Tripp Lite NSU-G16 Manual


Læs gratis den danske manual til Tripp Lite NSU-G16 (14 sider) i kategorien stikdase. Denne vejledning er vurderet som hjælpsom af 21 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 11 anmeldelser. Har du et spørgsmål om Tripp Lite NSU-G16, eller vil du spørge andre brugere om produktet?

Side 1/14
1
Owner’s Manual
Rackmount
Network Switch
with Built-in PDU
Model: NSU-G16
(Series Number: AG-00C6)
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
14-09-040-9332E0.indd 1 9/8/2014 2:35:07 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be
followed during the installation, operation and storage of this Tripp Lite product.
Failure to heed these warnings may affect your warranty.
PDU/Switch Location Warnings
The switch provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
The switch is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
For best performance, maintain an indoor temperature between 32º F and 104º F (0º C and
40º C) with relative humidity between 10% and 90% (non-condensing).
Leave adequate space around all sides of the switch for proper ventilation.
Keep the switch away from high-frequency, strong-current devices (e.g., radio transmitting
stations, transmitters and broadband amplifiers).
Use electromagnetic shielding (if required).
For rackmount configuration, ensure that both the rack and switch are properly grounded.
If the switch is not rack mounted, securely place it on a sturdy, flat surface.
Improper installation can cause product damage that is not covered by the warranty.
Do not expose the network switch’s connected networking cables to outdoor elements.
Do not use this product near water (e.g., in a wet basement, or near a swimming pool).
PDU/Switch Connection Warnings
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to signicantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
Keep the switch’s input power off during installation.
Use only the power cord that came included with the switch.
Make sure the power supply voltage matches the specifications indicated on the switch.
The total power requirement for equipment connected to the switch must not exceed the
maximum load rating for the PDU’s circuit breaker.
Do not connect the switch to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
Do not drill into or attempt to open any part of the switch housing. There are no user-
serviceable parts inside.
Do not attempt to modify the switch, including the input plugs and power cables.
Do not attempt to use the switch if any part of it becomes damaged.
Make sure network cables are properly seated. A clicking sound will be made when a cable is
installed correctly.
If the power cord is damaged, do not attempt to connect the switch. Contact a Tripp Lite
Service Representative for assistance.
Never attempt to install or use the switch during a thunderstorm.
14-09-040-9332E0.indd 2 9/8/2014 2:35:07 PM


Produkt Specifikationer

Mærke: Tripp Lite
Kategori: stikdase
Model: NSU-G16
Vekselstrømsindgangsspænding: 120 V
Bredde: 474 mm
Dybde: 213.4 mm
Højde: 43.4 mm
Vægt: 2720 g
Produktfarve: Sort
Pakkevægt: 3360 g
Pakkedybde: 533.4 mm
Pakkebredde: 315 mm
Pakkehøjde: 111.8 mm
Formfaktor: 1U
Opbevaringstemperatur (T-T): -10 - 70 °C
Relativ luftfugtighed ved drift (H-H): 5 - 95 %
Driftstemperatur (T-T): 0 - 40 °C
Kabler inkluderet: Vekselstrøm
Certificering: UL 60950-1, CAN/CSA-C22.2, FCC , RoHS , REACH
Netværksstandarder: IEEE 802.3,IEEE 802.3ab,IEEE 802.3i,IEEE 802.3u,IEEE 802.3x
LED-indikatorer: LAN,Power
Kan monteres på væggen: Ja
Harmoniseret systemkode (HS): 8517.62.0020
Driftshøjde: 0 - 3000 m
Hovedkassen højde (udvendigt): 475 mm
Hovedkassens længde (udvendigt): 553.7 mm
Hovedkassens bruttovægt (udvendigt): 14380 g
Hovedkassens bredde (udvendigt): 330.2 mm
Oprindelsesland: Kina
Indgangsstrøm: 12 A
Produkter pr. hovedkasse (udvendigt): 4 stk
Fuld duplex: Ja
Hovedkasse (udvendig) GTIN (EAN/UPC): 10037332184013
Switch-type: Ikke administreret
10G understøttelse: Ingen
Basis omskiftning RJ-45 Ethernet porte, antal: 16
Basis omskiftning RJ-45 Ethernet porttype: Gigabit Ethernet (10/100/1000)
Opbevar-og-frem: Ja
MAC adresselabel: 8000 entries
Switch kapacitet: 32 Gbit/sek.
Jumbo Frames support: Ja
Jumbo rammer: 9216
Stativ-montering: Ja
Minimum RAM: 2 MB

Har du brug for hjælp?

Hvis du har brug for hjælp til Tripp Lite NSU-G16 stil et spørgsmål nedenfor, og andre brugere vil svare dig