Læs gratis den danske manual til Optex AX-100TFR (12 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Optex AX-100TFR, eller vil du spørge andre brugere om produktet?

Side 1/12
-1-
Warning
Caution
Warning
Caution
N219
1
2
3
4
5
6
INSTALLATION INSTRUCTIONS
No.59-1552-1 090403
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
AX-100TFR/AX-200 TFR
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
AX-100TFR/AX-200 TFR
•AX-100TFR : Detection range: 30 m (100 ft.)
•AX-200TFR : Detection range: 60 m (200 ft.)
CONTENTS
Battery-operated detector
Batteries are not included.
Use four LSH20 (3.6 V, 13 Ah) batteries manufactured by SAFT.
Battery life: AX-100TFR Approximately five years
AX-200TFR Approximately three years (transmitter)
Approximately five years (receiver)
Back box for wireless transmitters
Back box can conceal two wireless transmitters and batteries.
N.C./N.O. selection switch
Both N.C. and N.O. input wireless transmitters can be used.
Battery saving function for wireless transmitter
Turning ON the battery saving timer switch reduces the battery
consumption of the wireless transmitter.
Intermittent output function
Turning ON the intermittent output function, alarm signals are sent
periodically to avoid missed alarms while the beam is broken.
4 channel beam frequency selector
Crosstalk is eliminated with 4, channel selectable, beam
frequencies. Used when stacking beams or for long range
applications.
International protection
IP55
LED indicator for an easy alignment
It flickers on/off to help with easy alignment located on the receiver.
D.Q. circuit (environmental disqualification)
The environmental compensation circuit is designed to eliminate
false alarms caused by snow, fog, heavy rain, ice and misalignment.
Tamper
Form C output activates when either cover or back box or chassis
is removed.
Beam interruption adjustment function
This function allows you to select the suitable beam interruption
time for any environment.
FEATURES
Failure to follow the instructions provided with
this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with
this indication and improper handling may cause
injury and/or property damage.
Do not use the product for purposes other than the detection
of moving objects such as people and vehicles.
Do not use the product to activate a shutter, etc., which may
cause an accident.
Do not touch the unit base or power terminals of the
product with a wet hand (do not touch when the product
is wet with rain, etc.). It may cause electric shock.
Never attempt to disassemble or repair the product. It may
cause fire or damage to the devices.
Do not use batteries other than those specified.
Specified batteries:
Four LSH20 batteries manufactured by SAFT
Do not use batteries that have different levels of power
remaining (i.e., new and used batteries).
Not observing the above may result in an explosion, leakage
of electrolyte, emission of toxic gases or other outcomes that
may be harmful to people and property.
[Handling of Batteries]
Fire, explosion and severe burn hazard. Do not recharge,
short circuit, crush, disassemble, heat above 100°C (212°F),
incinerate, or expose contents to water.
Do not solder directly to the cell.
Do not pour water over the product with a bucket, hose, etc.
The water may enter, which may cause damage to the
devices.
Clean and check the product periodically for safe use. If any
problem is found, do not attempt to use the product as it is
and have the product repaired by a professional engineer or
electrician.
Read this instruction manual carefully prior to installation.
After reading, store this manual carefully in an easily accessible
place for reference.
This manual uses the following warning indications for correct use
of the product, harm to you or other people and damage to your
assets, which are described below. Be sure to understand the
