2.3PanelMountingandRemoving
5.ChangingandSavingTemperatureandHumiditySetValue
5.1Ch miditySetValue
MainOperatingScreen
WhenSET buttonpressed‘’S’’ ledwill
beactiveandtemperaturesetvaluewill
bedisplayed.
TemperatureSetValueScreen
Temperaturesetvaluecan
bechangedwithincrement
anddecrementbuttons.
WhenSET buttonpressed
temperaturesetvaluecanbesaved.
GoesHumiditySET
valuescreen.
Temperaturesetvalueparameter(Default=37.4 )
Temperaturesetvalue,canbeprogrammedbetweenminimumtemperaturesetvalue and
maximumtemperaturesetvalue .
°C
WhenSET buttonpressed
setvaluecanbesaved.
Humidity
Goesbackto
mainoperationscreen.
HumiditySetValue Screen
If no operation is performed in Humidity set value changing mode and temperature set value
changing mode for 20 seconds, device turns to main operation screen automatically.
i
HumiditySetValue Screen
5.1 ProgrammingModeParameterList
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude around
set value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is formed
below or around set value and this zone is
named hysteresis.
Temperature Sensor Offset Parameter ( Default = 0 )
3.2DeviceLabelandConnectionDiagram
3.ElectricalWiringDiagram
3.1SupplyVoltageInputConnectionoftheDevice
4.FrontPanelDefinitionand AccessingtotheMenus
5
7 8 11
9 10
12
BUTTON DEFINITIONS
1. Increment Button :
2. Decrement, Silencing Buzzer Button :
3. Manual Start of Egg Tray Rotator Operation Button:
**
4. Set Button:
5.Alarm led :
6. Heating Output Led :
7.Celcius led :
8.Fahrenheit led :
9. Led :
10. Output Led :
11.Precent Sign ledi :
12.Program led :
** In main operation screen, press this button to change display temperature and humidity sensor
value.
** It is used to increase the value in the Temperature and Humidity Set screens and Programming mode.
** It is used to decrease the value in the Set screen and Programming mode.
** It is used to silence the buzzer.
When the button is released the
engine start will be passive and engine stops.
** In the main operation screen; if this button pressed for the first time, Temperature set value will be
displayed. Value can be changed using increment and decrement buttons. When Set button is pressed
again, value is saved and Humidty set value will be displayed next. Value can be changed using
increment and decrement buttons. When Set button pressed again, value is saved and returns back to
main operating screen.
** To access the programming screen; in the main operation screen, press and hold this button for 5
seconds.
** It is used to save value in the Set screens (Temperature or Humidity) and programming screen.
**
** This led indicates that heating output is active.
** Indicates that device is in C mode.
** Indicates that device is in F mode.
** This led indicates that is active.
** This led indicates that output is active.
** Indicates that device is in programming mode .
o
o
In the main operation screen, if this button pressed engine starts.
It is active when alarm statuses.
Egg Tray Rotator Output
Humidity
** Indicates that device is in Humidity Set screen.
LED DEFINITIONS
Egg Tray Rotator Output
Humidificating
230V CONNECTION DIAGRAMV
TemperatureControlSelectionParameterOn/OfforPID (Default=0)
On - Off selected.
PID selected.
PID - Proportional Control Parameter ( Default =50 )
This parameter value can be adjusted form 0 to 100.
PID - Integral Parameter( Default = 1000 )
This parameter value can be adjusted form 0 to 3600.
PID - Derivative Parameter ( Default = 250 )
This parameter value can be adjusted form 0 to 3600.
PID -Period Time Parameter ( Default = 1 )
This parameter value can be adjusted form 1 to 50 second.
HumiditySensorScaleSelectionParameter(Default=0)
Buzzer Function Selection Parameter( Default = 0 )
Button Protection Parameter ( Default = 0 )
Humidity Alarm Function Selection Parameter ( Default = 0 )
Humidity (Default = 0)
When power is first applied to the device, this time delay must be expired for activation of
Humidity alarm.
Alarm Delay After Power On Parameter
It can be adjusted from 0 to 99 minutes.
Humidity Set Maximum Parameter(Default =Maximum Value of Device Scale)
if humidity alarm is active, this parameter value can be adjusted from humidity alarm set
minimum parameter to maximum value of the device scale.
Alarm
Humidity (Default = 0)
Humidity
Alarm On Delay Time Parameter
AlarmOnDelay Timecanbedefinedwiththisparameter.Itcanbeadjusted
from0to99minutes.
Buzzer is inactive.
