Læs gratis den danske manual til Greisinger GMH 2710K (8 sider) i kategorien Termometer. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Greisinger GMH 2710K, eller vil du spørge andre brugere om produktet?

Side 1/8
H .0.01.6C-0581
GREISINGER electronic GmbH
D - 93128 Regenstauf, Hans-Sachs-Straße 26
Phone: 09402 / 9383-0, fax: 09402 / 9383-33, eMail: info@greisinger.de
as of version V1.0 GMH 2710 /GMH2710-K
Operating Manual Pt100 Precision Thermometer
WEEE-Reg.-Nr. DE 93889386
H81.0.01.6C-05 Operating Manual GMH 2710 / GMH 2710-K page 2 of 8
_____________________________________________________ _____________________________________________________________________________
Index
1 DESIGNATED USE ....................................................................................................................................2
2 GENERAL NOTE .......................................................................................................................................2
3 SAFETY REQUIREMENTS ......................................................................................................................3
4 DISPLAY AND CONTROL ELEMENTS ................................................................................................3
4.1 D .................................................................................................................................3 ISPLAY ELEMENTS
4.2 C ................................................................................................................................3 ONTROL ELEMENTS
4.3 P - .............................................................................................................................................4 OP UP CLIP
5 START OF OPERATION ..........................................................................................................................4
6 BASICS .........................................................................................................................................................5
7 CONFIGURATION OF THE DEVICE ....................................................................................................5
8 ADJUSTMENT ............................................................................................................................................6
9 REPLACING BATTERIES........................................................................................................................6
10 ERROR AND SYSTEM MESSAGES ...................................................................................................7
11 ACCURACY INSPECTION: ADJUSTMENT /UPDATE SERVICE ................................................7
12 DISPOSAL NOTES..................................................................................................................................7
13 TECHNICAL DATA................................................................................................................................7
1 Designated Use
The device is measuring temperature in °C or °F.
The safety requirements (see below) have to be observed.
The device must be used only according to its intended purpose and under suitable conditions.
Use the device carefully and according to its technical data (do not throw it, strike it, …).
2 General Note
Read this document carefully and get used to the operation of the device before you use it. Keep
this document within reach for consulting in case of doubt.
If the device is stored at temperatures above 50°C the battery has to be removed from the device.
NOTE : We recommend taking out battery if device is not used for a longer period of time.
Risk of leakage!