LIMITED WARRANTY
HAWS warrants that this specic product is guaranteed against defective material or poor
workmanship for a period of . HAWS liability under this one year from d e of shipmentat
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
or part thereof, which shall appear to the Company upon inspection to be of defective
material or not of rst class workman ip, provided that claim is made in writing to Haws sh
within a reasonable period after receipt of the product. Where claims for defects are made,
the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS
will not be liable for the cost of repairs, alterations or replacements, or for any expense
connected therewith made by the owner or his agents, except upon written authority from
HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective
materials or poor workmanship, except for replacements, as provided above. Buyer agrees
that Haws has made no other warranties either expressed or implied in addition to those
above stated, except that of title with respect to any of the products or equipment sold
hereunder and that HAWS shall not be liable for general, special, or consequential damages
claimed to arise under the contract of s ale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and m are adhered to. The units also must be used for the aintenance instructions provided
purpose for which they were intended. This product is intended to supplement rst-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will pr ent serious injury or the aggravation of existing or prior ev
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED
OR GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNIC SUPPORT:AL 1- - -5612 800 766
FOR CUSTOMER SERVICE: 1-888- - 97 640 42
10/20 Model 8315CTFP (120V) & 8 5CTFP.220V Page 2 of 13 31
RECOMMENDED TOOLS SUPPLIES: &
Pipe wrench (both with teeth smooth jaws) es and
Power drill with Phillips bit (preferr ), or Phillips screwdriver (preferably ratcheting) #2 ed #2
Adjustable wrench (or a s ndard wrench set up 7/8 ) ta
7/32" hex key
Level
Three (3) rust-resistant anchors (3/8” diameter)
Pipe joint sealant (Loctite # 7 recommended) PST 56
Silicone caulking (Dow Corning 832 recommended)
Stepladder
LOCATION OF UNIT:
The Model 8315CTFP (120V) & 8 5CTFP.220V Emergency Shower Eye/Face Wash should be installed in 31
close proximity to potential accident areas. It should be clearly identied, free from obstructio , and easy to ns
access.
Suitable for use in Class 1, Division 2 Group B,C,& D areas.
Temperature rating T6 (85°C).
ELECTRICAL SUPPLY: D ing potentially freezing periods, ensure that unit is connected to a continuous ur
power supply.
e rical power required for standard heat traced unit is 120 VAC. Average power MODEL 8315CTFP: El ct
consumption a °F (10°C) ambient temperature is 1 watts. Maximum without lighting is 130 wattst 50 10 .
Connection at input junction box is 3/4” NPT.
Electrical power required for standard heat traced unit is 220 VAC. Average MODEL 8315CTFP.220V:
power consumption at 50° (10°C) ambient temperature is 1 watts. Maximum without lighting is 130 wattsF 10 .
Connection at input junction box is 3/4" NPT.
WATER SUPPLY: ater supply must be freez protected. W e
The minimum recommended line is 1- -90 psi (2-6 ATM) o pressure. 1/4” IPS with 30 wing
An inlet lter is recommended where sediment or mineral content is a problem.
Main inlet connection is 1-1/4” IPS.
Optional SP121 auxi ary outlet plumbing 1-1/4 li is IPS.
MAINTENANCE:
Allow eye/face wash piping to drain out completely be re replacing eye/face wash dust cover. fo
In freezing conditions, wipe eye/face wash head and dust cover dry after each use to prevent unwanted ice
buildup.
During regula testing, also verify these items: r
o Verify that both the eye/face wash and the showe are able to drain completely. r
o Verify that the st cover is intact and rmly in place. du
Optional SP158.15 Freeze Protection Valve is a eld serviceable item; refer to its manual for more
information.
WARNING Fire and shock hazards must use a ground fault electrical protection device (30mA GFEPD) for :
heat trace. Electrical fault currents may be insucient to trip a conventional circuit breaker.


Produkt Specifikationer

Mærke: Haws
Kategori: Bruseanlæg
Model: 8315CTFP

Har du brug for hjælp?

Hvis du har brug for hjælp til Haws 8315CTFP stil et spørgsmål nedenfor, og andre brugere vil svare dig




Bruseanlæg Haws Manualer

Haws

Haws 8356WCC Manual

24 August 2024
Haws

Haws 8315CTFP Manual

24 August 2024
Haws

Haws 8300.158 Manual

24 August 2024
Haws

Haws 7501 Manual

24 August 2024
Haws

Haws 7360B Manual

24 August 2024
Haws

Haws 7501T Manual

24 August 2024

Bruseanlæg Manualer

Nyeste Bruseanlæg Manualer

Gustavsberg

Gustavsberg Round Manual

30 December 2025
Hansgrohe

Hansgrohe 04201000 Manual

11 December 2024
Juno

Juno BeBa_26010 Manual

2 Oktober 2024
Schütte

Schütte Florenz Manual

21 September 2024
Schütte

Schütte Haiti Manual

8 September 2024