Testing Summary
Samsung Active II Tablet Dual USB Docking Station
(7160-1368)
Summary of Tests Performed at Gamber-Johnson
Test Description Test Parameters
Vibration –
Operational
Test date: May, 2019
MIL-STD-810G, Method 514.6, Procedure 1, Category 4, per Figure
514.6C-1. Test duration is one hour along three mutually orthogonal
axes – not simultaneously (3 hours total).
• Unit is unlocked
Vibration –
Non-Operational
(Minimum Integrity)
Test date: April, 2019
MIL-STD-810G, Method 514.6, Category 24, per Figure 514.6E-1. Test
duration is one hour along three mutually orthogonal axes – not
simultaneously.
• Unit is unlocked
Functional Shock -
Non-Operational
Test date: April, 2019
MIL-STD-810G, Method 516.6, Procedure 1, 3 positive and 3 negative
pulses each axis (vertical, longitudinal and transverse), 18 pulses
• 20G, 11ms half sine
• Unit is unlocked
Mechanical Shock
Safety -
Non-Operational
Test date: April, 2019
MIL-STD-810G, Method 516.6, Procedure 1, 3 positive and 3 negative
pulses each axis (vertical, longitudinal and transverse), 18 pulses
• 40G, 11ms half sine
• Unit is unlocked
Electrostatic
Discharge –
Operational
Test date: April 2019
ISO 10605, Section 8, Table C.2, Category 2 – Direct Air Discharge
Summary of Tests Performed at Independent Facility
Test Description Test Parameters
Humidity
Test date: April 2019
MIL-STD 810G, Method 507.5, Procedure ll, Aggravated, Table 507.5-
l
• Ten 24-hour cycles, temperature varied from 30ᵒC to 60ᵒC to
30°C at constant 95% relative humidity.
Low Temperature:
Operational
Test date: April 2019
MIL-STD 810G, Method 502.5, Procedure ll
• -20ᵒC Operating, 24-hour duration
Low Temperature:
Storage
Test date: April 2019
MIL-STD 810G, Method 502.5, Procedure l
• -40ᵒC Non-Operating, 24-hour duration