Læs gratis den danske manual til JUNG TR-SREG (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 3.6 stjerner ud af 2 anmeldelser. Har du et spørgsmål om JUNG TR-SREG, eller vil du spørge andre brugere om produktet?

Side 1/2
Sunlight/dusk sensor
Use the suction pad to attach the
sunlight/dusk sensor (Diagram
) to the
window pane.
The sunshade function allows you to automa-
tically roll the blinds down when the bright-
anywhere on the window pane to determine
the blinds limiting position.
Application: sunshade for computer work-
stations, sunshade for flowers on windows
sills or in greenhouses etc.
The dusk function allows you to automatical-
ly roll the blinds down when the brightness
falls below a set value. The blinds will be rol-
led down to their bottom limiting position.
You can place the dusk sensor anywhere on
the window pane.
Application: rolling down the blinds when
darkness falls. Only available in conjunction
with the timer cover.
0 - 20 mm
20 mm
Technical data
Sunlight/dusk sensor
Max. sensitivity of
photodiode: approx.
850 nm for λ
Max. amount: 1
Temperature range: 30 °C to +70 °C
Type of protection: IP 54
Glass-break sensor
Glass-break sensors (Diagram
) monitor flat
glass surfaces within a radius of up to 2 m
(depending on glass thickness, frame, putty
etc.). Mechanical vibrations that are too weak
to reach the sensor will not be detected (e.g.
scratching the glass). Window panes with
uneven surfaces (textured or wired glass) and
laminated glass panes muffle vibrations too
much and may therefore not be monitored by
means of broken glass sensors.
Glass-break sensors are very sensitive
devices. Knocking on it or any other improper
treatment may destroy them.
Use a suitable glue (e.g. Loctite Glass-to-Metal
Glue Kit) to attach the glass-break sensor to the
window pane.
Observe the specified distances to the win-
dow frame (Diagram
).
The blinds will be rolled down to their bottom
limiting position when the glass gets broken.
Application: weather protection if the glass
gets broken.
Technical data
Glass-break sensor
Contact: 1-pole break contact
Switching capacity: max. 350 mW
Transitory resistance:
Idle mode max. 30 Ohm
Alert mode min. 1 MOhm
Alert signal duration: approx. 0.5 5 s
Supply line: LIYY 2 x 0.14 mm
2
Temperature range: 30°C to +70°C
Type of protection: IP 67
Max. amount: 10 (series-connected)
Coupling
Connect the coupling (Diagram
) to the 3-
pole terminal located on the cover with sen-
sor connector or on the insert. The coupling
has two female connectors into which you
plug the male sensor connectors of sunlight/
dusk sensor and/or broken glass sensor.
Technical data
Coupling
Number of sensors: max. 1 sunlight/dusk
to be connected to sensor
the plug-in and max. 1 broken
connector glass sensor
Note
Glass-break sensors may not be used
together with the converter (wind sensor).
The wind protection function via the satellite
input (blind is rolled up) is disabled after
glass breakage, the blind or slats remain
closed.
Sunlight/dusk sensor
Glass-break sensor
Coupling
Decoupling relay
A 93
Decoupling relay TR-S with separate mains
connection
Application example:
Decoupling relays are required if you wish to
use one single blinds controller to operate
several drive units because it is not possible
to connect electrical shutter drives in parallel.
JUNG TR-S can be installed in any 60 mm
wall or junction box.
a = 3 x 1.5 mm
2
, 230 V ~
b = 4 x 1.5 mm
2
, 230 V ~
c = 5 x 1.5 mm
2
, 230 V ~
AZ = junction box
Mains
230 V ~
AZ TR-S
a
c
c
b
b
Motor
Motor
Ref.-No. 32 SD
Ref.-No. 32 G
Ref.-No. 32 K
Ref.-No. TR-S, TR-S REG
A 94
Wiring diagrams
Decoupling relay
Ref.-No. TR-S, TR-S REG
Technical data
Mains AC 230 V ~, 50 Hz
Control AC 230 V ~, 50 Hz
Capacity 4A, AC 230 V ~,
cos ϕ0,8
Operation
The TR-S or the TR-S REG is used for the
simultanous operation of two drives.
For the control all mechanical blinds push-
buttons as well as the motor control inserts
can be used.
Mounting
The TR-S can be installed in a standard
junction wall box.
Mounting
The TR-S REG is a panel mounted device for
a 35 mm DIN rail.
85 mm
85 mm
39 mm
51 mm
51 mm
TR-S REG
TR-S
Wiring example
for groupcontrol
M2
M2
M1
M1
4
3
2
1
10
9
8
7
6
5
Z
Z
N
L1
10
9
8
7
6
5
4
3
2
1
M1
M2
L1
M1
M2
N
Z
Z
Example: 232 ME TR-S terminal TR-S terminal


Produkt Specifikationer

Mærke: JUNG
Kategori: Ikke kategoriseret
Model: TR-SREG
Vekselstrømsindgangsspænding: 230 V
Vekselstrømsindgangsfrekvens: 50 Hz
Produktfarve: Copper colour, Green

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG TR-SREG stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret JUNG Manualer

JUNG

JUNG TR-SREG Manual

18 Juni 2025
JUNG

JUNG 1792HTBT Manual

18 Juni 2025
JUNG

JUNG AS 5232 F Manual

18 Juni 2025
JUNG

JUNG 804.28 G Manual

17 Juni 2025
JUNG

JUNG 1710DE Manual

3 Juni 2025
JUNG

JUNG MALS1133 Manual

31 December 2025
JUNG

JUNG MAAL1133 Manual

14 December 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer