr. pakke: 1 stk
Produktfarve: Black, White
Mærke kompatibilitet: Aiphone

Har du brug for hjælp?

Hvis du har brug for hjælp til Aiphone GT-AD stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Aiphone Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer