Tripp Lite PDU3EVN6L2130B Manual

Tripp Lite stikdase PDU3EVN6L2130B

Læs nedenfor 📖 manual på dansk for Tripp Lite PDU3EVN6L2130B (64 sider) i kategorien stikdase. Denne guide var nyttig for 16 personer og blev bedømt med 5.0 stjerner i gennemsnit af 8.5 brugere

Side 1/64
1
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
3-Phase Monitored & Switched
0U Power Distribution Units
(Phase, Bank, Outlet Measurements*)
208V MONITORED
MODELS SERIES NO.
PDU3EVN3L2130 AG-00B9
PDU3EVN10L2130 AG-00B9
PDU3EVN3L2120 AG-00B8
PDU3EVN6L2120 AG-00B8
PDU3EVN10L2120 AG-00B8
PDU3EVN6L2130 AG-00B9
208V SWITCHED
MODELS SERIES NO.
PDU3EVSR6G60A AG-0094
PDU3EVSR6H50A AG-0094
200 – 240V
MONITORED
MODELS SERIES NO.
PDU3EVN6G30B AG-00BA
PDU3EVN10G30B AG-00BA
PDU3EVN3G60B AG-00BA
PDU3EVN6G60B AG-00BA
PDU3EVN10G60B AG-00BA
PDU3EVN3H50B AG-00BA
PDU3EVN6H50B AG-00BA
PDU3EVN10H50B AG-00BA
PDU3EVN3L1530B AG-00BA
PDU3EVN6L1530B AG-00BA
PDU3EVN10L1530B AG-00BA
PDU3EVN3L2130B AG-00BA
PDU3EVN6L2130B AG-00BA
PDU3EVN10L2130B AG-00BA
PDU3EVN6G60C AG-00BB
200 – 240V
SWITCHED
MODELS SERIES NO.
PDU3EVSR6H50 AG-00BA
PDU3EVSR10H50 AG-00BA
PDU3EVSR6L1530 AG-00BA
PDU3EVSR10L1530 AG-00BA
PDU3EVSR6L2130 AG-00BA
PDU3EVSR10L2130 AG-00BA
PDU3EVS6H50 AG-00BA
PDU3EVS6L2130 AG-00BA
PDU3EVS6L2120 AG-00BC
PDU3EVSR6L2120 AG-00BC
PDU3EVSR6L1520 AG-00BC
380 – 415V
MONITORED
MODELS SERIES NO.
PDU3XEVN6G20 AG-00BD
380 – 415V
SWITCHED
MODELS SERIES NO.
PDU3XEVSR6G20 AG-00BD
PDU3XEVSR6G30A AG-0096
PDU3XEVSR6G30B AG-0096
PDU3XEVSR6G32A AG-0096
PDU3XEVSR6G32B AG-0080
PDU3XEVSR6G60A AG-0096
PDU3XEVSR6G60B AG-0093
PDU3XEVSR6G63A AG-0096
PDU3XEVSR6G63B AG-0094
PDU3XEVSR6L230B AG-0056
PDU3XEVSR6L2230 AG-0096
PDU3XEVSRHWA AG-0096
PDU3XEVSRHWB AG-0057
Español 17 • Français 33 49Русский
17-06-566-93349E.indb 1 9/18/2017 4:23:16 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation, and storage of this product. Failure to heed these
instructions and warnings may affect the product warranty.
The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
The PDU must be installed by a qualified technician only.
Do not attempt to mount the PDU to an insecure or unstable surface.
Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
Connect the PDU to an outlet that is in accordance with your local building codes and that is
adequately protected against excess currents, short circuits and earth faults.
The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
Never attempt to install electrical equipment during a thunderstorm.
Individual equipment connected to the PDU should not draw more current than the individual
PDU’s outlet’s rating.
The total load connected to the PDU must not exceed the maximum load rating for the PDU.
Do not attempt to modify the PDU, input plugs or power cables.
Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
Do not attempt to use the PDU if any part of it becomes damaged.
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to signicantly
affect its safety or effectiveness is not recommended.
17-06-566-93349E.indb 2 9/18/2017 4:23:16 PM


Produkt Specifikationer

Mærke: Tripp Lite
Kategori: stikdase
Model: PDU3EVN6L2130B
Type: Trefaset
Vekselstrømsindgangsfrekvens: 50 - 60 Hz
Bredde: 55.1 mm
Dybde: 63.2 mm
Højde: 1778 mm
Vægt: 7120 g
Brugervejledning: Ja
Produktfarve: Black,Grey
Pakkevægt: 10320 g
Pakkedybde: 1927.1 mm
Pakkebredde: 245.1 mm
Pakkehøjde: 175 mm
Opbevaringstemperatur (T-T): -15 - 60 °C
Relativ luftfugtighed ved drift (H-H): 5 - 95 %
Driftstemperatur (T-T): 0 - 50 °C
Skærm: LCD
Husmateriale: Metal
Dimensioner (BxDxH): 55 x 73 x 1778 mm
Understøttede netværksprotokoller: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP
Kabellængde: 1.8 m
Bæredygtighedscertifikater: RoHS
Driftshøjde: 0 - 3000 m
Oprindelsesland: Taiwan
Produkter pr. hovedkasse (udvendigt): 1 stk
Maksimal ydeevne: 10000 W
Montering: Lodret
Strømstik: NEMA L21-30P
Nominel udgangsspænding: 200-240 V
Nominel indgangsspænding: 200-240 V
AC udgange, antal: 48 AC stikkontakt(er)
AC stikkontakt typer: C13 coupler,C19 coupler
Rackkapacitet: 0U
Strøm (maks.): 24 A
PDU-typer: Overvåget

Har du brug for hjælp?

Hvis du har brug for hjælp til Tripp Lite PDU3EVN6L2130B stil et spørgsmål nedenfor, og andre brugere vil svare dig