Buzzer is active during temperature alarm
Buzzer is active during humidity alarm
Buzzer is active during Temperature sensor failures.
Buzzer is active during Humidity sensor failures.
Buzzer is active during Temperature sensor failures or temperature alarm.
Buzzer is active during Humidity sensor failures or Humidity alarm.
Buzzer is active during Temperature sensor failures or Humidity sensor failures
Buzzer is active during Temperature sensor failures or Humidity sensor failures
or temperature alarm or humidity alarm.
There is no protection.
Temperature setvalue can not be changed.
Humidity set value can not be changed.
Manual engine start is not available.
Humidity set value and Temperature set value can not be changed
Humidity set value can not be change and Manual engine start is not available.
Temperature set value can not be change and Manual engine start is not
available.
Temperature set value and Humidity set value can not be changed. Also
Manual engine start is not available.
Humiditysetvalueparameter(Default=60%)
Humiditysetvalue,canbeprogrammedbetweenminimumHumiditysetvalue andmaximum
temperaturesetvalue .
1-Before mounting the device in your panel, make
sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and
make the unit completely immobile within the
panel
1-Pull mounting clamps from left and right
fixing sockets.
2-Pull the unit through the front side of the
panel
Before starting to remove the unit
from panel, power off the unit and
the related system.
c
Make sure that the power supply voltage is the same indicated on
the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While installing
the unit, supply voltage range must be controlled and appropriate
supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power supply
switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and neutral,
On/Off condition of power supply switch is very important in
electrical connection.
External fuse that on power supply inputs must be on phase
connection.
External fuse that on power supply inputs must be on (+)
connection.
V
Z
c
PowerSupplyInput
c
a
External
Fuse
(1A T)
Note-1
Supply
Switch
7 8
LN
Supply Voltage
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz ,
24V ( %15)50/60Hz ,
24V ( %15) 50/60Hz ,
Z
V
V
V
W
±
±
±
±
10...30 V 1.5 W
Mustbedeterminedinorder.
ON
OFF
Temperature
Control
Output
Set
thSt
Time
thSt
Time
ü
3
4
1
2
5 6
9 10
7 8
11
12
TemperatureSetValueScreen HumiditySetValue Screen
Humiditysetvaluecanbe
changedwithincrementand
decrementbuttons.
RelayOutputs
2
135
468
7910
P/N: ESM-3722
L
N
a
PowerSupplyVoltage
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz,
24V ( %15) 50/60Hz ,
24V ( %15) 50/60Hz ,
Z
V
V
V
W
±
±
±
±
10...30 V 1.5 W
11 12
TemperatureSensorInput
NTC,PTC,PT-100or
ProNemMiniPMI-P
HumiditySensorInput
0/2..10V,0/4..20mA or
ProNemMiniPMI-P
Mustbedeterminedinorder.
3
2
1
1
2
Mustbedeterminedinorder.
Mustbedeterminedinorder.
N
L
7 8 9 10
a
3x3 @250VA V
5A @250VV
LN
230 V ±15%
50/60Hz-1.5VA
V
2 3 41
ALARM
HUM.
5 6 11 12
14A TFuse
+
-
ENGINE
HEAT
N
L
7 8 9 10
a
3x3 @250VA V
5A @250VV
LN
230 V ±15%
50/60Hz-1.5VA
V
2 3 41
ALARM
HUM.
5 6 11 12
14A TFuse
+
-
ENGINE
HEAT
PTC Temperature and 0/4..20mA Humidity Sensor Input connection
VCC
GND
SCL
SDA
ProNem Mini PMI-P Temperature and Humidity Sensor Input Connection
Note: If this parameter is select 0, PID parameters ( , , , , ) will be not observed.
If this parameter select 1, parameter will be not observed.
Auto Tune (Limit Cycle Tuning) Selection Parameter ( Default = )
Device does not do(Limit cycle Tuning) operation.
Device does operation.
HysteresisParameterforTemperature(Default=0.1°C)
From 1 to 10°C for NTC,PTC, PT-100 (0°C, 100°C) ,From 1 to 18°F for NTC,PTC ,PT-100
(32°F, 212°F),From 0.1 to 10.0°C for NTC, PTC, PT-100 (0.0°C,100.0°C), From 0.1 to
18.0°F for NTC, PTC, PT-100 (32.0°F,212.0°F) ,From 1 to 10°C for ProNem Mini PMI-P
(-20°C, 80°C) ,From 1 to 18°F for ProNem Mini PMI-P (-4°F,176°F), From 0.1 to 10.0°C for
ProNem Mini PMI-P (-20.0°C,80.0°C), From 0.1 to 18.0°F for ProNem Mini PMI-P
(-4.0°F,176.0°F).
