Læs gratis den danske manual til Daikin EWAQ500F-XR (67 sider) i kategorien Computer køling komponent. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Daikin EWAQ500F-XR, eller vil du spørge andre brugere om produktet?

Side 1/67
CONTROL PANEL OPERATING MANUAL
AIR COOLED SCROLL CHILLER & HEAT PUMP
MICROTECH III CONTROLLER
Software Version 3.01.A
D-EOMHP00607-14EN
D-EOMHP00607-14EN - 1/66
Table of Content
Introduction ........................................................................................................................................... 5
1.1 Controller Features ............................................................................................................................ 6
2 System Outline ............................................................................................................................... 7
2.1 Communication components ............................................................................................................. 7
2.2 Unit I/O Mapping................................................................................................................................ 7
2.3 Unit Mode .......................................................................................................................................... 9
3 Unit Functions ................................................................................................................................ 9
3.1 HEAT, the Unit Mode ......................................................................................................................... 9
3.2 HEAT / COOL w/GLYCOL the Unit Mode ............................................................................................ 9
3.3 HEAT / ICE w/GLYCOL the Unit Mode ................................................................................................ 9
3.4 Calculations ........................................................................................................................................ 9
3.4.1 Evaporator Delta T ...................................................................................................................... 9
3.4.2 LWT Slope ................................................................................................................................. 10
3.4.3 Pull-down Rate.......................................................................................................................... 10
3.4.4 LWT Error .................................................................................................................................. 10
3.4.5 Unit Capacity ............................................................................................................................. 10
3.4.6 Control Band ............................................................................................................................. 10
3.4.7 Staging Temperatures ............................................................................................................... 10
3.5 Unit States ........................................................................................................................................ 11
3.6 Unit Status ........................................................................................................................................ 11
3.7 Power Up Start Delay ....................................................................................................................... 12
3.8 Evaporator Pump Control................................................................................................................. 12
3.9 Evaporator Pump configuration ....................................................................................................... 13
3.9.1 Primary/Standby Pump Staging ................................................................................................ 13
3.9.2 Auto Control ............................................................................................................................. 13
3.10 LWT Target ....................................................................................................................................... 13
3.10.1 Leaving Water Temperature (LWT) Reset ................................................................................ 13
3.10.2 Leaving Water Temperature (LWT) Override ........................................................................... 14
3.10.3 4-20mA Reset ........................................................................................................................... 14
3.10.4 OAT Reset ................................................................................................................................. 14
3.11 Unit Capacity Control ....................................................................................................................... 15
3.11.1 Compressor Staging in Cool Mode ........................................................................................... 15
3.11.2 Compressor Staging in Heat Mode ........................................................................................... 15
3.11.3 Compressors Staging Delay ...................................................................................................... 15


Produkt Specifikationer

Mærke: Daikin
Kategori: Computer køling komponent
Model: EWAQ500F-XR

Har du brug for hjælp?

Hvis du har brug for hjælp til Daikin EWAQ500F-XR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Computer køling komponent Daikin Manualer

Computer køling komponent Manualer

Nyeste Computer køling komponent Manualer