Thank you for purchasing this Whale® product. For over 60 years, Whale® has led the way in the design and manufacture of freshwater and waste systems including:
pumps, plumbing faucets, showers for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by
excellent customer service. Read carefully before installation and use. For information on our full product range visit: www.whalepumps.com
Designed for use in low voltage applications including leisure boats or recreational vehicles such as caravans or motorhomes to pump cold clean freshwater. If it is
intended for use with any other liquid, it is the user’s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe
working practice is applied to installation, use and maintenance.
CONTENTS
1. Speci cation
2. Principles of Operation
3. Application
4. Warnings
5. Installation
6. Operation
7. Maintenance
8. Helpful Hints
9. Service Support Details
10. EU Declaration of Conformity, Standards and Approvals
11. Warranty Statement
1
Self-Venting Submersible
& In-Line Booster Pumps
INSTALLATION & USER INSTRUCTIONS
TYPICAL INSTALLATION
LIST OF IMAGES
Fig A. Submersible Pump Installation
Fig B. In-line Pump Installation
1. SPECIFICATION
Model Standard Premium Premium High Flow
Product Code UK Speci cation GP1002 GP1352 GP1354 GP1652
Product Code EU Speci cation GP1010 GP1356 GP1358 GP1656
Voltage 12V d.c. 12V d.c. 24V d.c. 24V d.c.
Recommended Fuse Size 5 amp automotive 3 amp automotive 5 amp automotive
Weight 0.15 kg (0.3 lbs)
Hose Connections
Suitable for 10 mm (38”) or 13 mm ( ”) Flexible Hose½
For ½” hose connection:
Fit adaptor by pressing on rmly. Note: Once tted adaptors cannot be removed.
For 15mm Quick Connect Plumbing:
Use WX1511B (Stem Adaptor 11 mm-15 mm). Connect WX1504 (15 mm Equal Straight) and then 15 mm Plumbing
For 12mm Quick Connect Plumbing:
Use Whale part: WU1211B, and connect WU1204 and then 12mm plumbing
Material In Contact with Liquid Pump Body: ABS, Seals: Nitrile®, Strainer: Polypropylene, Impeller: PBT, Cable: PVC
Discharge Head
Flow Rate Per Minute
Current Draw
(Note: performance may vary depending on speci c installations)
0 m (0 ft) 10.3 ltrs 13.2 ltrs 13.2 ltrs 15.75 ltrs
2.4 amps 3.6 amps 3.8 amps 3.8 amps
1 m (3 ft) 8.75 ltrs 11.75 ltrs 11.75 ltrs 14.75 ltrs
2.2 amps 3.3 amps 1.6 amps 3.7 amps
3 m (9 ft) 5.75 ltrs 9.75 ltrs 9.75 ltrs 12.75 ltrs
2.0 amps 2.9 amps 1.455 amps 3.5 amps
Submersible - Model Speci cations
In Line - Model Speci cations
Model In-Line Premium In-Line Premium In-Line High Flow
Product Code GP1392 GP1394 GP1692
Voltage 12V d.c. 24V d.c. 12V d.c.
Recommended Fuse Size 5 amp automotive 3 amp automotive 5 amp automotive
Weight 0.15 kg (0.3 lbs)
Hose Connections
Suitable for 10 mm (38”) or 13 mm ( ”) Flexible Hose½
For ½” hose connection:
Fit adaptor by pressing on rmly. Note: Once tted adaptors cannot be removed.
For 15mm Quick Connect Plumbing:
Use WX1511B (Stem Adaptor 11 mm-15 mm). Connect WX1504 (15 mm Equal Straight) and then 15 mm Plumbing
For 12mm Quick Connect Plumbing:
Use Whale part: WU1211
Material In Contact with Liquid Pump Body: ABS, Seals: Nitrile®, Strainer: Polypropylene, Impeller: PBT, Cable: PVC
EN
2
Discharge Head Flow Rate Per Minute
Current Draw
0 m (0 ft) 13.2 ltrs 13.2 ltrs 15.75 ltrs
3.6 amps 3.8 amps 3.8 amps
1m (3 ft) 11.75 ltrs 11.75 ltrs 14.75 ltrs
3.3 amps 1.6 amps 3.7 amps
3m (9 ft) 9.75 ltrs 9.75 ltrs 12.75 ltrs
2.9 amps 1.45 amps 3.5 amps
Note: Pump performance will depend on the plumbing system and restrictions on outlets in your installation. Premium and High Flow models come with
38” (10mm) hose
connection. They can be adapted for ½” (13mm) hose by pushing on the ½” adaptors supplied with the pump. Whale’s policy is one of continuous improvement and we
reserve the right to change speci cations without prior notice.
To the tter
Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read the points listed below. Also
ensure that these operating instructions are passed on to the end user.
To the user
Read the points listed below before installation and use of equipment.
• These pumps are designed to pump clean cold freshwater in low voltage applications such as a leisure boat or recreational vehicle.
• Submersible models designed to be run fully submerged in water, another In-Line Booster pump is designed to be run in the pipe line between the water supply and the
outlet.
• The pumps are rated for intermittent use only- maximum continuous operation should not exceed 15 minutes.
• Ensure that a system of safe working practice is applied to installation, use and maintenance.
Always disconnect power sources before installing or making connections.
• Wiring must comply with applicable electrical standards and include a 5 Amp automotive fuse for each pump. Improper wiring can cause a re resulting in injury or
death. Suggested wiring information is given as a guide only.
• Please note that incorrect installation may invalidate the warranty.
• Not suitable for petrol, low ash point liquids and aggressive chemicals. This pump be used for pumping petrol or any highly inmust not ammable or corrosive liquids.
• Do not use the pump in water temperatures above 40ºC (100ºF).
• For submersible pump models it is best to stand the pump vertically in the tank.
• Contact Whale® Support on 028 9127 0531 for additional advice on this product or installation.
1. - The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised modiPlease note cation or misuse of this product.
2. Before installing, ensure that the system is fully drained before starting the installation. To do this open and close all outlets to expel water and air and check
that the submersible pump can reach the bottom of the water container.
For plumbing connections see Speci cation table above. The pump outlet be higher than the inlet.MUST
Must be installed in one of the following ways:-
Note: Where there is a long run of pipe between the pump and the faucet, it is helpful to insert a check valve (FV1227) in the pipe close to the faucet.
Step 1
Switch off the 12V d.c. supply
Step 2
Connect to an appropriate 12 or 24 Volt power supply and switch.
Step 3
• Fit the required length of hose to the pump and then fully immerse the pump in the water container.
• To avoid entry of air or water leaks it is important that all hose connections (to pump, tank, water heater and taps / faucets) are securely fastened.
• If using with a Whale In-Line Pressure Switch, (WU7207) an isolator switch installed to protect the pump from accidental switch on when the system is not in must be
use. The pressure switch must be tted into the pipework in close proximity to the pump and before any other ttings (see Fig. A).
• For plumbing connections see Speci cation table above
• Must be installed in one of the following ways:-
1. With a foot operated pump (Fig. B1 and Fig. B2). Position the Pump in the suction pipe between the foot pump and the water tank, not between the foot pump and
faucet.
2. In-line to boost a submersible pump (Fig. B3).
3. With a hand operated pump (Fig. B4).
4. In a pressurized system (Fig. B5).
• Where there is a long run of pipe between the pump and the faucet, it is helpful to insert a check valve (FV1227) in the pipe close to the faucet.
Priming the pump.
• When fully immersed in water Submersible pumps are primed and give instant water delivery.
• In-Line Booster pumps primed using either by gravity (as in Fig. B5) or operating a hand pump (Fig. B4) or foot pump (Fig. B1 and Fig. B2) until full water must be ow
from the outlet.
o Once primed the pump is ready for use and should remain primed for repeated use.
o As an additional safeguard, a Whale check valve (FV1227) can be inserted in the suction pipe. (Fig. A2 / Fig. B3) re-priming should only be
necessary when the water supply has been completely drained and the tank is re lled.
o If using a Whale Tiptoe pump, leave the plunger in the “locked down” position whilst operating. Ensure the isolation switch is on. Open the
tap / pump should start.
2. PRINCIPLES OF OPERATION
3. APPLICATION
SUBMERSIBLE PUMP INSTALLATION - See Fig. A
5. INSTALLATION - ALL MODELS
4. WARNINGS
1. With a oor pump - Fig. A1
2. With a microswitchwed tap/faucet - Fig. A2 and Fig. A3
3. With a pressure switch system - Fig. A4
• Brown wire to positive
• Blue wire to negative
• Each pump protected with the appropriate fuse
IN-LINE INSTALLATION - See Fig. B
6. OPERATION


Produkt Specifikationer