Draper Premier XL Manual


Læs gratis den danske manual til Draper Premier XL (8 sider) i kategorien Projektionslærred. Denne vejledning er vurderet som hjælpsom af 17 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 9 anmeldelser. Har du et spørgsmål om Draper Premier XL, eller vil du spørge andre brugere om produktet?

Side 1/8
Overview - Components
CAUTION
Read and understand all warnings
(Page 2 of this document)
before beginning installation.
1.
Mounting holes
2.
Junction box cover
3.
Dowel
4.
Front cover
(Targa Pictured)
1
2
3
4
Contents
Overview - Components .......................................................................................1
Section 1 - Electrical Connections .....................................................................2
PLEASE READ - Safety Information ....................................................................2
Section 2 - Hanging Screen .................................................................................3
Section 3 - Operation............................................................................................3
Section 4 - Tab-Tension Adjustment Procedure ..............................................3
Section 5 - Limit Adjustments .............................................................................4
Section 6 - Dimensions and Methods of Installation ......................................5
Section 7 - Wiring Diagrams ................................................................................6
Section 8 - Wiring Diagrams ................................................................................7
Section 9 - Accessing Internal Low-Voltage Control Unit
(LVC-IV)
.................8
TOOLS
REQUIRED
POW R RILE D L
PENCIL
TAP ASUE E M RE
HAR ARDW E
(b oth rs)y e
L LEVE
Draper, Inc. | 411 S. Pearl St. Spiceland, IN 47385
draperinc.com | 765.987.7999 | 800.238.7999
© 2020 All Rights Reserved | FORM: Premier_XL_TargaXL_Inst20
Premier XL / Targa XL
Electric projection screen
INSTRUCTIONS
INSTALLATION & OPERATION
If you have any difficulties installing or servicing your
Premier XL / Targa XL, call your dealer or Draper, Inc.
Section 1 - Electrical Connections
Screen operates on 110-120V, 60 Hz. current. Screen ships with internal wiring complete
and control switch
(es)
fully boxed.
Wire to connect screen to switch
(es)
and switch
(es)
to power supply should be furnished
by installer.
Please Note: Screen must be installed in accordance with requirements of Local
Building Codes, Canadian Electrical Code
(CEC)
, CAN/CSA C22.1 and National
Electric Code
(NEC)
, NFPA 70. An appropriate disconnect device shall be provided as
part of building installation.
CAUTION: All operating switches should be "off" before power is connected.
PLEASE READ - Safety Information
FOR OPTIONAL PLUG AND PLAY:
Plug-in power cord option available for motor with internal
low-voltage controller. For reconguration/conversion of
non-detachable power cord to field wiring for models PRE-28,
PRE-29, TAR-28, and TAR-29 Only:
1.
Disconnect cord plug from outlet.
2.
Remove junction box cover.
3.
Disconnect wire nuts from black, white, and green wires.
4.
Remove power cord and strain relief from screen.
5.
Connect black motor wire to "hot" supply wire.
6.
Connect white motor wire to "neutral" supply wire.
7.
Connect green/yellow wire to "ground" supply wire.
8.
Replace junction box cover.
WARNING
Improper installation and use of the Premier XL / Targa XL screen can result in serious injury or death. Primarily, injuries can occur if the unit falls due to
imprecise installation, mishandling of the unit during installation, or installation on an insufcient wall or ceiling structure. Please use extreme care.
1.
Please read the following installation guidelines thoroughly and follow them
carefully. Failure to do so may cause product to fall or otherwise fail, and could
result in serious injury.
2.
Installation and calibration of the unit should only be performed by an
authorized, qualified, and experienced professional. In particular, electrical
work and wiring [indicated in diagram by dashed lines] must be completed only
by a qualified professional electrician who has read this manual completely
and is familiar with the construction and operation of this equipment and the
hazards involved.
3.
Do not afx the unit to walls or ceilings that have inadequate strength
to permanently hold the unit during use. It is the owner’s and installer’s
responsibility to confirm the wall or ceiling to which the unit attaches is
sufficient to permanently hold the weight and stress loads of the unit at all
times. Draper, Inc., is not responsible for improper installation, application,
testing, or workmanship related to the product at place of installation.
4.
It is the installer’s responsibility to make sure appropriate fasteners are used
for mounting.
5.
All hardware must be installed level. Unit must be level and square.
6.
Never leave the area while operating the unit during installation, maintenance,
or normal operation, unless it is secure and safe.
7.
Before testing or operation, carefully inspect the entire area and path
(especially
underneath)
of unit to be sure no persons or objects are in the area.
8.
Turn off power and any nearby equipment or cables carrying electricity before
connecting switches, wires, controls, or electrical components.
9.
Do not wire motors in parallel without written permission from Draper, Inc.
10.
During testing or operation, carefully watch the surrounding area for any
potential safety concerns including nearby persons or objects.
11.
After installation, the entire system, including all sensors, should be carefully
tested to ensure safe and normal operation. Extreme care should be taken
during testing to remain clear of moving parts to avoid possible injury.
12.
Operation of unit should be performed only by authorized and qualified
personnel, who have been trained in its safe and effective operation and
understand its safety features.
13.
The safety features of the unit should never be disabled, bypassed, or
overridden. The system should not be operated until all safety features are
properly and completely installed, calibrated, and tested.
14.
Unit may need to comply with local, state, or district rules and regulations, in
particular when installed in schools. All applicable rules and regulations should
be reviewed before installation and use.
15.
Failure to precisely follow installation guidelines invalidates all
warranties.
16.
Custom products/installations may not be reflected in this manual. Call Draper,
Inc., if you have questions about the installation of custom products or any
questions about your installation.
Before Beginning Installation
1.
Look for any job site conditions that could interfere with installation or
operation of the system.
2.
Read carefully and be sure to understand all installation instructions and
all related operations manuals. These instructions are intended to serve
as a guide for the installer and owner. They should be followed closely and
combined with the expertise of experienced qualified installers. Draper, Inc., is
not responsible for improper installation, application, testing, or workmanship
related to the product at place of installation. Please retain all instructions for
future use.
3.
Open cartons lengthwise.
4.
Locate and lay out all pieces.
5.
Inspect all boxes to make sure you have received the proper unit and parts.
Controls may be shipped separately, or in same carton as unit.
6.
If you have any difculties with installing, servicing, or operating your unit, call
your dealer or Draper, Inc., 765-987-7999.
Important Safety Information Important Safety Information
page 2 of 8
Premier XL / Targa XL


Produkt Specifikationer

Mærke: Draper
Kategori: Projektionslærred
Model: Premier XL

Har du brug for hjælp?

Hvis du har brug for hjælp til Draper Premier XL stil et spørgsmål nedenfor, og andre brugere vil svare dig




Projektionslærred Draper Manualer

Projektionslærred Manualer

Nyeste Projektionslærred Manualer