Please check that the article is complete as
specied in the scope of delivery. If parts are
missing, please contact our service center or the
sales outlet where you made your purchase at
the latest within 5 working days after purchasing
the product and upon presentation of a valid bill
of purchase. Also, refer to the warranty table in
the service information at the end of the operating
Open the packaging and take out the
Remove the packaging material and any
packaging and/or transportation braces (if
Check to see if all items are supplied.
Inspect the equipment and accessories for
If possible, please keep the packaging until
the end of the guarantee period.
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suocating!
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or
injuries of any kind caused as a result of this.
The equipment is to be used only for its
prescribed purpose. Any other use is deemed to
be a case of misuse. The user / operator and not
the manufacturer will be liable for any damage or
injuries of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
Important information about the power
This equipment falls under Class A of the stan-
dard EN 60974-10, i.e. it is not designed for use
in residential areas in which the power supply
is based on a public low-voltage supply system
because given unfavorable conditions in the pow-
er supply the equipment may cause interference.
If you want to use the equipment in residential
areas in the which the power supply is based on
a public low-voltage supply system, you must use
an electromagnetic lter which reduces the elec-
tromagnetic interference to the point where the
user no longer notices any disturbance.
In industrial parks or other areas in which the
power supply is not based on a public low-voltage
supply system the equipment can be used wi-
Symbols and technical data
Input voltage: ............................... 230 V ~ 50 Hz
Max. no load voltage: ....................................48V
Current range: ....................................... 55-130A
Peak current: ...............................................140A
Duty cycle: ..................................... 10% 130amp
Electrode size: ............................. ∅ 2.0-3.2 mm
EN 60974-6 European standard for arc
power supplies with limited on
~ 50 Hz Alternating current and
rated frequency value [Hz]
130 A/ 23.2 V Maximum welding current and
Ø Electrode diameter [mm]
Line input; number of phases,
the alternating current symbol
and the rated frequency value
Highest rated value of the line
Eective value of the highest
= 48 V 55 A / 20.2 V - 130 A / 23.2 V
1. While working, the welder must protect his en-
tire body from radiation and burns by wearing
suitable clothing and a face guard.
2. Slip-on gloves made of a suitable material
(leather) must be worn on both hands. They
must be in perfect condition.
3. Suitable aprons must be worn to protect clo-
thing from sparks and burns. A safety suit and,
if necessary, head protection must be worn if
required by the type of work in question, e.g.
4. The protective clothing used as well as all
accessories must be in compliance with the
“Personal safety equipment” EU Directive.
Protection from radiation and burns
1. Provide information about the risk to eyes at
the working site in the form of a poster with
the wording “Caution – do not look at the a-
mes”. Workplaces are to be screened o
wherever possible so that personnel in the
vicinity are protected. Unauthorized persons
are to be kept away from the welding work.
2. The walls in the immediate vicinity of statio-
nary workplaces should not have a light color
or a sheen. Windows up to head height are
to be protected against radiation passing th-
rough them or reecting o them, for example
by coating them with a suitable paint.
Never place any electric power tools in your
To comply with European Directive 2012/19/EC
concerning old electric and electronic equipment
and its implementation in national laws, old
electric power tools have to be separated from
other waste and disposed of in an environment-
friendly fashion, e.g. by taking to a recycling
Recycling alternative to the return request:
As an alternative to returning the equipment to
the manufacturer, the owner of the electrical
equipment must make sure that the equipment
is properly disposed of if he no longer wants to
keep the equipment. The old equipment can be
returned to a suitable collection point that will
dispose of the equipment in accordance with the
national recycling and waste disposal regulations.
This does not apply to any accessories or aids
without electrical components supplied with the
The product meets the requirements of EN
60974-10 and is subject to special connection
conditions. This means that use of the product
at any freely selectable connection point is
Given unfavorable conditions in the power
supply the product can cause the voltage to
The product is intended solely for use at
a) do not exceed a maximum permitted sup-
ply impedance Zsys = 0.25 + j 0.25, or
b) have a continuous current-carrying capaci-
ty of the mains of at least 100 A per phase.
As the user, you are required to ensure, in
consultation with your electric power compa-
ny if necessary, that the connection point at
which you wish to operate the product meets
one of the two requirements, a) or b), named
Highest welding time rated value in continuous
(max) for highest welding current rated
value at an ambient temperature of 20 °C, expres-
sed in minutes and seconds.
Highest welding time rated value in intermittent
for highest welding current rated value
at an ambient temperature of 20 °C over an un-
interrupted time of 60 min, expressed in minutes
Beiblatt_AWG_964U.indd 2 25.08.2016 15:13:36