Honeywell RPLS730B1000 Manual

Honeywell Skifte RPLS730B1000

Læs gratis den danske manual til Honeywell RPLS730B1000 (12 sider) i kategorien Skifte. Denne vejledning er vurderet som hjælpsom af 57 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 29 anmeldelser. Har du et spørgsmål om Honeywell RPLS730B1000, eller vil du spørge andre brugere om produktet?

Side 1/12
INSTALLATION AND USER GUIDE
69-2457EFS-05
RPLS730B / RPLS731B
Programmable Wall Switch
APPLICATIONS
The RPLS730B / RPLS731B programmable wall switch has been designed to
control lightings and motors:
INSTALLATION
NOTE: This switch cannot be used if there are not at least 2 white wires joined
by a connector inside the electrical box.
1. Cut power at the circuit breaker to avoid electric shock.
2. Remove the existing switch.
3. Install the new switch as shown in the diagram below.
4. Apply power at the circuit breaker.
Load type Maximum load Examples
Resistive load 2400 W (20 A @ 120 V) incandescent lights
halogen lights
block heater
Inductive load 2400 W (20 A @ 120 V) fluorescent lights
compact fluorescent lights (CFL)
sodium lamps
electronic ballasts
Motor 1 hp pool filter pumps
fans
M38497
120 VAC (line)
blue (load)
white (neutral)
Load
black (line)
RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
69-2457EFS—05 2
POWER-ON
1. Pry the switch door open from the bottom
using a small screwdriver.
2. Ensure the ON/OFF selector is set to ON.
3. 0:00Reset the switch using a paper clip. will
flash.
If the display is blank:
Ensure the ON/OFF selector is properly
engaged in the ON position. Push it to the right
using a small screwdriver.
At first power-up after the installation, the
screen of the switch may be blank or dim, or
become so when you turn the light on. However,
during that time, the switch is fully functional. Wait 2 minutes for the
switch’s built-in battery to be sufficiently charged and the screen will
return to its normal contrast.
SETTING THE CLOCK
NOTE: The switch displays the time in 24-hour format by default or follow-
ing a reset.
1. To change to 12-hour format (or vice versa), proceed as follows:
Press one of the control buttons to ensure the MAN or AUTO
indicator is displayed.
Press the MIN and HOUR buttons simultaneously and briefly (0:00
display = 24-hour, 12:00 display = 12-hour).
2. Set the time using the HOUR and MIN buttons. If you have selected
the 12-hour format, ensure that PM appears on the screen when an
afternoon time is displayed.
3. Set the day using the DAY button.
4. Press one of the control buttons or close the switch door to return to
normal operation.
SELECTING THE OPERATING MODE
The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO). To switch mode, press the switch door for 3 seconds.
Manual mode
The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode ( ) and state (MAN ON or OFF) are displayed.
Automatic mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed. To temporarily
override the programmed schedule, briefly press the
switch door. The new state (ON or OFF) will flash to show
that this state is temporary. The override remains in effect
until you press the switch door again or until the beginning of the next
program.
M38498
Reset
Control (4)
On/Off selector
M38499


Produkt Specifikationer

Mærke: Honeywell
Kategori: Skifte
Model: RPLS730B1000

Har du brug for hjælp?

Hvis du har brug for hjælp til Honeywell RPLS730B1000 stil et spørgsmål nedenfor, og andre brugere vil svare dig