Læs gratis den danske manual til Honeywell TL8100 (12 sider) i kategorien Termostat. Denne vejledning er vurderet som hjælpsom af 39 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 20 anmeldelser. Har du et spørgsmål om Honeywell TL8100, eller vil du spørge andre brugere om produktet?

Side 1/12
USER GUIDE
69-2018EFS-01
TL8100
7 DAY PROGRAMMABLE HYDRONIC THERMOSTAT
1. DESCRIPTION
This thermostat can be used to control the following heating
systems:
gas, oil or electric systems
hot water heating
hot air system with no fan control
millivolt system (e.g., gas fireplace)
electric heating up to 1200 W @ 240 V max.
2. TEMPERATURE DISPLAY
AND SETTING
Setpoint Temperature
The thermostat normally
displays the measured
ambient temperature. To view
the setpoint temperature,
briefly press either of the
buttons. The setpoint
temperature will appear for 5
seconds.
To adjust the setpoint, press one of the buttons until the
desired temperature is displayed.
Preset Temperatures
The thermostat has 3 preset temperatures:
To use a preset temperature:
Press the corresponding button ( , or ). The
temperature and the corresponding icon will be displayed.
To change a preset temperature:
1. Set the desired temperature using the buttons.
2. Press and hold the corresponding button ( , or )
until the icon is displayed on the screen (approximately
3 seconds).
Programming
buttons
Temperature
preset buttons
Temperature
adjustment
buttons
Time and day
Temperature
Mode and preset
temperature
indicators
Heating
indicator
Low-battery
indicator
Appears during the
setpoint display
Preset temperature Default value
Comfort temperature 68°F (20°C)
Economy temperature 64°F (18°C)
Vacation temperature 50°F (10°C)
TL8100
69-2018EFS—01 2
3. SET THE TIME AND DAY
1. Set the time, using the HOUR and MINUTE buttons.
2. Set the day, using the DAY button.
4. AUTOMATIC MODE
Use automatic mode if you want the
thermostat to follow the programmed
schedule. The thermostat will switch from the
Comfort temperature to the Economy
temperature, or vice versa according to the
schedule.
To use the automatic mode, press the
Manual/Auto button repeatedly until
appears on the screen.
Temporary Bypass
You can bypass the temperature setpoint of the current period
when the thermostat is in Automatic mode.
To do so, press one of button until the desired
temperature is displayed or select a preset temperature by
pressing the corresponding button ( , or ).
You can cancel the bypass, by pressing the Manual/Auto
button twice, before it cancels automatically at the start of the
next period.
Schedule Programming
You can program up to 4 periods in a day. The Comfort
temperaure is used in periods 1 and 3 and the Economy
temperature is used in periods 2 and 4. The start time of each
period can be different for each day of the week.
For each day, enter the time you wake up (period 1), the time
you leave for work (period 2), the time you return home
(period 3) and the time you go to sleep (period 4):
NOTE: For periods 1 and 3, set the start time earlier by at
least 15 minutes for every 2°F (1°C) that the temper-
ature needs to rise. For example, if you lower the
temperature by 6°F (3°C) at night and you wake up
at 7:00 a.m., set period 1 to 6:15 a.m.
Press Program to enter the programming mode. The
thermostat will display MO
(Monday) and PROG 1
(period
1).
To select another day, press Day.
NOTE: To select all 7 days, hold Day for 3 seconds. When
all 7 days are selected, the start time of the period being
displayed will be the same every day.
To select another period, press Program.
Press Hour and Min to set the start time for the displayed
period. If you want the thermostat to skip a period, press
Clear, the time display of the displayed period becomes
--:--.
Press Manual/Auto to exit.
NOTE: If you do not press any button for 60 seconds, the
thermostat will automatically exit the programming
mode and save any changes made.
5. MANUAL MODE
In manual mode, the programmed schedule is
not followed. Use this mode if you wish to set
the temperature manually or maintain the
same temperature all the time.
To use the manual mode, press the Manual/
Auto button repeatedly until the hand icon
appears on the screen.
Press one of buttons until the desired
temperature is displayed or select a preset
temperature by pressing the corresponding button ( , or
).
6. VACATION MODE
In Vacation mode, the thermostat is set to the
Vacation temperature. There are 2 ways to
place the thermostat in Vacation mode.
Press on the thermostat.
From the remote control system or home
automation system.
NOTE: The Vacation mode can only be
deactivated remotely if it has been
activated remotely.
7. BATTERY REPLACEMENT
An icon appears when the
batteries must be
replaced. The icon
remains on the display for
60 days. Afterwards, the
thermostat will cut power
to the heating system.
The time and programming
are saved for the first 15
seconds when the
batteries are removed.
Period Associated Temperature Time
1 Comfort Wake up
2 Economy Leave home
3 Comfort Return home
4 Economy Sleep