Minimum Temperature Set Value Parameter ( Default = 10.0°C)
Temperature set value can not be lower than this value. This parameter value can be
adjusted from minimum value of device scale to maximum temperature set value
parameter
Maximum Temperature Set Value Parameter ( Default = 40.0 °C )
Temperature set value can not be greater than this value.
This parameter value can be adjusted from minimum temperature set value parameter
to maximum value of the device scale.
From -10 to 10°C , NTC,PTC , PT-100 (0°C, 100°C)
From -18 to 18°F, NTC,PTC , PT-100 (32°F, 212°F)
From -10.0 to 10.0°C , NTC ,PTC , PT-100 (0.0°C,100.0°C)
From -18.0 to18.0°F NTC, PTC , PT-100 (32.0°F,212.0°F)
From -10 to 10°C ,ProNem Mini PMI-P ( -20°C, 80°C )
From -18 to 18°F,ProNem Mini PMI-P ( -4°F, 176°F )
From -10.0 to 10.0°C, ProNem Mini PMI-P ( -20.0°C, 80.0°C )
From -18.0 to18.0°F, ProNem Mini PMI-P ( -4.0°F,176.0°F )
0..10V 0..20mAZ Zor
2..10V 4..20mAZ Zor
(1) (2)
(2)(1)
It is valid, if the device type 0/2...10V
It is valid, if the device type 0/4...20mA
Z
Z
Humidity Sensor Input.
Humidity Sensor Input .
(1)
(2)
i
Analogue input range is determined with this parameter.
Note : parameter ProNem Mini PMI- type device are not observed.P
HysteresisParameterforHumidity(Default=1)
From 1 to 10 for Humidity Sensor (0%RH, 100%RH)
From 0.1to 10.0 for Humidity Sensor (0.0%RH,100.0%RH)
In ON/OFF control algorithm,
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude
around set value changes according to
controlled system. For reducing oscillation
period of temperature value, a threshold
zone is formed below or around set value
and this zone is named hysteresis.
Humidity
ON
OFF
Humidity
Control
Output
Set
hhSt
Time
hhSt
Time
Maximum Humidity Set Value Parameter (Default = Maximum Value of Device Scale)
This parameter value can be
adjusted from minimum humidity set value parameter to maximum value of the
device scale.
Humidity set value can not be greater than this value.
Minimum Humidity Set Value Parameter (Default = Minimum Value of Device Scale)
set value can not be lower than this value. This parameter value can be adjusted
from minimum value of device scale to maximum set value parameter
Humidity
Humidity
Sensor Offset Parameter ( Default = 0.0 )Humidity
From -10 to 10 for Humidity Sensor (0%RH, 100%RH)
From -10.0 to 10.0 for Humidity Sensor (0.0%RH,100.0%RH)
Timeof AutomaticEggTrayRotator (Default=00:00)
Thisparametervaluecanbeadjustedform00:00to99:00minute/second.
Repeatcycleof AutomaticEggTrayRotator (Default=00:00)
Thisparametervaluecanbeadjustedform00:00to24:00hour/minute.
Alarm Output Function Selection Parameter ( Default = 0 )
Alarm is inactive.
Alarm-Temperature sensor failures.
Alarm-Humidity sensor failures.
Alarm-Temperature or Temperature sensor failures.
Alarm-Humidity or Humidity sensor failures.
Alarm-Temperature sensor failures or Humidity sensor failures.
Alarm-Temperature or Humidity or Temperature sensor failures or Humidity
sensor failures.
Note : if parameter value is 3 or 6 , , , , , or parameters are
observed.
Note : if parameter value is 4 or 6 , , , , , or parameters are
observed.
Temperature Alarm Set Parameter
Thisparametervaluecanbeprogrammedbetweentemperatureminimumalarmset
parameterandtemperaturealarmsetmaximum parameter.
( Default = 50.0 °C )
Temperature Alarm Function Selection Parameter ( Default = 0 )
Process High alarm selected.
Process Low alarm selected.
Deviation Band alarm selected.
Deviation Range alarm selected.
Alarm Set Maximum Parameter ( Default = Maximum Value of Device Scale)
if temperature alarm is active, this parameter value can be adjusted from temperature
alarm set value parameter to maximum value of the device scale.
Alarm Set Minimum Parameter (Default = Minimum Value of Device Scale)
if temperature alarm is active, this parameter value can be adjusted from minimum value of
device scale to temperature alarm set maximum parameter value.
