JUNG GO1751BT Manual


Læs gratis den danske manual til JUNG GO1751BT (10 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 6 anmeldelser. Har du et spørgsmål om JUNG GO1751BT, eller vil du spørge andre brugere om produktet?

Side 1/10
LB management
LB management
LB management
LB managementLB management
Universal timer Bluetooth
Universal timer Bluetooth
Universal timer Bluetooth
Universal timer Bluetooth
Universal timer BluetoothUniversal timer Bluetooth
Art. no.: ..1751BT..
Operating instructions
Operating instructions
Operating instructions
Operating instructionsOperating instructions
1
1
1
11 Safety instructions
Safety instructions
Safety instructions
Safety instructionsSafety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load. In
Danger of electric shock. Always disconnect before carrying out work on the device or load. In
Danger of electric shock. Always disconnect before carrying out work on the device or load. In
Danger of electric shock. Always disconnect before carrying out work on the device or load. InDanger of electric shock. Always disconnect before carrying out work on the device or load. In
so doing, take all the circuit breakers into account, which support dangerous voltages to the
so doing, take all the circuit breakers into account, which support dangerous voltages to the
so doing, take all the circuit breakers into account, which support dangerous voltages to the
so doing, take all the circuit breakers into account, which support dangerous voltages to theso doing, take all the circuit breakers into account, which support dangerous voltages to the
device and or load.
device and or load.
device and or load.
device and or load.device and or load.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.These instructions are an integral part of the product, and must remain with the end customer.
2
2
2
22 Device components
Device components
Device components
Device componentsDevice components
Figure1: Device components
(1) Insert
(2) Frame
(3a) Blind/shutter up / light on, brighter
(3b) Blind/shutter down / light off, darker
(4a) Disabling function
(4b) = activate Bluetooth coupling, Ʃ
Activating / deactivating automatic operation
(5) Function LED
Red = Disabling function active
Orange = Automatic operation deactivated
Blue = Bluetooth connection active
Flashing blue = Bluetooth coupling mode active
Flashing blue three times = Time is not set
(6) Status LED
Green = Blind/shutter activated / light switched on
Red = Error message or reset
Priorities for the LED display:
- Red LED before green or orange LED
- Blue LED before red LED
1 / 10
32598103 02.10.2019
J0082598103
LB management
LB management
LB management
LB managementLB management
Universal timer Bluetooth
3
3
3
33 Function
Function
Function
Function Function
Intended use
Intended use
Intended use
Intended useIntended use
Manual and time-controlled operation of e.g. Venetian blinds, shutters, awnings, lighting or
fans
Operation and programming with mobile end device (smartphone or tablet) via Bluetooth
Operation of switching, dimming or Venetian blind insert or 3-wire extension from LB man-
agement
Product characteristics
Product characteristics
Product characteristics
Product characteristicsProduct characteristics
Functions directly on the cover
Operation of blinds/shutters and lighting
Activating / deactivating the disabling function
Activating / deactivating automatic operation
Running time and ventilation position of the blind/shutter can be saved
Switch-on brightness or switch on to last brightness with dimming insert can be saved
Night mode
Functions via Bluetooth app
Operation of blinds/shutters and lighting with status feedback
Display of current blind/shutter position, dimming position or switching state
Programming of up to 40 individual switching times
Venetian blind and slat positions or switching and dimming values can be saved at any
switching time
Possible to copy switching times from other devices
Switching at sunrise and/or before sunset (Astro function)
Astro time through position fixing
Astro time shift can be set for each switching time
Automatic summer/winter time changeover, can be switched off
Random function
Automatic date and time update when connecting with smartphone
Code request for protection for time programs and configuration possible
Save a ventilation position, blind/shutter running time, slat change-over time and change-
over-time for direction change
Switch to inverse operation for Venetian blind inserts possible
Maximum brightness and minimum brightness for dimming insert can be set
Sun protection and twilight functions are possible via optional brightness sensor
Behaviour after a mains voltage failure
Behaviour after a mains voltage failure
Behaviour after a mains voltage failure
Behaviour after a mains voltage failureBehaviour after a mains voltage failure
Voltage failure less than power reserve
All data and settings are preserved
Missed switching times are not performed later
Voltage failure greater than power reserve
The blue LED flashes three times repeatedly until the time is automatically updated when
connected with the app
No switching operations are executed
Switching times are preserved
Default setting
Default setting
Default setting
Default settingDefault setting
Switching times on a Venetian blind insert:
ƞ 07:00, Mo - Thu
Ɵ 21:00, Mo - Thu
ƞ 07:00, Fr
2 / 10
32598103 02.10.2019
J0082598103


Produkt Specifikationer

Mærke: JUNG
Kategori: Ikke kategoriseret
Model: GO1751BT

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG GO1751BT stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret JUNG Manualer

JUNG

JUNG 1710DE Manual

3 Juni 2025
JUNG

JUNG MALS1133 Manual

31 December 2025
JUNG

JUNG MAAL1133 Manual

14 December 2024
JUNG

JUNG MAGO1193 Manual

10 December 2024
JUNG

JUNG MAA1193 Manual

10 December 2024
JUNG

JUNG MACD1193WW Manual

10 December 2024
JUNG

JUNG WS10D Manual

10 December 2024
JUNG

JUNG AL1561.07F Manual

10 December 2024
JUNG

JUNG 1745DSTE Manual

10 December 2024
JUNG

JUNG MALS1193 Manual

10 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer