Læs gratis den danske manual til CyberData Systems 011324 (3 sider) i kategorien Modtager. Denne vejledning er vurderet som hjælpsom af 34 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 17.5 anmeldelser. Har du et spørgsmål om CyberData Systems 011324, eller vil du spørge andre brugere om produktet?

Side 1/3
Quick Start Guide 931155B
The IP Endpoint Company
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operations Guide,
which is available in the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011324/
Note You can also navigate to the Downloads tab by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
IEEE 802.3af or 802.3at PoE Switch IEEE 802.3af or 802.3at PoE Injector
Set PoE power type to Class 0 = 15.4W
OR
for high power PoE+ set Class 4 = 30W
CAT6 cable recommended—
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100mbps
Spanning Tree Protocol (STP) must be disabled or Portfast enabled
1
34
2
SIP
OUR PRODUCTS
VOIP PRODUCTS
A
B
011324 SIP PAGING AMPLIFIER Downloads
SIP Paging Amplifier
Quick Start Guide
Quick Start Guide 931155B
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity on the front of
the device during the initialization process. See the following figure:
3.2. The Power (Pwr) LED is GREEN for 802.3af and is BLUE for 802.3at. The
GREEN Status LED and the GREEN Power (Pwr) LED come on
immediately. The Speed (SPD) LED illuminates AMBER for a 100Mb link or
is off for 10MB when the network link to the device is established. The Link/
Activity LED blinks to indicate network traffic.
After about 20 seconds, the GREEN Status LED will blink fast to indicate
that the device is acquiring an IP address and attempting to autoprovision.
It will turn off thereafter until the device has finished booting. When the
device has fully booted, the GREEN Status LED will turn on solid.
If there is no DHCP server available on the network, it will try 12 times for 60
seconds and eventually fall back to the programmed static IP address (by
default 10.10.10.10) or the previously used DHCP address if a prior lease
was established. This process will take approximately 80 seconds.
3.3. When the device has completed the initialization process, press and hold
the RTFM switch for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
SPD
PWR
Link/Act
Status
Volume
Power (Pwr) LED
( )BLUE/GREEN
Speed (SPD) LED
(AMBER) (100Mb)
Link/Activity (Link/Act.) LED
( )GREEN
Status LED
( )GREEN