Læs gratis den danske manual til JUNG A5232SMO (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 30 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 15.5 anmeldelser. Har du et spørgsmål om JUNG A5232SMO, eller vil du spørge andre brugere om produktet?

Side 1/4
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection
Blinds Management
Centre plate with anti lock-out function
Art. No. : ..5232..
Centre plate with anti lock-out function and sensor connection
Art. No. : ..5232 S..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
(4) Status LED
3 Function
Intended use
- Operation of electrically-driven blinds, shutters and awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Status LED
- Lock-out protection
- The individual moving time from the upper end position is storable
1/4
32550723
J:0082550723 16.05.2014
Additional functions for the cover with sensor connection
- Evaluation of a sun sensor
- Brightness threshold adjustable
- Automatic recognition of an outdoor sensor during the first sensor run
Sun protection function for cover with sensor evaluation
The connection of a sun sensor enables automatic shading when it is very bright outside. The
brightness threshold that controls the sun protection can be adjusted on the cover. If the
measured brightness exceeds the predefined brightness threshold for more than 2 minutes, the
Venetian blind moves downwards. The previously stored individual moving time is executed for
an outdoor sensor. The stop position is determined by the sun sensor for an indoor sensor.
iThe sun protection function is only activated if the Venetian blind has been moved to the
upper end position and the control has deactivated automatically after 2 minutes. Each
manual operation deactivates the sun protection.
If the brightness threshold is fallen short of for more than 15 minutes, the Venetian blind moves
back to the upper end position.
4 Operation
Moving the Venetian blind
oPress top or bottom of cover for longer than one second.
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
Adjusting the slats
oPress top or bottom of cover for shorter than one second.
The slat position changes in the desired direction for as long as the button is pressed.
Activating lock-out protection
The lock-out protection prevents the Venetian blind from automatically moving down
unintentionally. Shutting down on site via the sensors or extensions is disabled.
oPress top of cover for longer than 4 seconds.
Status LED is illuminated. Venetian blind moves to the upper end position, the lock-out
protection is activated.
Deactivating lock-out protection
oPress top button briefly.
Status LED goes out.
The lock-out protection is deactivated.
iAfter a power failure, the lock-out protection is deactivated.
Saving individual moving time
If a Venetian blind should not move to the lower end position "ventilation function" or an outdoor
sensor is used, a shorter moving time can be stored. A time between 0.5 seconds and 2
minutes can be stored.
oPress cover over entire surface for longer than 4 seconds.
The Status LED flashes. The Venetian blind moves automatically to the upper end position.
oKeep the cover pressed in the direction until the Venetian blind is in the desired position.o
oRelease cover.
Venetian blind stops.
oPress cover over entire surface for at least 1 second to store the moving time.
- Or -
oPress cover or to discard the moving time.o n
The storage mode is exited automatically and the LED ceases to be illuminated.
2/4
32550723
J:0082550723 16.05.2014
Blinds Management
Centre plate with anti lock-out function, Centre plate with anti lock-out
function and sensor connection


Produkt Specifikationer

Mærke: JUNG
Kategori: Ikke kategoriseret
Model: A5232SMO

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG A5232SMO stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret JUNG Manualer

JUNG

JUNG RCDME2022 Manual

30 Juli 2025
JUNG

JUNG RCD2023 Manual

30 Juli 2025
JUNG

JUNG RCD2021 Manual

30 Juli 2025
JUNG

JUNG RCD2044 Manual

30 Juli 2025
JUNG

JUNG RCD2022 Manual

30 Juli 2025
JUNG

JUNG RCDME2044 Manual

30 Juli 2025
JUNG

JUNG 1711 DE Manual

30 Juli 2025
JUNG

JUNG MA1000AD4 Manual

20 Juli 2025
JUNG

JUNG SM1608 Manual

19 Juli 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

LG

LG LPC-M155X Manual

4 August 2025
LG

LG LX-U150 Manual

4 August 2025
LG

LG LM-U555X Manual

4 August 2025
LG

LG LM-M1030G Manual

4 August 2025
LG

LG DK7711N Manual

4 August 2025
Dual

Dual C 824 Manual

4 August 2025
LG

LG FFH-515A Manual

4 August 2025
LG

LG DKE574XB Manual

4 August 2025
Hikoki

Hikoki H70SD Manual

4 August 2025