Heatmiser DS1-EL Manual


Læs gratis den danske manual til Heatmiser DS1-EL (4 sider) i kategorien Termostater. Denne vejledning er vurderet som hjælpsom af 6 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 3.5 anmeldelser. Har du et spørgsmål om Heatmiser DS1-EL, eller vil du spørge andre brugere om produktet?

Side 1/4
Wiring Diagram
The Heatmiser DS1-EL dial type thermostat is designed
specically for electric underoor heating.
This thermostat incorporates the following functions;
• Adjustable Switching Dierential
• Digital LCD
• 230v AC, 13A Switching
Introduction
Model: DS1-EL
RCD
MAINS SUPPL
Y
L N
MATTING OR WIRE
FlOOR PROBE
DS1-EL
Want More Information?
Call our support team on:
+44 (0)1254 669090
Or view technical specications
directly on our website:
www.heatmiser.com
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, TURN OFF THE POWER TO THE
HEATING SYSTEM.
This dial thermostat is designed to be surface mounted.
1. Separate the front part of the thermostat by unscrewing securing screws on the
bottom face of the thermostat.
2. Mark 2 hole positions on the wall using the backplate as a positioning template. Drill at
the marked positions and insert a wall plug in to each hole.
3. Terminate the thermostat as per wiring diagram and screw the DS1-EL back plate to the
back box.
4. Reconnect the thermostat front plate and insert the securing screws.
Installation
PDF FAQ
In normal mode, the display shows the actual room temperature. To change the set point,
rotate the dial until the digital LCD displays the new set temperature.
Setting The Temperature
Display Icons
The Heatmiser DS1-EL has a lock facility. To lock the thermostat, press and hold down the
dial for 10 seconds. You will see a lock symbol appear. To unlock, repeat the steps above.
Heating ON Keypad Locked
The Heatmiser DS1-EL oers 1, 2 and 3°C switching dierential.
With a 1°C switching dierential the heating will switch on 1°C below the set
temperature and will turn o when the set temperature is reached.
A 2°C will turn the heating on 2°C below the set temperature.
3°C will switch the heating on 3°C below the set temperature.
To set the dierential, set the DIP switches according to the table below.
This setting is only required when the sensor option is set to Air and Floor mode.
The setting is used to protect the oor surface from overheating.
The oor temperature limit can be set to 20, 28 or 40°C.
To set the required oor limit temperature, set the DIP switches according to the table.
The thermostat has three modes of operation. Select the desired mode,
and set the DIP switches according to the table.
The DIP switches can be accessed from the back of thermostat.
Air Sensor: Uses the built in air sensor only.
Air Sensor & Floor Limiting Sensor: Uses the built in air sensor but also uses the
remote oor sensor to ensure the oor temperature doesn’t overheat.
Floor Sensor: Uses the remote oor sensor only.
Lock Facility
Switching DierentialFloor Temperature Limit
Sensor Option
1 2
2 °C Switching
28°C
Air & Floor
2
2
2
Switch 1 ON and Switch 2 OFF
Switch 5 ON and Switch 6 OFF
Switch 3 ON and Switch 4 OFF
22
33
11
Should the oor temperature be achieved (even if the desired room temperature has
not) the heating will turn o. The Heat Active Icon will ash in this case.


Produkt Specifikationer

Mærke: Heatmiser
Kategori: Termostater
Model: DS1-EL

Har du brug for hjælp?

Hvis du har brug for hjælp til Heatmiser DS1-EL stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostater Heatmiser Manualer

Heatmiser

Heatmiser PRT Manual

13 Januar 2025
Heatmiser

Heatmiser Touch-N Manual

13 Oktober 2024
Heatmiser

Heatmiser PRT-TS Manual

10 Oktober 2024
Heatmiser

Heatmiser PRTHW-N Manual

6 August 2024
Heatmiser

Heatmiser DS1-EL Manual

6 August 2024
Heatmiser

Heatmiser DT-W Manual

7 Juli 2024

Termostater Manualer

Nyeste Termostater Manualer