Læs gratis den danske manual til Lowrance EP-60R Fuel Flow (48 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 51 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 26 anmeldelser. Har du et spørgsmål om Lowrance EP-60R Fuel Flow, eller vil du spørge andre brugere om produktet?

Side 1/48
1
Pub. 988-0154-432
EP-60R Fuel Flow
Electronic Sensor
Installation, Configuration and Calibration Instructions
This document shows how to install an EP-60R Fuel Flow sensor and
how to connect it to a NMEA 2000® network. It also provides
instructions on how to configure and calibrate your fuel flow sensor
with Lowrance digital gauges (LMF-200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the
National Marine Electronics Association (NMEA) for use in boats.
Lowrance has introduced a line of products that can communicate over
a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000
certified or certification is pending.
Caution:
Installing LowranceNET NMEA 2000 devices is significantly
different from installing earlier Lowrance components without
NMEA 2000 features. You should read all of the installation
instructions before proceeding. You should decide where to
install all components before drilling any holes in your vessel.
The EP-60R Fuel Flow sensor.
NMEA 2000
red connector
Fuel Flow
module
2
Some sonar or GPS display units may require a software upgrade to
display NMEA 2000 data correctly. For free software upgrades or
additional information on the LowranceNet NMEA 2000® network
system, visit our web site, www.lowrance.com.
The EP-60R consists of a red cable connector and the sensor module.
The sensor module contains a turbine to measure fuel flow and
electronics which convert flow data to the NMEA 2000 data format.
The cable length from the connector to the smart module is 10 feet (3
meters). The sensor is designed to work with gasoline only.
WARNING:
Do not use this sensor with diesel engine fuel systems.
The EP-60R is designed only for gasoline engines.
This sensor has been optimized to measure flow rates between 0.6 to 45
gallons (US) per hour, but it will operate at flow rates outside that
range. The sensor will add 0.5 PSI of back pressure on the fuel system
with a flow rate of 20 gallons per hour. At the rate of 40 gallons per
hour, the back pressure will be 1 PSI.
The EP-60R Fuel Flow, like the other LowranceNet Electronic Probe
(EP) sensors, is designed for use with a NMEA 2000 network. Your
sensor, however, is also compatible with LowranceNet blue connector
networks. It can be added to a blue connector network by using a
female red to female blue adapter cable. Your sensor MUST be
connected to a NMEA 2000 network or it WILL NOT function.
The NMEA 2000 female red to female Blue adapter cable allows users
to add red connector devices to a blue connector network.
Tools and Supplies
Your EP sensor packs with a T connector needed to attach it to a
LowranceNET NMEA 2000 network. If this is the first sensor you are
connecting, you may also need to purchase of a LowranceNET Node
Kit.