Læs gratis den danske manual til JUNG A5232ST (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 20 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 10.5 anmeldelser. Har du et spørgsmål om JUNG A5232ST, eller vil du spørge andre brugere om produktet?

Side 1/5
Centre plate with timer function "standard"
Blinds Management
Centre plate with timer function "standard"
Art. No. : .. 5232 ST ..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
1/5
32537613
J:0082537613 21.05.2014
Figure 2: Display and buttons
(4) Current weekday
(5) Operating mode: Manual or Automatic
(6) Current time of day
(7) Buttons
3 Function
Intended use
- Manual and time-controlled operation of electrically-driven Venetian blinds, shutters and
awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Each Up and Down travelling time can be saved for weekdays and for the weekend
- Travelling times programmed at the factory
- Current time of day can be saved as travelling time
- Automatic and manual operation
- Operation via 4 buttons
- Indication of the current time
- Programming without flush-mounted insert possible
- Power reserve > 6 hours
Behaviour after a mains voltage failure
Voltage failure less than 6 hours
- Time and switching times are retained
- Missed travelling times are not performed later
Voltage failure greater than 6 hours
- Time flashes and the manual operating mode is active.
- Time and weekday must be set again
- The travelling times are reset to default setting
Travelling times with the default setting
Movement direction Weekdays Time
up Mo - Fr 7:00
Down Mo - Fr 20:00
2/5
32537613
J:0082537613 21.05.2014
Blinds Management
Centre plate with timer function "standard"


Produkt Specifikationer

Mærke: JUNG
Kategori: Ikke kategoriseret
Model: A5232ST

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG A5232ST stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret JUNG Manualer

JUNG

JUNG 1710DE Manual

3 Juni 2025
JUNG

JUNG MALS1133 Manual

31 December 2025
JUNG

JUNG MAAL1133 Manual

14 December 2024
JUNG

JUNG MAGO1193 Manual

10 December 2024
JUNG

JUNG MAA1193 Manual

10 December 2024
JUNG

JUNG MACD1193WW Manual

10 December 2024
JUNG

JUNG WS10D Manual

10 December 2024
JUNG

JUNG AL1561.07F Manual

10 December 2024
JUNG

JUNG 1745DSTE Manual

10 December 2024
JUNG

JUNG MALS1193 Manual

10 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer