Edlund Company, 159 Industrial Parkway, Burlington, VT 05401 802-862-9661 www.edlundco.com
Electronic Receiving Scales
Capacity Model ERS-60 (60.0 lbs. X 0.25 ozs., 30.0 Kg X 5 G)
Model ERS-150 (150.0 lbs. X 0.05 lbs., 75.0 Kg X 0.02Kg)
Model ERS-300 (300.0 lbs X 0.1 lbs., 150.0 Kg X 0.05 Kg)
Platform Size Model ERS-60/150 (12" X 12-1/2 )"
Model ERS-300 (19-3/4" X 25-3/4 )"
Overall Size Model ERS-60/150 (12"X 12-1/2 X 2-1/2 )" "
Model ERS-300 (19-3/4 X 25-3/4" " X 4 ")
Power Source 120 VAC, 60 HZ/230 VAC, 50 HZ Output: 12VDC 1000ma
The ERS model scale operates on 6xAA batteries, or a 9-volt power supply (part #PS5005). The scale has an
automatic power off feature. (Which can be programmed to 120 sec., 240 sec., 360 sec., 720 sec., or off) If a
battery is used, the scale will shut off after the programmed time if no weighing operation is performed.
To install the batteries, turn the scale display over, open the battery box, install 6xAA batteries (observing
polarity), and close the cover. If the power supply is used, push the power supply tip into the jack orifice,
making sure the two pieces are properly aligned for a tight seal.
Turn on the scale by depressing the "on/off" switch. Scale readout will show all 8's for approximately 5
seconds and then the zero reading. If the scale is overloaded, a series of horizontal lines will be displayed. If
a load is placed on the scale platform, the weight of this load is shown on the scale display in the units in
which the scale is weighing. You can change the weighing mode by pressing the "Hold/Mode" button.
This load can now be "tared out" i.e. shown as zero on the scale display, by depressing the "Tare" button. If
an additional load is then placed on the platform, the weight of this additional load can also be "tared out" by
depressing the "Tare" button. This tare operation can be repeated up to the capacity of the scale.
If the total load is now removed from the platform, the weight of the total load will be shown as a negative
value on the scale display. This negative value can now be removed from the display by depressing the
"Tare" button. Depressing the "on/off' button at any time will turn the scale off.
To use the "Hold" button, place weight on the platform, then press the "Hold" button until the weight starts
blinking. Release the button, and remove the weight from the platform the display. The values will still show
the amount that was on the platform. To remove, just press the "Tare" button and the display returns to zero.