Læs gratis den danske manual til Optex AX-350DH MK3 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Optex AX-350DH MK3, eller vil du spørge andre brugere om produktet?

Side 1/4
AX-350DH MK III
AX-650DH MK III
AX-350DH TS
AX-350DH BT
No.59-1073-0 0406-04
FEATURES
CONTENTS
·Multiple beam installation of up to 4 sets
·Simple optical alignment
·High waterproofing property; jet-proof : IP65
·Wide optical alignment range:
±90 degrees horizontally; ±20degrees vertically
*AX-350DH BT:
±60 degrees horizontally; ±45 degrees vertically
·Reduced possibility of false alarms caused by flying
objects
1. INSTALLATION GOOD PRACTICE
2. PARTS IDENTIFICATION
3. NOTES ON INSTALLATION
4. INSTALLATION METHOD
5. TERMINAL CONNECTIONS
6. WIRING
7. OPTICAL ALIGNMENT
8. BEAM INTERRUPTION TIME ADJUSTMENT
9. RE-TRANSMISSION FUNCTION
10. WALK TEST
11. HEATER UNIT HU-2
12. BACK COVER BC-1
13. DIMENSIONS
14. TROUBLESHOOTING
15. SPECIFICATIONS
2
3
3
4
6
7
8
11
11
12
12
13
13
15
16
-1-
INSTALLATION
INSTRUCTIONS
top/bottom unit AND/OR selectable
maximum detection range: 350ft.(100m)
PHOTOELECTRIC DETECTOR
·Digital communication function
·Cross talk prevention function
·Peak Finder Interface (P.F.I ) of Dual Alignment
Level Indicator
·Mode-specific indicator allowing simple and
accurate optical alignment
·Simple beam alignment without the “Beam
Blocking Tool”
·Minimization of light disturbance
·ATPC ( Auto Transmit Power Control )
to optimize the power of beam
Thank you for purchasing our product.Be sure to read the
following installation instructions carefully before beginning
installation.Make sure that the person in charge of system
management stores this manual carefully for maintenance
and management.
model for beam tower, upper and lower unit unit AND/OR selectable
maximum detection range: 350ft.(100m)
maximum detection range: 350ft.(100m)
maximum detection range: 650ft.(200m)
Downloaded from manuals search enginewww.Manualslib.com
-3-
28-39inch(0.7-1m)
23.5 inch(60cm)
39 inch(1m)
2. PARTS IDENTIFICATION
Mounting Plate
Wall Mounting Screw
Holes & Waterproof
Plug (x 4)
Vertical Alignment Dial
Terminals
See 5. “TERMINALon PAGE6.
Horizontal Alignment Dial
View Finder
Cover Lock Screw
Cover
Unit Base
Mounting Screw
(x 4)
Wiring Hole (x 2)
Monitor Jack
Alignment Level Indicator
Unit Base Pole Mounting
Screw Holes &
W a t e r p r o o f
Plug (x 4)
Rubber
Bushing
Rubber Bush Slot
Pole Mounting
Screw Holes &
Waterproof Plug
(x 4)
Hood
Hood
Switch Section
Transmitter
Receiver
Clears the registered address (see 14. “TROUBLESHOOTING” on Page15).
Indicates the registered address by the flickering of the six indicator LEDs for about 10
seconds (see 14. “TROUBLESHOOTING” on Page15).
Switches between high and low the level of infrared beam reception output to the monitor
jack.
Use this switch for multi-level installation (see 7-2. “Master/slave selector switch setting on
Page8).
Switches the interruption time between the four settings (see 8. “BEAM INTERRUPTION TIME
ADJUSTMENT” on Page11).
This switches the detection time for the top unit when AX-350DH TS / BT in the OR mode.
Switch to the AND mode for detection of simultaneous interruption for the top and the bottom
units and to the OR mode for detection of interruption for either unit (see 7-3. “AND/OR
selector switch setting” on Page8).
Turning the switch to ON in the OR mode fixes the interruption time for the bottom unit to one
second (see 8. “BEAM INTERRUPTION TIME ADJUSTMENT” on Page11).
ADDRESS CLEAR:
ADDRESS CHECK:
MONITOR JACK switch:
MASTER/SLAVE switch:
INTERRUPTION TIME switch:
AND/OR switch:
(AX-350DH TS / BT only)
Resets the registered address to the factory settings
(see 14. “TROUBLESHOOTING” on Page15).
Indicates the registered address by the flickering of the six indicator LEDs for about 10 seconds
(see 14. “TROUBLESHOOTING” on Page15).
Switches between high and low the level of infrared beam reception output to the monitor jack.
Use this switch for multiple beam installation (see 7-2. “Master/slave selector switch setting” on Page8).
When more than one detector with the same address is on the alarm line, switches one of them
to prevent malfunction caused by cross talk (see 14. “TROUBLESHOOTING” on Page15).
Switch to the AND mode for detection of simultaneous interruption for the top and the bottom
units and to the OR mode for detection of interruption for either unit (see 7-3. “AND/OR selector
switch setting” on Page8).
ADDRESS CLEAR:
ADDRESS CHECK:
MONITOR JACK switch:
MASTER/SLAVE switch:
FORCED ADDRESS switch:
AND/OR switch:
(AX-350DH TS / BT only)
BOTTOM UNIT INTERRUPTION TIME switch:
(AX-350DH TS / BT only)
3. NOTES ON INSTALLATION
[2] Alignment angle[1] Detection range and installation height [3] Pole mounting
·Pole size should be diameter
1.9inch(48mm).
·The length of the wiring cable out of
the pole should be within 23.5
inch(60cm).
Without AX-350DH BT
180 degrees (± 90 degrees) 40 degrees (± 20 degrees)
AX-350DH BT
120 degrees 60 degrees) 90 degrees (± 45 degrees)
distances between the Receiver and
the Transmitter are listed below:
Horizontally Vertically
35-350ft.(10-100m) : AX-350DH MK III, AX-350DH TS,
AX-350DH BT
65-650ft. (20-200m) : AX-650DH MK III
Normally, the installation height should
be 0.7 1.0m. When OR mode is used,
the installation height of lower beam
should be 15cm from the ground.
For best performance, avoid aligning
detectors at 45 degree angles except
AX-350DH BT.
Note
Downloaded from manuals search enginewww.Manualslib.com


Produkt Specifikationer

Mærke: Optex
Kategori: Ikke kategoriseret
Model: AX-350DH MK3

Har du brug for hjælp?

Hvis du har brug for hjælp til Optex AX-350DH MK3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Optex Manualer

Optex

Optex RLS-PB2 Manual

26 Januar 2025
Optex

Optex QXI-DT-X5 Manual

14 December 2024
Optex

Optex WXI-R Manual

5 December 2024
Optex

Optex VXS-AM Manual

5 December 2024
Optex

Optex AX-100TFR Manual

5 December 2024
Optex

Optex FTN-AM Manual

5 December 2024
Optex

Optex SL-650QDP Manual

5 December 2024
Optex

Optex AP2-20N Manual

24 September 2024
Optex

Optex SIP-5030 Manual

19 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer