APC Back-UPS BX550CI-AR Manual

APC UPS Back-UPS BX550CI-AR

Læs gratis den danske manual til APC Back-UPS BX550CI-AR (4 sider) i kategorien UPS. Denne vejledning er vurderet som hjælpsom af 29 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 15 anmeldelser. Har du et spørgsmål om APC Back-UPS BX550CI-AR, eller vil du spørge andre brugere om produktet?

Side 1/4
Installation and Operation
Back-UPS BX550CI-AR
Safety
Installation
Connect the Battery
Pull down on the battery connector handle, and then push it into the unit.
Connect Equipment
Connect equipment to the battery and surge protected outlets. These outlets
provide battery backup power and surge protection to all connected equipment.
Connect AC Power Cord
Connect the Back-UPS power cord directly into a wall outlet.
Turn on the Back-UPS
Press the Power ON button located on the front of the Back-UPS. The Power On LED will illuminate and a
single short beep will be audible to indicate that the Back-UPS is providing protection for connected
equipment.
The Back-UPS battery charges fully during the first 10 hours while connected to utility power. The Back-UPS
battery will charge while the Back-UPS is switched on or off and is connected to utility power. Do not expect
full battery run capability during the initial charge time.
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the unit are not blocked. Allow adequate space for proper
ventilation.
Environmental factors impact battery life. High temperatures, poor quality A/C power,
and frequent, short duration discharges will shorten battery life.
Connect the Back-UPS directly to a wall outlet. Do not use surge protectors or
extension cords.
1ON/OFF button
2Battery connector
3Circuit breaker
4Input power cord
5Battery and surge protected outlets
bu195a
2
Transfer Voltage and Sensitivity Settings
Automatic Voltage Regulation boosts the utility voltage when it drops below safe levels. This allows the equipment
that is connected to the unit to operate during low voltage conditions. It will also regulate high voltage down to
safer levels.
The Back-UPS will switch to battery power if the input voltage level becomes too low for the Automatic Voltage
Regulation feature to compensate, or if the utility power is distorted.
If the Back-UPS switches to battery power too frequently or too infrequently, adjust the transfer voltage and
sensitivity settings:
1. Turn off the Back-UPS. Plug it into utility power.
2. Press and hold ON/OFF until the LED repeatedly flashes. The unit is now in Program Mode.
3. Release the button. The LED will flash once, twice, or three times per second, indicating the current
setting.
4. Press ON/OFF within two seconds to change the setting. Each time the button is pressed, the LED will
flash at a different rate: once, twice, or three times per second, indicating the new setting. Continue
pressing the button until the desired setting is reached. If the button is not pressed within five seconds, the
Back-UPS will exit the Program Mode.
Status Indicators
LED Flashing
Transfer
Voltage Setting
Input Voltage
Range Usage
Once per second Low 155 - 280 The Back-UPS will switch to battery power less often. Use
with equipment that is not sensitive to low or high level
voltage levels or minor voltage waveform distortions.
Twice per second Medium
(factory default)
160 -280 Default, use in normal conditions.
Three times per second High 165 - 270 The Back-UPS will switch to battery power during any
small fluctuation in voltage. Use with equipment that is
sensitive to low or high level voltage levels or minor voltage
waveform distortions.
LED Audible Alarm Condition
On Off Online - Back-UPS is supplying conditioned utility power to the connected
equipment
Constant Tone On Line Overload - The power drawn by the connected equipment exceeds the
power capacity of the unit
On (Off during
4 beeps)
4 beeps repeated
every 30 seconds
On-Battery - Back-UPS is supplying battery power
Flashing Rapid Beeping
(every 1/2 second)
Low Battery Warning - There are 2 minutes of run time remaining
Constant tone Bad Battery Detected - Battery needs to be charged, or is at end of life. (See
Battery Replacement.)
Chirp every 2
seconds
Charger Warning -Back-UPS has experienced an internal problem, but
continues to power the load. Contact APC Technical Support
Off Short beep every
4 seconds
Low Battery Shutdown - During On Battery operation the battery power was
almost completely exhausted, and the Back-UPS is waiting for utility power to
return to normal
Constant Tone On Battery Overload - Connected equipment requires more power than provided
by the Back-UPS battery. Unplug devices one at a time to remove overload, if not
corrected Contact APC Technical Support
Constant Tone Charger Fault - Back-UPS has an internal problem, and is no longer powering
the load. Contact APC Technical Support