Cotech FIB75600v1-pt Manual

Cotech Lys FIB75600v1-pt

Læs gratis den danske manual til Cotech FIB75600v1-pt (4 sider) i kategorien Lys. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Cotech FIB75600v1-pt, eller vil du spørge andre brugere om produktet?

Side 1/4
UITED KINGDOM internet www.clasohlson.co.uk
Ver. 20220516
LED Grow Light
Art.no 36-8557 Modell FIB75600v1-pt
Please read theentire instruction manual before using theproduct and
then save it for future reference. We reserve theright for any errors in text or
images and any necessary changes made to technical data. In theevent of
technical problems or other queries, please contact our Customer Services.
Safety
Do not use thelight if it or its mains lead and plug are damaged in
any way.
Thelight should only be connected to awall outlet with a230 V,
50 Hz power supply.
Do not mount thelight in anenvironment where it is exposed to
water, moisture or extreme temperatures.
Never try to open theproduct, repair or modify it in any way.
Electric shock hazard
Thebulb in this light fitting must only be replaced by aqualified
electrician.
Installation and maintenance work on theproduct involves therisk
of anelectric shock.
If themains lead is damaged it must be replaced by a cable of
identical specifications as theoriginal.
Connecting thelights using aconnector
This product is intended for indoor use only.
Connecting several lights together
Up to 10 light fittings can be interconnected. There are two different
ways of connecting thelights together:
1. Thefirst is with aconnector, which enables thelights to be joined
end to end.
2. Thesecond is using aseries connection cable, which enables
thelights to be joined about 10 cm apart (handy for corner mounting).
1. Push thesupplied connector into
themains socket on thelight fitting.
2. Connect thetwo lights together. Make sure that theconnector is securely
inserted and that both lights are securely connected to each other.
3. Repeat thesame procedure if you wish to connect additional lights.
Connecting thelights using aconnection cable
Installation
Ensure that there are no electrical wires or water pipes in theceiling or
wall where you intend to drill/screw.
1. Mount theceiling bracket using thescrew. Use amasonry drill and
wall plug to create ananchor hole if necessary.
Most plants grow better when not exposed Plant illumination time:
to 24-hour light, they also require aperiod of darkness.
We recommend that thegrow light is used with atimer.
Handy tip
It is agood idea to connect thelight fitting/s to awall socket which
is controlled by anon/off switch.
Class II luminaire.
Thelight bulb is not dimmable.
Switch thelight fitting on and off
by pressing thepower switch.
1. Use thesupplied series connection cable to connect thefirst light to
thesecond.
2. Repeat thesame procedure if you wish to connect additional lights.
Care and maintenance
Thelight fitting should be cleaned using adry cloth or vacuum cleaner.
Unplug thelight fitting from thewall socket if theproduct is not be
used for anextended period.
Instructions for use
Note
Theintensity of thelight is inversely proportional to Distance:
thesquare of thedistance from thesource, which means that if you
double thedistance between thelight and anobject, only aquarter
of thelight will reach theobject. It is therefore important that
thelights are as close as possible to theplants and equally spaced.
Troubleshooting guide
Thelight
doesn’t
come on.
Check that thelight is turned on.
Make sure that themains lead is undamaged and
is securely connected to both thewall socket and
thelight.
Is thewall socket energised?
Check that any interconnected lights are intact and
properly connected to each other.
Responsible disposal
This symbol indicates that this product should not be
disposed of with general household waste. This applies
throughout theentire EU. In order to prevent any harm to
theenvironment or health hazards caused by incorrect waste
disposal, theproduct must be handed in for recycling so that
thematerial can be disposed of in aresponsible manner. When
recycling your product, take it to your local collection facility or contact
theplace of purchase. They will ensure that theproduct is disposed of
in anenvironmentally sound manner.
Specifications
Rated voltage 220–240 V AC, 50/60 Hz
Mains lead 1.8 m
Bulb LED
Photosynthetic photon flux
PPF 17 μmol/s
10 μmol/m²/sPPFD @20 cm
Wavelength Blue 450 nm
660 nmRed
Series connection cable 20 cm
Wattage 8.5 W
IP rating IP20
Operating temperature −30 ºC to +40 ºC
Dimensions 600×24×35 mm
2. Press thelight fitting into thebrackets until it clicks into place.
3. Plug themains lead into awall socket.


Produkt Specifikationer

Mærke: Cotech
Kategori: Lys
Model: FIB75600v1-pt

Har du brug for hjælp?

Hvis du har brug for hjælp til Cotech FIB75600v1-pt stil et spørgsmål nedenfor, og andre brugere vil svare dig