Centre plate with timer function "standard"
Blinds Management
Centre plate with timer function "standard"
Art. No. : .. 5232 ST ..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
1/5
32537613
J:0082537613 21.05.2014
Figure 2: Display and buttons
(4) Current weekday
(5) Operating mode: Manual or Automatic
(6) Current time of day
(7) Buttons
3 Function
Intended use
- Manual and time-controlled operation of electrically-driven Venetian blinds, shutters and
awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Each Up and Down travelling time can be saved for weekdays and for the weekend
- Travelling times programmed at the factory
- Current time of day can be saved as travelling time
- Automatic and manual operation
- Operation via 4 buttons
- Indication of the current time
- Programming without flush-mounted insert possible
- Power reserve > 6 hours
Behaviour after a mains voltage failure
Voltage failure less than 6 hours
- Time and switching times are retained
- Missed travelling times are not performed later
Voltage failure greater than 6 hours
- Time flashes and the manual operating mode is active.
- Time and weekday must be set again
- The travelling times are reset to default setting
Travelling times with the default setting
Movement direction Weekdays Time
up Mo - Fr 7:00
Down Mo - Fr 20:00