Læs gratis den danske manual til Milwaukee 2212-20 (11 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 46 personer og har en gennemsnitlig bedømmelse på 3.8 stjerner ud af 23.5 anmeldelser. Har du et spørgsmål om Milwaukee 2212-20, eller vil du spørge andre brugere om produktet?

Side 1/11
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
AUTO VOLTAGE/CONTINUITY TESTER AND AUTO VOLTAGE/CONTINUITY
TESTER W/ RESISTANCE
TESTEUR AUTOMATIQUE DE TENSION/CONTINUITÉ ET TESTEUR
AUTOMATIQUE DE TENSION/CONTINUITÉ AVEC RÉSISTANCE
PROBADOR AUTOMÁTICO DE VOLTAJE/CONTINUIDAD Y PROBADOR
AUTOMÁTICO DE VOLTAJE/CONTINUIDAD CON RESISTENCIA
Cat. No.
No de cat.
2212-20
2213-20
23
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to follow
the warnings and instructions may result in electric shock, re and/or serious injury, as well as
instrument damage and/or damage to the equipment being tested. Save these instructions - This
operators manual contains important safety and operating instructions for the MILWAUKEE
Electrical Testers. Before using, read this operator’s manual and all labels on the Electrical Testers.
DANGER
Never make measurement on a circuit in which voltage over 600V rms exists. Use only leads
rated 600V CAT IV or better.
Do not apply more than the rated voltage, as marked on the Tester, between terminals or
between any terminal and earth ground.
Do not attempt to make measurement in the presence of ammable gases. Otherwise, the use
of the instrument may cause sparking, which can lead to an explosion.
Never attempt to use the instrument if its surface or your hand is wet.
Do not exceed the maximum allowable input of any measuring range.
Only test on unenergized circuits unless absolutely necessary.
Check tool functionality on a known circuit rst. Never assume tool is working. Assume circuits
are live until they can be proven de-energized.
Never open the Battery cover during a measurement.
Do not ground yourself while measuring. Avoid body contact with earthed or grounded sur-
faces such as pipes, radiators, ranges and refrigerators.
This instrument is to be used only in its intended applications or conditions. Otherwise, the instru-
ment's safety functions may not work, resulting in serious personal injury and instrument damage.
To reduce the risk of injury from shock and arc blasts, always wear personal protective
equipment where live conductors are exposed.
WARNING
Never attempt to make measurement if any abnormal conditions, such as broken case and
exposed metal parts are found on the instrument.
Comply with local and national safety requirements when working in hazardous locations.
Keep ngers behind the guards and away from test lead tips during measurements.
Do not change the slide switch position (Cat. No. 2213-20) while the test leads are being con-
nected.
Verify proper operation on a known source before use or taking action as a result of the in-
dication of the instrument.
Do not install substitute parts or make any modi cation to the instrument. For repair, return
the tool to a factory Service/Sales Support Branch or authorized service station.
Do not try to replace the batteries if the surface of the instrument is wet.
Disconnect all the cords and cables from the object under test and power off the instrument
before opening the Battery Cover for Battery replacement.
This tool is designed to be powered by 2- AAA batteries properly inserted in the Milwaukee
Electrical Tester. Do not use with any other voltage or power supply.
Install battery according to polarity (+ and –) diagrams.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
Properly dispose of used batteries.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be ejected from the battery, avoid contact. If contact
accidentally occurs, ush with water. If liquid contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation or burns.
CAUTION
Set the Slide Switch (Cat. No. 2213-20) to an appropriate position before starting measurement.
Disconnect test leads from test points before changing the slide switch function (Cat. No.
2213-20).
Never connect to a source of voltage with the tester OFF or slide switch position in Ω (Cat.
No. 2213-20).
Firmly insert the test leads.
Do not expose the instrument to the direct sun, high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating temperature is within 0ºC and 50ºC.
Keep away from excess dust and water.
Be sure to power off the instrument after use. When the instrument will not be in use for a long
period, place it in storage after removing the batteries.
Use a damp cloth or neutral detergent for cleaning the instrument. Do not use abrasives or
solvents.
GENERAL SPECIFICATIONS
Maximum voltage between
any terminal and earth ground
600V CAT IV
Temperature Operating: 0°C to 50°C (32°F to 122°F)
Storage: -10°C to 60 °C (-14°F to 140°F)
Operating Altitude 2,000 m
Drop Test 1 m
Battery 2 AAA, NEDA 24 A,IEC LR03
Battery Life Approx. 20 Hours normal use
Safety Compliances UL/CSA/IEC/EN 61010-1 3rd Edition and IEC/EN 61010-2-033 1st
Edition (Meter), UL/CSA/IEC/EN 61010-031 1st Ed + A1 (Probes).
Measurement Category IV, 600V, Pollution Degree II,
EMC EN 61326-1.
Certi cations cULus, CE
Function Range Resolution Accuracy
Voltage AC 5 - 600 V 1 V ±(3.0% + 5 dgt)
Voltage DC 2 - 199.9 V 0.1 V ±(3.0% + 5 dgt)
200 - 600 V 1 V ±(3.0% + 5 dgt)
Resistance 2 - 20 k 0.01 k ±(3.0% + 5 dgt) 
Continuity Continuity Buzzer
0 - 20 k
Continuity Buzzer sounds
at 20 k or less
FUNCTIONS
Accuracy specified as ±(% of reading + 5 digits)
* Input impedance AC/DC Voltage : 300 k
* Overload protection:
For 2212-20 - Meter protected for inputs above rated voltage AC/DC 600 V
For 2213-20 - Function Switch at , Meter protected for inputs above rated voltage AC/DC 600 V
Function Switch at , Meter protected for inputs above rated voltage AC/DC 420 V
* Test leads rated for 10A with: measurement time 30 seconds maximum, rest time 20 minutes minimum,
40°C ambient.


Produkt Specifikationer

Mærke: Milwaukee
Kategori: Multimeter
Model: 2212-20

Har du brug for hjælp?

Hvis du har brug for hjælp til Milwaukee 2212-20 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Milwaukee Manualer

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025