Læs gratis den danske manual til Little Giant 513273 (1 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.2 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Little Giant 513273, eller vil du spørge andre brugere om produktet?

Side 1/1
ASSEMBLY INSTRUCTIONS FOR
PREMIUM SIMPLEX SYSTEMS
PRE-PACKAGED UNIT:
Verify all parts with basin and cover assemblies are received intact. The
flanges provided will allow the following discharge/vent combinations to be
used: 3 discharge/2 vent, or a 2” discharge/2 vent, depending on cover
configuration. Please note that basin should be backfilled with cover secured
on basin to ensure that cover holes will align properly.
1. Remove bolts and washers in cover and set aside.
2. Remove gasket material from hardware kit and place material around
circumference of basin inside of bolt circle.
3. Place the pump on a flat surface and install the discharge pipe in the
4. Install float switch 4” above discharge of pump with a 3-1/2” tether length.
Float switch should be installed in a manner that will not allow it to contact
the pump or side of basin during operation. Refer to float switch instruction
manual for alternative settings. Place the pump in the basin in the torque
stops.
5. To install the cover, pull the pump and float cords through the smallest hole
in the cover. Place the cover on the basin, making sure the discharge pipe
is through the proper hole in the cover. (Holes are labeled on bottom of
cover.) Secure the lid to the basin using the bolts and washers provided.
Place the larger, square-cut O-ring on discharge pipe, beveled edge down.
Install flange and tighten bolts. Place the remaining O-ring in the bottom of
the vent flange with beveled edge down. Install flange and tighten bolts.
6. Pull the slack out of the cords and install them through the grommet 1–2
inches above the cover. Press the grommet in the hole in the cover.
7. Install a 2” vent pipe by threading it on the vent flange. Make sure the flange
bolts are tight.
LITTLE GIANT
SEWAGE ACCESSORIES
& INSTRUCTIONS FOR
TYPICAL INSTALLATION
Figure 1 - Typical Installation
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
Phone: 405-947-2511 • Fax: 405-947-8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
REPLACEMENT PARTS LIST
ITEM PART NO. DESCRIPTION QTY.
1
113093 Basin, 24” x 24” 1
113095 Basin, 20” x 30” 1
2
113057 1Cover, 1-piece, slip-fit flanges, foam, 3V2D, 2V3D, or 2V2D
11318000 Cover, 1-piece, bolt-on flanges, foam, 2V2D 1
113181 Cover, 1-piece, bolt-on flanges, foam, 2V3D 1
113182 Cover, 1-piece, bolt-on flanges, foam, 3V2D 1
113183 Cover, 1-piece, bolt-on flanges, foam, 3V3D 1
113184 Cover, 2-piece, bolt-on flanges, foam, 2V2D 1
113185 Cover, 2-piece, bolt-on flanges, foam, 2V3D 1
113186 Cover, 2-piece, bolt-on flanges, foam, 3V2D 1
113187 Cover, 2-piece, bolt-on flanges, foam, 3V3D 1
2A
113214 Discharge flange kit, 2” 1
113216 Discharge flange kit, 3” 1
2B 113215 Vent flange kit, 2” (threaded) 1
2C 925024 Grommet, 2” pipe 1
2D 113341 Grommet, 3” pipe 1
2E 113418 Grommet, reducer 3” to 2” pipe 1
2F N/A Grommet, 2-hole 1
3
113423 Discharge pipe, 2” 1
113424 Discharge pipe, 3” 1
4
940022 Swing check valve, 2” 1
940023 Swing check valve, 3” 1
940026 Swing check/ball valve combo, 2” 1
5
513288 HWAB tank alert, indoor only (not shown) 1
513273 303HWXT tank alert, indoor/outdoor (not shown) 1
Form 998264 - 12/01/2010
© 2006 Franklin Electric Co., Inc.
Little Giant® is a registered trademark of Franklin Electric Co., Inc.
PRE-ASSEMBLED UNIT:
The pre-assembled unit is furnished fully assembled and ready for installation.
Remove check valve or ball/check valve from discharge pipe and re-install as
shown on typical installation. For best performance of check valves CAUTION:
when handling solids, install in a horizontal position or at an angle of not more
than 45°. Do not install check valve in a vertical position, as solids may settle in
valve and prevent opening on start-up. Remove the cord from the vent hole and
install the vent pipe. See Figure 1 to complete a typical installation.
To test the unit, plug the unit in and run water into the basin until the unit
switches on. If the unit does not operate, refer to the troubleshooting information
in the instructions for the pump.


Produkt Specifikationer

Mærke: Little Giant
Kategori: Pumpe
Model: 513273

Har du brug for hjælp?

Hvis du har brug for hjælp til Little Giant 513273 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Little Giant Manualer

Pumpe Manualer

Nyeste Pumpe Manualer

ProFlo

ProFlo PF92305 Manual

15 December 2025
ProFlo

ProFlo PF92370 Manual

15 December 2025
Liberty Pumps

Liberty Pumps CSP-457 Manual

11 December 2025
ProFlo

ProFlo PF93511 Manual

11 December 2025
ProFlo

ProFlo PF92342 Manual

11 December 2025
Liberty Pumps

Liberty Pumps LE41A Manual

11 December 2025
Vevor

Vevor 2KQ-3G Manual

2 December 2025
Vevor

Vevor TL-A5102 Manual

2 December 2025