Temperature Alarm Parameter
This parameter value can be adjusted form 0 to %50 of the device scale.
Hysteresis ( Default = 0)
Temperature AlarmOnDelayTimeParameter
Temperature AlarmOnDelay Timecanbedefinedwiththisparameter.Itcanbe
adjustedfrom0to99minutes.
(Default=0)
Temperature Alarm Delay After Power On Parameter
It can be adjusted from 0 to 99 minutes.
( Default = 0)
When power is first applied to the device, this time delay must be expired for activation of
temperature alarm.
Process High alarm selected.
Process Low alarm selected.
Deviation Band alarm selected.
Deviation Range alarm selected.
Humidity AlarmSetParameter
Thisparametervaluecanbeprogrammedbetweenhumidityminimumalarmset
parameterandhumidityalarmsetmaximum parameter.
(Default=50)
Humidity Set Minimum Parameter(Default =Minimum Valueof Device Scale)
if humidity alarm is active, this parameter value can be adjusted from minimum value of
device scale to humidty alarm set maximum parameter value.
Alarm
Humidity Alarm Parameter
This parameter value can be adjusted form 0 to %50 of the device scale.
Hysteresis ( Default = 0)
Buzzer ActiveTime
Ifbuzzerfunctionselectionparameter
Buzzeractivetimecanbedefinewiththisparameter.Itcanbeadjustedfrom1to99
minutes.Whenthisparameteris1,ifdecrementbuttonispressed, isobserved.In
thisconditionbuzzerisactivetillbuzzersilencebuttonispressed.
(Default= )
value=0,thisparameterisnotobserved.
Note-1: External Fuse is recommended
WHITE
YELLOW
BROWN
GREEN
ProNemMini
PMI-P
BLACK
Shield
Note: (Black)pinmustbeconnectedtonumber10(GND)oftheterminalblock.Shield
P/N:ESM-3722-5.2.5.0.1/01.01/1.0.0.0
7 8
a
3x3A@250V V
5A @250VV
L
230 V ±15%
50/60Hz -1.5VA
V
2 3 41
ALARM
PTC
5 6
ENGINE
HEAT
L N NNN N
0/4-20mA
HUM.
HUM.
INPUT
TEMP.
INPUT
9 10 11
P/N:ESM-3722-5.6.6.0.1/01.01/1.6.6.0
7 8 9 10
a
3x3A@250V V
5A @250VV
L
230 V ±15%
50/60Hz-1.5VA
V
2 3 41
ALARM
5 6
ENGINE
11 12
HEAT
L N NNN N
HUM.
ProNemMiniPMI-P
WHITE
BROWN
YELLOW
GREEN
VCC
GND
SCL
SDA
5.1 ProgrammingModeParameterList
Decimal Seperator Enabling Parameter ( Default = 0 )
None.
Only Temperature parameters with decimal seperator.
TemperatureUnitSelectionParameter (Default=0)
°C selected.
°F selected.
Only Humidity parameters with decimal seperator.
Only Temperature and Humidity parameters with decimal seperator.
Note : When value of or parameters are changed , the values of , , , ,
, , , , , , , , , , , , and parameters
should be changed accordingly.
0..10V veya 0..20mAZ Z
2..10V veya 4..20mAZ Z
Temperature SensorScaleSelectionParameter(Default=0)
(1) (2)
(2)(1)
Analogue(T inputrangeisdeterminedwiththisparameter.emperature)
Temperature
or
or
SensorScaleLowLimitParameter:(Default=0)
It can be adjusted from -1999 to ( -1). At this value analogue input becomes;
If =0,accordingtothedevicetype0V 0mA
If =1,accordingtothedevicetype2V 4mA
Z Z
Z Z
(1) (2)
(1) (2)
Temperature
or
SensorScaleHighLimitParameter:(Default=100)
Itcanbeadjustedfrom( +1)to9999. Atthisvalueanalogueinputbecomes;
According to the device type 10V 20mAZ Z
(1) (2)
Note : , parameters are shown, if the Temperature sensor analogue input type is selected .
Note : , and parameters are shown, if the Temperature sensor input type
( ) is selected.
analogue
0/2..10V or 0/4..20mA
ESM-3722
ü ü
ESM-3722
ESM-3722
ü ü
ESM-3722
ü
ESM-3722 ESM-3722
ü
Programming Mode Accessing Password
It is used for accessing to programming mode. It can be adjusted from 0 to 9999. If it is 0,
password is not entered for accessing to the parameters. When the password screen is not
set as “12” , If the user enters ‘12’ in password screen and parameters are
accessed and they can changed.
( Default = 0 )