Extron XPA U 1002 Manual

Extron Modtager XPA U 1002

Læs gratis den danske manual til Extron XPA U 1002 (3 sider) i kategorien Modtager. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Extron XPA U 1002, eller vil du spørge andre brugere om produktet?

Side 1/3
1
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
XPA Ultra Series Audio Power Amplifiers • Setup Guide
(XPA U 358, XPA U 358-70V, XPA U 358-100V, XPA U 358C-70V, XPA U 358C-100V, XPA U 1004,
XPA U 1004-70V, XPA U 1004-100V, XPA U 1004C-70V, XPA U 1004C-100V, XPA U 1002,
XPA U 1002-70V, XPA U 1002-100V)
WARNING: Installation and service must be performed by experienced, professional installers only.
AVERTISSEMENT : L’installation et l’entretien doivent être effectués par des installateurs professionnels
expérimentés.
power ampliers. All references are to the XPA Ultra Series User Guide which can be found on www.extron.com.
Step 1 — Powering Down Equipment
Be sure that power to the amplier is turned off rst.
NOTE: Adjust the audio level to (full attenuation) prior to powering the amplier in Step 7 on page3.=
Turn off all other equipment and disconnect the power cables. Verify that the amplier is disconnected from the power source
before proceeding.
Step 2 — Mounting and Applications
Rack Mounting
The XPA Ultra Series ampliers can be rack mounted using one of the following methods.
NOTE: See the XPA Ultra Series User Guide for instructions on mounting to a rack shelf.
Rack Ear Mounting (Single Unit)
The XPA Ultra Series ampliers ship with a set of rack ears so the half rack-width ampliers can be installed in a full rack-width
space.
Mount the amplifier with the rack ears as follows:
1. If feet were installed on the bottom of the amplier, remove them.
2. Attach the included rack ears to the sides of the amplier with the four provided #6 machine screws (
1
in the gure below).
3. Insert the amplier into the rack, align the holes in the rack ears with the holes on the rack.
4. Secure the amplier to the rack using four provided 10-32 x 3/4” screws (
2
in the gure below).
e
XPA U 1004 SERIES
1234
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER AMPLIFIERS
1
e
XPA U 1004 SERIES
1234
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER AMPLIFIERS
2
2
Bridge Plate Rack Mounting (Side-by-Side Units)
The XPA Ultra Series ampliers ship with a bridge plate connector for connecting two XPA Ultra Series ampliers together to form
a full rack-width unit.
Connect and mount two XPA Ultra Series amplifiers as follows:
1. If feet were installed on the bottom of the ampliers, remove them.
2. Position the two ampliers upside down and next to each other (see the gure below).
3. Use the bridge plate connector and four provided #4 machine screws to connect the two ampliers together (
1
in the gure
below).
4. Attach the two short rack ears to the ampliers with four provided #6 machine screws (
2
in the gure below).
5. Insert the ampliers into the rack, align the holes in the rack ears with the holes on the rack.
6. Secure the amplier to the rack using four provided 10-32 x 3/4” screws (
3
in the gure below).
e
XPA U 1
0
04 SERIES
1234
OVER
TEMP LIMITER/PROTECT
S
IGNAL
POWER AMPLIFIERS
e
XPA U 1004 SERIES
1234
OVER
TEMP L
IMITER/PR OTECT
S
IGNAL
P
OWER A MPLIFIER
S
Mounting
screws (4)
2
1
e
XPA U 1004 SERIE
1 2 3 4
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER AMPLIFIER
ES
RS
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP LIMITER/PROTECT
SIGNAL
POWER
AMPL IFIERS
3
Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplier.
An over temp indicator LED on the front panel of the amplier lights red
whenever the recommended operating temperature has been exceeded.
To reduce the chances of an over temp condition, the XPA Ultra ampliers
should be arranged in a rack environment so the environment around the
amplier does not reach or exceed +122 °F (+50 °C). No more than four
stacks of XPA Ultra ampliers should be arranged one-on-top-of-the-other
in a rack without an open space between the stacks (see the gure to the
right).
XPA Ultra ampliers can also be arranged above or below another
non-XPA Ultra device. In this case, the environment around the amplier
should not reach or exceed +122 °F (+50 °C).
Step 3 — Captive Screw Audio Cable Wiring
Wire the source output to the amplier 3.5 mm captive screw input connectors as shown in the following illustrations.
Balanced Stereo Input
Tip
Ring
Tip
Ring
Slee
ves
L R
Unbalanced Stereo Input
Tip
Sleeve
Sleeve
Tip
L R
Do not tin
the wires!
Balanced Dual Mono Input
Tip
Ring
Slee (s)ve
Tip
Ring
L R
Unbalanced Dual Mono Input
Tip
Sleeve
Tip
Sleeve
L R
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space


Produkt Specifikationer

Mærke: Extron
Kategori: Modtager
Model: XPA U 1002

Har du brug for hjælp?

Hvis du har brug for hjælp til Extron XPA U 1002 stil et spørgsmål nedenfor, og andre brugere vil svare dig