description before reading the rest of this manual.
This symbol indicates prohibition. The specific prohibited
action is provided in and/or around the figure.
This symbol requires an action or gives an instruction.
INTRODUCTION
1-1 BEFORE YOUR OPERATION 1
1-2 PRECAUTIONS 2
1-3 PARTS IDENTIFICATION 2
PREPARATIONS
2-1 ORDERING DETECTOR BATTERIES 2
2-2
CHECKING THE WIRELESS TRANSMITTER SIZE
2
INSTALLATION
3-1 WALL MOUNTING 3
3-2 POLE MOUNTING 4
3-3 MOUNTING IN THE BEAM TOWER 5
3-4 WIRING 7
SETTING
4-1 FUNCTION 8
4-2
4 CHANNEL BEAM FREQUENCY SELECTOR
8
4-3 OPTICAL ALIGNMENT 9
4-4 BEAM INTERRUPTION ADJUSTMENT 9
4-5 ADJUSTING OUTPUT 10
OPERATION CHECK
5-1 LED INDICATION 11
5-2 OPERATION CHECK 11
5-3 TROUBLE SHOOTING 11
SPECIFICATIONS
6-1 SPECIFICATIONS 12
6-2 DIMENSIONS & OPTION 12
INTRODUCTION
1
1-1 BEFORE YOUR OPERATION
-2-
1 m (3.3 ft.)
Receiver
Transmitter
(different
model)
Transmitter
2
1
2
1
3
AX-100TFR
Detection range: 30 m (100 ft.)
AX-200TFR
Detection range: 60 m (200 ft.)
Installation Height
0.7 m - 1 m
(2.3 ft. - 3.3 ft.)
Install the unit on a stable
surface.
Install the pole in a location
where sufficient stability can be
ensured.
Do not install the unit in a
location where trees, leaves, or
other objects that may swing in
the wind may block the beam.
Do not install the receiver in a
location where it is exposed to
direct sunlight.
Observe the prescribed
transmitter-receiver distance
(range) and installation height.
The pole size should be 43 -
48 mm ( 1.69" - 1.89").
Do not allow the infrared beam
from a different model to reach
the receiver.
Install the unit more than 1 m
(3.3 ft.) away from the wall or
fence that are running parallel
to the beam.
ChassisBack boxMain unitCover
Back box lock screw
Harness retainer plate
Cover lock screw
Accessories>>
Removing the Back Box >>
Removing the Cover >>
Velcro tape: 2 setsU-brackets: 2
Mounting plate
lock screws Pole mounting bracket set
Pole brackets: 6
M3×8 screws: 6
M4×20 screws: 4
M4×30 screws: 4
Loosen the
back box lock screw.
Pull
Press
Loosen the
cover lock screw.
Pull
Use two wireless transmitters for the each of receivers and
transmitters. When wireless transmitters with two or more inputs are
available, use one wireless transmitter for the each of transmitters
and receivers.
The following figure shows the dimensions of the wireless transmitter
installation space in the back box. Note that transmitters with
dimensions greater than those are not applicable.
Specified batteries: Four LSH20 batteries manufactured by SAFT
For information about batteries, visit the following website and
contact your local SAFT sales representative.
http://www.saftbatteries.com/Contacts/tabid/72/FP/9/FROM/PROD
UIT/Default.aspx
• Be sure to monitor the alarm and low battery outputs.
• To monitor the tamper output, include a wireless transmitter
supporting three or more inputs into the system.
Note>>
1-2 PRECAUTIONS
PREPARATIONS
2
2-1 ORDERING DETECTOR BATTERIES
2-2 CHECKING THE WIRELESS
TRANSMITTER SIZE
1-3 PARTS IDENTIFICATION
42.5 (1.67)
42.5 (1.67)
26.5 (1.04)
26.5
(1.04)
78 (3.07)
78 (3.07)
66 (2.60)
154 (6.06)
154 (6.06)
Unit: mm (inch)
The cross ( ) mark indicates prohibition.


Produkt Specifikationer

Mærke: Optex
Kategori: Ikke kategoriseret
Model: AX-100TFR

Har du brug for hjælp?

Hvis du har brug for hjælp til Optex AX-100TFR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Optex Manualer

Optex

Optex RLS-PB2 Manual

26 Januar 2025
Optex

Optex QXI-DT-X5 Manual

14 December 2024
Optex

Optex WXI-R Manual

5 December 2024
Optex

Optex VXS-AM Manual

5 December 2024
Optex

Optex AX-100TFR Manual

5 December 2024
Optex

Optex FTN-AM Manual

5 December 2024
Optex

Optex SL-650QDP Manual

5 December 2024
Optex

Optex AP2-20N Manual

24 September 2024
Optex

Optex SIP-5030 Manual

19 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer