Læs gratis den danske manual til EtherWAN OttoE 10H (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 2 anmeldelser. Har du et spørgsmål om EtherWAN OttoE 10H, eller vil du spørge andre brugere om produktet?

Side 1/2
W70G- TG103HQ1 Page 1
Copyright 2023 EtherWAN Systems, Inc. All Rights Reserved 10/11/2023
Installation Guide
OttoE TG103(H) Series | Unmanaged PoE Ethernet Switch
Unpacking
Open the carton and unpack the items. Your package should include:
One OttoE TG103(H) switch. Note that the (H) indicates hardened models.
If any items are missing or damaged, notify your EtherWAN representative. If
possible, save the carton and packing material in case you need to ship or store
the switch in the future.
Equipment Needed
Appropriate cables for data ports. To prevent damage to the switch from
electrical surges, it is recommended to use STP (Shielded twisted pair) cabling
with a minimum rating of cat5e.
Appropriate SFP modules for SFP ports
Select a Location
Installation: Place the device on the DIN rail from above using the slot. Push
the front of the device toward the mounting surface until it audibly snaps into
place.
Choose a dry area with an ambient temperature between -10 and 60ºC (-14
and 140ºF).
Choose a dry area with an ambient temperature between -40°C to 75°C (-
40°F to 167°F) for H models.
Keep away from heat sources, sunlight, warm air exhausts, hot-air vents, and
heaters.
Be sure there is adequate airflow.
For indoor use or in a sealed enclosure.
Designed in accordance with pollution degree 2.
Connect to the Data Ports
Depending on the model, your switch can have the following ports:
TG103(H)-0800
8 Gigabit PoE ports
TG103(H)-0802
8 Gigabit PoE ports + 2 100/1G SFP ports
TG103(H)-0442
4 Gigabit PoE ports + 4 Gigabit TX ports + 2 100/1G SFP
ports
Connect Power
The switch has two power inputs. Only one power input is required to operate
the switch. Connect the supply voltage to start up the device via the terminal
block.
Power rating:
PoE 30 Watts per port: 5257 VDC, 5.47-4.99 A
PoE 90 Watts per port: 5457 VDC, 5.17-4.99 A
Total PoE max.270W.
The power input specification complies with the requirements of SELV (Safety
Extra Low Voltage), and the power supply should comply with UL 61010-1
and UL 61010-2-201.
Terminal Block
The switch provides two power inputs on a 52-57VDC terminal block.
Pin
State
Description
Power 1
+
52-57VDC
-
Power Ground
Power 2
+
52-57VDC
-
Power Ground
Earth Terminal
Relay Output Rating
0.5A @ 48VDC
Relay Output Alarm
The switch provides a relay output contact. The relay is used to indicate a user-
defined power redundancy failure. The current is 0.5A@48VDC at Normally Open
or Normally Closed.
Relay Contact
Normally Open
Normally Closed
No power
Open
Closed
Normal
Closed
Open
Abnormal
Open
Closed
LED Indicators
TG103(H)-0442 TG103(H)-0802 TG103(H)-0800
LED
Color
Status
L/A (Link/Active)
Green
On: Link active
Off: No link
Flashing: Data transmission
PWR 1 & 2
Green
On: Power on
Off: Power off
Alarm
Red
On: Error - power redundancy
failure
Off: No power error condition
PoE
Amber
On: Powered Device connected
Off: Powered Device disconnected
Power-Up Sequence
When the switch is powering up:
All Link/ACT LEDs blink momentarily.
The Power 1, 2 LEDs light up and stay lit.
LEDs for every port connected to a device will flash, as the switch conducts a
brief Power On Self-Test (POST).
Quality of Service (QoS)
The QoS feature is automatically activated when the switch is running. Priority
mapping is handled according to the following tables:
CoS priority
(802.1p)
7, 6
5, 4
3, 2
1, 0
DSCP priority
59, 55
47, 46, 43
27
Other
Queues
3
2
1
0
WFQ
Highest
Priority
Secondary
Priority
16
1
EtherNet/IP: UDP 2222 (Queue 2)
Profinet Ether type: 0x8892 (Queue 2)
DIP Switch Settings
There is a 10-pin DIP switch for enabling the Watchdog (WDG) function.
When the DIP switch for a port is set to ON, the WDG function will be enabled
after the TG103(H) has been powered on for 10 minutes to give powered devices
time to boot. Every 30 seconds WDG will detect whether the packets from a
powered device are being received or not. If no packet is received after 30
seconds, connected ports with the DIP switch set to ON will be restarted (other
ports are not disturbed). If a packet is received in the 25th second, then the 30
seconds interval will be restarted.
If DIP switch 9 (EXT) is set to ON, the WDG function will be enabled after 5
minutes instead of 10 minutes after the switch powers on, to accommodate
faster booting powered devices.


Produkt Specifikationer

Mærke: EtherWAN
Kategori: Ikke kategoriseret
Model: OttoE 10H

Har du brug for hjælp?

Hvis du har brug for hjælp til EtherWAN OttoE 10H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret EtherWAN Manualer

EtherWAN

EtherWAN OttoE 10H Manual

5 November 2025
EtherWAN

EtherWAN EX42905 Manual

4 November 2025
EtherWAN

EtherWAN ED3575 Manual

4 November 2025
EtherWAN

EtherWAN AiR PACE CL Manual

4 November 2025
EtherWAN

EtherWAN EX41922 Manual

3 November 2025
EtherWAN

EtherWAN SmartE Manual

3 November 2025
EtherWAN

EtherWAN PD1041 Manual

1 November 2025
EtherWAN

EtherWAN EX94000 Manual

1 November 2025
EtherWAN

EtherWAN EX87000 Manual

1 November 2025
EtherWAN

EtherWAN ED3541 Manual

1 November 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Intermatic

Intermatic WP1250MXD Manual

5 November 2025
INIU

INIU P63-P1 Manual

5 November 2025
D'Addario

D'Addario PW-XPND-01 Manual

5 November 2025
DS18

DS18 VOC8PRO Manual

5 November 2025
Icron

Icron Rover 2850 Manual

5 November 2025
Amaran

Amaran Peak Manual

5 November 2025
WesAudio

WesAudio Timbre Manual

5 November 2025