Carrier AquaSnap 30RC Manual

Carrier Klimaanlæg AquaSnap 30RC

Læs gratis den danske manual til Carrier AquaSnap 30RC (160 sider) i kategorien Klimaanlæg. Denne vejledning er vurderet som hjælpsom af 25 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 13 anmeldelser. Har du et spørgsmål om Carrier AquaSnap 30RC, eller vil du spørge andre brugere om produktet?

Side 1/160
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300253-01 Printed in U.S.A. Form No. 30RC-2SI Rev. A Pg 1 10-23 Replaces: 30RC-1SI
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Step 1 — Place, Rig, and Mount the Unit . . . . . . . . . 3
•PLACING UNIT
MOUNTING UNIT
EXPORT SHIPPING RAILS
RIGGING UNIT
COMPRESSOR SOUND BLANKETS
Step 2 — Make Evaporator Fluid, Partial Heat
Recovery, and Drain Piping Connections . . . . . . . 79
FREEZE PROTECTION
BPHE UNITS WITHOUT HYDRONIC PUMP PACKAGE
DX UNITS WITHOUT HYDRONIC PUMP PACKAGE
BPHE UNITS WITH HYDRONIC PUMP PACKAGE
DX UNITS WITH HYDRONIC PUMP PACKAGE
UNITS WITH OPTIONAL PARTIAL HEAT RECOVERY
FOR ALL UNITS
Step 3 — Fill the Chilled Water and Partial Heat
Recovery Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
WATER SYSTEM CLEANING
WATER TREATMENT
SYSTEM PRESSURIZATION
FILLING THE SYSTEM(S)
SET WATER FLOW RATE
PUMP MODIFICATION/TRIMMING
•PUMP VFD
SENSORLESS CONTROL (CLOSED LOOP) — ACTIVE
SETUP 1
REMOTE SENSOR (CLOSED LOOP) — ACTIVE
SETUP 2
REMOTE CONTROLLER (OPEN LOOP) — ACTIVE
SETUP 3
PREPARATION FOR YEAR ROUND OPERATION
FREEZE PROTECTION
PREPARATION FOR WINTER SHUTDOWN
Step 4 — Make Electrical Connections . . . . . . . . . 105
POWER SUPPLY
•POWER WIRING
CONTROL POWER
FIELD CONTROL OPTION WIRING
DUAL CHILLER CONTROL OPTION
CARRIER COMFORT NETWORK
®
(CCN)
COMMUNICATION BUS WIRING
BACNET IP OR ETHERNET COMMUNICATION
NON-CCN COMMUNICATION WIRING
MS/TP WIRING RECOMMENDATIONS
Step 5 — Install Accessories . . . . . . . . . . . . . . . . . 158
ENERGY MANAGEMENT MODULE
LOW AMBIENT TEMPERATURE OPERATION
MINIMUM LOAD ACCESSORY
UNIT SECURITY/PROTECTION ACCESSORIES
COMMUNICATION ACCESSORIES
SERVICE OPTIONS
Refrigerant Circuit . . . . . . . . . . . . . . . . . . . . . . . . . .159
LEAK TESTING
DEHYDRATION
REFRIGERANT CHARGE
SAFETY CONSIDERATIONS
Installing, starting up, and servicing air-conditioning equipment
can be hazardous due to system pressures, electrical components,
and equipment location.
Only trained, qualified installers and service mechanics should
install, start up, and service this equipment. This equipment is not
to be used by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowl-
edge, unless they have been given supervision or instruction.
Untrained personnel can perform basic maintenance functions,
such as cleaning coils. All other operations should be performed
by trained service personnel. Qualified installers and service tech-
nicians are required to have been trained on the following topics
when installing and servicing air-conditioning equipment with
A2L refrigerant such as R-32:
1. Explosive potential of A2L refrigerants
2. Potential ignition sources
3. Safety measures for unventilated and ventilated rooms or
enclosures
4. Refrigerant detectors
5. Concept of sealed components and sealed enclosures
according to IEC 60079-15:2010
6. Correct work procedures for the following:
a. Commissioning
b. Maintenance
c. Repair
d. Decommissioning
e. Disposal
Reference UL 60335-2-40 Annex HH for complete guidelines.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
1. Follow all safety codes.
2. Keep quenching cloth and fire extinguisher nearby when
brazing.
3. Wear safety glasses and work gloves.
4. Use care in handling, rigging, and setting bulky equipment.
It is important to recognize safety information. This is the safety-
alert symbol . When you see this symbol on the unit and in in-
structions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
AquaSnap
®
30RC 065-150 Air-Cooled Chillers and
30RC 067-252 Air-Cooled Chillers with
Greenspeed
®
Intelligence


Produkt Specifikationer

Mærke: Carrier
Kategori: Klimaanlæg
Model: AquaSnap 30RC