BB 44X / OPTION 88 OPERATORS MANUAL
Application Information
Driving Impedances
Some people wrongly feel you cannot use a transformer to con-
vert between -10 dBV and +4 dBu because of low impedances.
is is not a problem as long as you use them to interconnect
equipment with at least 15 kΩ input impedance. Since most
professional products have input impedances of 20 kΩ or greater
(50k and 100 kΩ are not uncommon), this should never be di-
with the -10 dBV output (due to transformer action). is may
seem excessively low, but is not in practice. e maximum trans-
former output level of +24 dBu occurs with an input level of +10
dBV, which equals 3.16 volts. And 3.16 volts driving 1 kΩ only
requires 3.16 milliamps, which is a very modest requirement for
any -10 dBV equipment to deliver.
Wiring
e BB 44X follows AES/ANSI/IEC standards of pin 2 positive
and pin 3 negative. Note the shields (commons) of the RCA
jacks are tied for the Inputs and the Outputs but not to each oth-
er. is allows ground isolation of stereo Input and Output pairs.
A positive signal applied to pin 2 of the 3-pin connectors causes
a positive signal to appear on the tip of the associated RCA jacks,
and vice-versa.
Signal Direction
Signal can be converted through the channels either direction.
at means there is the possibility of having 4 channels -10 dBV
unbalanced to +4 dBu balanced, or vice versa (in the standard
unit). e only problem arises in the gender of the XLR con-
nector. e solution requires same-sex XLR adaptors or special
cables.
Chassis Grounding
A tapped hole and a #6-32 screw is provided for chassis ground-
ing purposes. Good practice dictates earth-grounding the BB
44X. If the grounding integrity of the rack screws is in doubt,
run a wire from this screw to a known earth ground.
Expansion Assembly
e OPT 88 (Option 88) expands the BB 44X into an eight
channel model. e OPT 88 consists of a printed circuit board
with four additional transformers and jacks soldered in place.
e OPT 88 installs easily in the blank side of the BB 44X.
Assembly is simple: remove the cover, install the board in place,
and secure with the supplied mounting screws. No soldering
required; all you need are #1 and #2 Phillips screwdrivers. See
the illustration on the next page.
e OPT 88 may be used in some environments without the
BB 44X, however best RFI rejection is obtained using the cold
rolled steel metal chassis of the BB 44X.
INPUT 1
T4
OUTPUT 1
9
11 4
2
3
2
1
+4 dBu -10 dBV
11 4
2
INPUT 2
+4 dBu
9 2
T3
-10 dBV
OUTPUT 2
3
114
2
1
OUTPUT 3
+4 dBu
92
T2
-10 dBV
INPUT 3
3
114
2
1
OUTPUT 4
+4 dBu
92
T1
-10 dBV
INPUT 4
3
1
All features & specications subject to change without notice 12275
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 TEL 425-355-6000 FAX 425-347-7757 WEB rane.com
BALANCED
UNBALANCED
2 4
BALANCED
1 3
BALANCED
UNBALANCED
6 8
BALANCED
5 7
M2.9 X 5/16" SCREW (9 PLACES)
6-32 X 3/16" SCREW (2 PLACES)
INSTALLATION INSTRUCTIONS:
1. REMOVE THE (7) TOP COVER SCREWS.
2. REMOVE TOP COVER.
3. INSTALL PCB ASSEMBLY INTO CHASSIS.
4. INSTALL THE (11) REAR PANEL SCREWS.
5. INSTALL THE (2) BOTTOM SCREWS.
6. REPLACE TOP COVER.
7. REPLACE THE (7) TOP COVER SCREWS.
8. PLUG AND PLAY.
PCB ASSEMBLY
H:\BB44\105185.DWG
4-40 X 1/4" SCREW (2 PLACES)
(9) M2.9 X 5/16" AND (2) 4-40 X 1/4"
BB 44X
4321
87
65
RANE CORP.
ACN001.187.837
PIN 2
BALANCED WIRING:
PIN 1
PIN 3
CHASSIS GROUND
NEGATIVE
POSITIVE
INPUTS
+4dBu
OUT
-10dBV
IN
-10dBV
OUTPUTS
+4dBu
INPUTS
+4dBu
OUT
-10dBV
IN
-10dBV
OUTPUTS
+4dBu
WARNING: is product may contain chemicals
known to the State of California to cause cancer,
or birth defects or other reproductive harm.
Parameter LimitSpecication Units Conditions/Comments
Transformer Construction Nickel Core Bobbin Wound Grade “80” Ni
Turns Ratio -10 dBV (316 mV): +4 dBu (1.23 V)1:3.89
Maximum Levels (In or Out )
..........-10 dBV +10 (40 Hz-20 kHz); +4.5 (20 Hz) 1% THD point0.5dB dBV
..........+4 dBu +24 (40 Hz-20 kHz); +18.5 (20 Hz) 1% THD point0.5dB dBu
Input Impedance (Load impedances as shown)
..........-10 dBV 1k 5 % Ω Load impedance 15 kΩ
..........+4 dBu 15k 5 % Ω Load impedance 1 kΩ
Insertion Loss 0.5 0.1 dB With recommended load impedance
DC Resistance 47.5 / 200 Ω -10 dBV / +4 dBu10%
Frequency Response 20 Hz -20 kHz +4 dBu In or Out; rec. load impedance±2 dB
THD + Noise less than .05 (40 Hz-20 kHz) % +4 dBu In or Outmax
Unit: Conformity CE, FCC Exempt
..........Size 1.75"H x 19"W x 5.3"D (1U) (4.4 cm x 48.3 cm x 13.3 cm)
..........Weight 4 lb (3 kg)
Shipping: Size 4.25" x 20.3" x 13.75" (11 cm x 52 cm x 35 cm)
..........Weight (5 kg)8 lb
All specications apply both directions, unless noted. 0 dBu = 0.775 volts; 0 dBV=1.0 volts


Produkt Specifikationer

Mærke: Rane
Kategori: Ikke kategoriseret
Model: BB 44X

Har du brug for hjælp?

Hvis du har brug for hjælp til Rane BB 44X stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Rane Manualer

Rane

Rane SM26S Manual

20 Juni 2025
Rane

Rane AC 22 Manual

20 Juni 2025
Rane

Rane AC 23 Manual

20 Juni 2025
Rane

Rane FT 45 Manual

20 Juni 2025
Rane

Rane FME 15 Manual

20 Juni 2025
Rane

Rane ECS Ware Manual

20 Juni 2025
Rane

Rane FAC 28 Manual

20 Juni 2025
Rane

Rane SM 82S Manual

20 Juni 2025
Rane

Rane RPM 26 Manual

20 Juni 2025
Rane

Rane SSE 35 Manual

20 Juni 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer