Læs gratis den danske manual til Wolf 808331 (8 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Wolf 808331, eller vil du spørge andre brugere om produktet?

Side 1/8
Page 1
IN-LINE BLOWER
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer or your dis-
tributor.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only steel ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe’).
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-
lent steam explosion will result.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
!
FOR DOMESTIC COOKING ONLY
!
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
y
“TYPICAL INSTALLATION”
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
y
“MOUNTING OPTIONS”
y
“WIRING PLATE POSITION”
y
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
y
“USE AND CARE”
For use with models CTWH30, CTWH36, IH4227, W302418-W422418, W302718-
W422418, W362210-W482210
MODEL 808331


Produkt Specifikationer

Mærke: Wolf
Kategori: Ikke kategoriseret
Model: 808331

Har du brug for hjælp?

Hvis du har brug for hjælp til Wolf 808331 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Wolf Manualer

Wolf

Wolf 808331 Manual

2 November 2025
Wolf

Wolf CWL-180 Manual

27 August 2024
Wolf

Wolf CWL-2-325 Manual

27 August 2024
Wolf

Wolf SM15TF/S Manual

29 Juli 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Hendi

Hendi 580035 Manual

3 November 2025
MSW

MSW -PTM-02 Manual

3 November 2025
ANCEL

ANCEL FX1000 Manual

3 November 2025
Extron

Extron RCP 401 Manual

3 November 2025
IFM

IFM E11847 Manual

3 November 2025
ANCEL

ANCEL S2000 Manual

3 November 2025
ANCEL

ANCEL HD3600 Manual

3 November 2025
Hendi

Hendi 550113 Manual

3 November 2025