Emko IPERTU Medium Lite Manual

Emko Ikke kategoriseret IPERTU Medium Lite

Læs gratis den danske manual til Emko IPERTU Medium Lite (8 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Emko IPERTU Medium Lite, eller vil du spørge andre brugere om produktet?

Side 1/8
1 ENG IPERTU-MPL_MPPXXX 02 V01_04 25
Medium CPU (PLC) Module with Digital & Analog Input and
Transistor & Analog Output
General Specicaons :
* Program Memory Area : 196K
* pieces Digital Input ( NPN / PNP) 9
* According to module type; 2 or 4 analog input channels
* Analog input types (each analog input can be set in dierent
type individually) : V, mA
* ON/OFF kontrol, PID kontrol, AutoTune, SelfTune
* pieces Digital Outpu (Acve High) 6 t
* According to module type; 4 or 2 analog output (V/mA)
* Ethernet 10/100 Mbit
Easy access via the Internet with WEB QUICK CONNECT
Module access via Web Browser with IPERTU SCADA
* Modbus RTU communicaon protocol with RS232
* Modbus RTU communicaon protocol with RS485
* USB - Device
* Modular connecon (up to 16 extension modules)
* Led indicators:
- RUN, USB, RS- 485
- Acve digital input, digital & analog output led indicators
- Analog input error led led indicators
MPL3P1- - - - 02 20 03 01_1
MPL3P1- - - - 02 21 03 03_1
Technical Specicaons
Module Type
MPL3P1- - - - 02 20 03 01
MPL3P1- - - - 02 21 03 03
Supply Voltage
24 VDC ± %20 (19,2 VDC - 28,8 VDC)
Power Consumpon
4,5W
5,5W
Communicaon
RS- -485 Modbus RTU, Ethernet 232, RS
USB Device
Mini USB, USB 2.0
Non-Volale Memory
4K, 10 years permanent memory life
Execuon Speed
LD instrucon duraon : 30nsec/instrucon
MOV instrucon duraon : 80nsec/instruciton
I/O refresh duraon : ~300μsec/module
Peripheral service duraon : ~10μsec/cycle
Digital Inputs
Number of Inputs
9
Type
NPN / PNP
Nominal Input Volt.
24 VDC
Acve Level
Low Level < 7 VDC High Level > 10 VDC ,
Input Resistance
> 5,9 kΩ
Maximum Current
6 mA
Maximum frequency
20 kHz (3 x A/B channel encoder connecon)
Detecon Speed
Filter opon between 1-500 msec
Analog Inputs
Number of Inputs
4 x V / mA
2 x V / mA
Input Sensor Type
V, mA
Measurement Range
/ Resoluon
V > 0 ...... +2V / 1 mV, 0 ...... +5V / 1 mV,
0 ...... +10V / 1 mV, 2 ...... +10V / 1 mV
> mA 0 ...... , +20mA / 1 µA 4 ...... +20mA / 1 µA
ADC resoluon
15 bit
Input Impedance
Voltage type inputs mA type inputs > 48 KΩ, > 47 Ω
Overall accuracy
% 0.2 (full scale)
Response me
Per channel 150ms
150ms
2 ENG IPERTU-MPL_MPPXXX 02 V01_04 25
Average funcon
The aritmec average of the last read measurements according to the specied average
number of samples
Fault detecons
1- short circuit, 2- sensor break, 3- over range
Digital Outputs
Number of Outputs
6
Digital Output Current
0,3 A (one channel), 1,8 A (total COM current)
Transistor Power
External 24VDC supply must be connected
Maximum Frequency
6 channel 10 KHz PWM and PTO ,
6 channel 100 , PWM and PTO KHz
Protecon
-
Analog Outputs
Number of Outputs
2 x V / mA
4 x V / mA
Output range
0-10V or 0-20mA (only one tpe can be selected in the same me)
Overall accuracy
% 0.5 (in the full scale measurement range)
Output Resistance
For voltage output > 5kΩ, for current output < 440Ω
Response me
~200 msec
Led Indicators
RUN
“Green” in RUN mode “Red” in STOP mode “Yellow”, , in RESET mode
Flashes 1 sec in case of any error (low voltage, bus communicaon error)
Flashes 0.2 sec ON / 2 sec OFF if the device in Soware Boot Mode
Ethernet
Yellow : Speed, Green : Link
USB
Always ON if the USB cable plugged, ashes during data transfer
RS485
Flashes during Modbus data transfer
Digital Input
ON when input acve, OFF otherwise
Analog Input
Always OFF in normal operaon
Always ON in case of fault detecon (Sensor Break, Short Circuit, Over Range)
Flashes during PID auto-tune or self-tune process ongoing
Transistor Output
ON when output acve, OFF otherwise
Analog Output
ON when output acve, OFF otherwise
Operaon / Storage Environment
Operaon Temp.
- . 10°. .+60° C
Storage Temperature
- . 20°. .+70° C
Isolaon
* There is no isolaon between Power Input and RS485 & USB
* 1000 VAC between Power Input and Digital Inputs
* 500 VAC between Analog Input and Power Input
* There is no isolaon between Analog Inputs
* 1000 VAC between Power Input and Digital Outputs
* 500 VAC between Analog Output and Power Input
* There is no isolaon between Analog Outputs
Volale Memory Area Map
Address Name
Address Range
Address Type
Denion
X
0 127
BOOL
Logic Input Memory Area
Y
0 127
BOOL
Logic Output Memory Area
AI
0 31
WORD
Analog Input Memory Area
AO
0 31
WORD
Analog Output Memory Area
M
0 7999
8000 8191-
BOOL
Bit Memory Area
Specic Bit Memory Area
D
0 7999
8000 8191-
WORD
Data Memory Area
Specic Data Memory Area
S
0 1023
BOOL
Status Bits
CV
0 199
200 255
WORD
DWORD
Counter Memory Area
TV
0 255
WORD
Timer Memory Area
C
0 255
BOOL
Counter Bit Memory Area
T
0 255
BOOL
Timer Bit Memory Area


Produkt Specifikationer

Mærke: Emko
Kategori: Ikke kategoriseret
Model: IPERTU Medium Lite

Har du brug for hjælp?

Hvis du har brug for hjælp til Emko IPERTU Medium Lite stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Emko Manualer

Emko

Emko ECO PRO+ Manual

25 Juni 2025
Emko

Emko EAOM-11.2 Manual

29 December 2024
Emko

Emko EPM-7790 Manual

29 December 2024
Emko

Emko EPM-3790 Manual

29 December 2024
Emko

Emko ATS-10 Manual

29 December 2024
Emko

Emko ESM-3712-H Manual

29 December 2024
Emko

Emko EZM-9920 Manual

29 December 2024
Emko

Emko proop7L Manual

31 August 2024
Emko

Emko IPERTU Supply Manual

31 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer