READ AND SAVE
THESE INSTRUCTIONS
MODELS 120, 124 & 128
REGISTER HEATERS
MODELOS 120, 124 Y 128
CALENTADORES DE REJILLA
LEA Y CONSERVE
ESTAS INSTRUCCIONES
WARNING
1. ALL ELECTRICAL WORK MUST BE DONE IN
ACCORDANCE WITH LOCAL OR NATIONAL
ELECTRICAL CODE AS APPLICABLE. FOR
SAFETY, THIS PRODUCT MUST BE
GROUNDED. IF YOU ARE UNFAMILIAR WITH
METHODS OF INSTALLING ELECTRICAL WIR-
ING, SECURE THE SERVICES OF A QUALIFIED
ELECTRICIAN.
2. WHEN WIRING, SERVICING OR CLEANING
THIS UNIT, TURN OFF POWER AND LOCK OUT
SERVICE PANEL. FAILURE TO DO SO COULD
ALLOW OTHERS OR THERMOSTAT TO TURN
ON POWER UNEXPECTEDLY WHICH MAY
CAUSE FATAL ELECTRICAL SHOCK.
3. To avoid electrical shock:
DO NOT install unit in a tub or shower enclo-
sure or any location where it may come in con-
tact with water.
NEVER place a switch where it can be reached
from a tub or shower.
4. DO NOT install this unit in an area where chemi-
cals or other flammables are stored or used. Ex-
plosion and fire may result.
CAUTION
1. This product may ONLY be installed horizontally
in a wall. DO NOT MOUNT IN ANY OTHER PO-
SITION.
2. Install heater at least 6" from floor or any adja-
cent vertical surface.
3. DO NOT locate heater behind a door, furniture,
drapes, etc., where the air flow to the unit would
be restricted.
4. Provide heater with an appropriately-rated elec-
trical circuit to prevent tripped breakers or blown
fuses (See chart below.)
5. DO NOT CONNECT HEATER TO DIMMER
SWITCH OR SPEED CONTROL.
6. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc., off power unit.
7. Please read specification label on product for fur-
ther information and requirements.
PLAN THE
INSTALLATION
This heater is intended to be used to supply supple-
mental heat from a wall location in new or existing
construction.
The heater can be operated using the Broan Model
86 Line-Voltage Thermostat from a wall location. Pur-
chase the control separately.
Plan to supply the heater with proper line voltage and
appropriate power cable.
NOTE: Power can be tapped from a nearby circuit
depending on the heater wattage required and the
amperage rating of the circuit.
Heater can be converted to half-wattage to avoid over-
loading such circuits.
The table below lists the ratings for each model.
FIG. 1
INSTALLER: Leave This Manual With The Homeowner. HOMEOWNER: Use and Care Information on Page 3.
INSTALADOR: Deje este manual con el duo de casa. DUEÑO DE CASA: Informacn del uso y mantenimiento en la página 3.
MODELS
120
124
128
VOLTS
120
240
208
120
240
208
240
208
AMPS
8.33/4.16
4.16
3.61
12.5/6.25
6.25
5.41
6.33/4.16
7.21/3.61
WATTS
1000/500
1000
750
1500/750
1500
1125
2000/1000
1500/750
BTU/HR
3413/1707
3413
2560
5120/2560
5120
3840
6827/3413
5120/2560
DRYWALL/
PARED DE
YESO
GRILLE/
REJILLA
WALL
STUD/
VIGA DE
LA PARED
HEATER
HOUSING/
CAJA DEL
CALENTADOR
POWER
CABLE/
CABLE
DE
ENERGIA
ADVERTENCIA
1. TODO EL TRABAJO ELECTRICO DEBE REALIZARSE
DE ACUERDO CON LOS CODIGOS ELECTRICOS
LOCALES Y/O NACIONALES CORRESPONDIENTES.
PARA SU SEGURIDAD, ESTE PRODUCTO DEBE
SER CONECTADO A TIERRA. SI USTED NO ESTA
FAMILIARIZADO CON LOS METODOS DE
INSTALACION DEL CABLEADO ELECTRICO,
OBTENGA LOS SERVICIOS DE UN ELECTRICISTA
COMPETENTE.
2. AL HACER EL CABLEADO, LIMPIEZA O DAR
SERVICIO A ESTA UNIDAD, DESCONECTE LA
POTENCIA Y ASEGURE EL PANEL DE SERVICIO. EL
NO HACERLO PUEDE HACER POSIBLE QUE OTRAS
PERSONAS O EL TERMOSTATO ACTIVE LA ENERGIA
EN FORMA INESPERADA, LO QUE PUEDE CAUSAR
UN GOPE ELECTRICO MORTAL.
3. Para evitar descarga eléctrica:
*NO instale la unidad en una bañera o recinto de ducha,
ni en ningún lugar donde pueda entrar en contacto
con el agua.
*NUNCA coloque un interruptor en un lugar que pueda
ser alcanzado desde una bañera o ducha.
4. NO instale esta unidad en un área donde se almacenen
o usen productos químicos u otros productos inflamables.
De lo contrario, pueden producirse explosiones e
incendios.
CUIDADO
1. Este producto SOLAMENTE se puede instalar
horizontalmente verticalmente en una pared. NO LO
MONTE EN NINGUNA OTRA POSICION.
Translators note for items underlined above: although
the manual in English reads horizontally and I trans-
lated the word literally, I suspect it should be “verti-
cally(in Spanish: verticalmente). Whichever the case
turns out to be, remove the underline and delete the
word that does not apply.
2. Instale el calentador por lo menos a 15,24 cm (6 pulg.)
de distancia del piso o de alguna superficie vertical
adyacente.
3. NO COLOQUE el calentador dets de una puerta,
muebles, cortinas, etc., donde el flujo de aire a la unidad
se encuentre restringido.
4. Proporcione un circuito eléctrico de capacidad nominal
al calentador, a fin de impedir la desconexión de
disyuntores o quemado de fusibles. (Véase el diagrama
abajo).
5. NO CONECTE EL CALENTADOR A UN VARIADOR DE
LUZ O UN CONTROL DE VELOCIDAD.
6. Para evitar daños al cojinete del motor e impulsores ruidosos
y/o desequilibrados, mantenga la unidad de enera alejada
de roos de yeso, polvo de construccn, etc.
7. Para más información y requisitos, lea la etiqueta de
especificación sobre el producto.
PLANIFICACION DE LA
INSTALACION
Este calentador ha sido diseñado para proporcionar
calefacción adicional desde una pared en una construcción
nueva o una p1-ya existente.
El calentador se puede poner en funcionamiento desde
una pared usando el termostato de tensn de nea Broan
Modelo 86. Adquiera los controles en forma separada.
Planifique proporcionar al calentador la tensn de línea y
cable de enera eléctrica apropiados.
NOTA: La energía se puede tomar de un circuito cercano,
lo que dependerá del vatiaje requerido del calentador y
amperaje nominal del circuito.
El calentador se puede convertir a mitad de vatiaje para
evitar sobrecargar dichos circuitos.
BOLD ratings are factory wired. See "OPTIONAL WIR-
ING CONVERSION" section for wattage and voltage
conversion instructions.
Follow these basic steps when installing this heater.
Nail housing to studs.
Connect power cable.
Fasten heater assembly and grille to
housing. (FIG. 1)
PREPARE
THE HOUSING
1. Remove the retaining screw, unplug wiring har-
ness and lift heater assembly from housing. (FIG. 2)
2. Slide the wiring cover out of housing. (FIG. 3)
INSTALL
THE HEATER
(16"-ON-CENTER STUDS ONLY)
NOTE: Locate housing at least 6" from the floor and
any adjacent walls.
1. Choose which side of housing will be mounted
directly to a wall stud. Then insert a mounting
bracket from the opposite side into the channel
at the top of the housing. (FIG. 4)
2. Use measuring guide on side of housing to posi-
tion housing so that it will be flush with finished
wall. Drive to (2) nails through the holes on side
of housing and into stud. (FIG. 5)
3. Extend mounting bracket, level housing, and nail
to other stud. (FIG. 6)
(24"-ON-CENTER STUDS ONLY)
1. Choose which side of housing will be mounted
directly to a wall stud. From this side, push a
mounting bracket as far as possible into the chan-
nel at the top of the housing.
NOTE: Locate housing at least 6" from the floor
and any adjacent walls.
2. Use measuring guide on side of housing to posi-
tion housing so that it will be flush with finished
wall. Drive two (2) nails through the holes in side
of housing and into stud. (FIG. 7)
3. Secure the two (2) mounting brackets together
(with screw supplied). Level housing and nail to
opposite stud, as shown.
WIRE THE HEATER
(ALL INSTALLATIONS)
1. Feed electrical power cable through open knock-
out in corner of housing and attach with appropri-
ate connector. Allow 6" of wire inside of housing.
NOTE: Use other housing knockout when wiring
units in parallel. (FIG. 8)
2. Connect black to black, white to white. Use
grounding clip to attach green or bare wire to
housing. Replace wiring cover. (FIG. 9)
OPTIONAL WIRING
CONVERSIONS (FIGS. 10, 11, 12)
1. Conversion to half-wattage. (FIG. 10)
The heater will produce less heat and use less
electricity if converted to half-wattage.
Disconnect ONE of the black wires with an insu-
lated terminal (marked A) from the motor.
2. 120 VAC to 240 VAC Conversion (Factory-wired
120 VAC Models 120 and 124 ONLY) (FIG. 11)
These heaters can be converted to operate on
240 VAC.
1) Disconnect ONE of the black wires with an in-
sulated terminal (marked A) from the motor.
2) Disconnect the two (2) white wires with insu-
lated terminals from each other (marked B &
C). Do not remove wire (B) from beneath plas-
tic wire tie.
3) Connect the black wire (A) to white wire (C).
NOTE: When heater is converted from 120 VAC
to 240 VAC, half-wattage conversion is not pos-
sible.
FIG. 2
FIG. 3
FIG. 4
FIG. 5
MEASURING
GUIDE/GUIA
DE MEDIDA
FIG. 6
FIG. 7
FIG. 8
MEASURING
GUIDES/
GUIAS DE
MEDIDA
NAIL
HERE/
CLAVE
AQUI
GROUNDING CLIP/
SUJETADOR PARA
CONEXION A TIERRA
MODELOS
120
124
128
VOLTIOS
120
240
208
120
240
208
240
208
AMPS
8.33/4.16
4.16
3.61
12.5/6.25
6.25
5.41
6.33/4.16
7.21/3.61
VATIOS
1000/500
1000
750
1500/750
1500
1125
2000/1000
1500/750
BTU/HR
3413/1707
3413
2560
5120/2560
5120
3840
6827/3413
5120/2560
El cableado viene de brica para las corrientes nominales
en letras oscuras. Sección CONVERSIONES DE
CABLEADO ORIGINAL encontrará las instrucciones de
vatiaje y conversión de tensión.
Al instalar este calentador, siga estos pasos básicos:
Clave la caja en las vigas.
Conecte el cable de potencia.
Fije el conjunto del calentador y la rejilla a la caja.
(FIG. 1)
PREPARACION DE LA
CAJA
1. Saque el tornillo de retención, desenchufe el conjunto
de cables preconfigurado y saque de la caja el conjunto
del calentador. (FIG. 2)
2. Saque la cubierta de la caja. (FIG. 3)
INSTALACION
DEL CALENTADOR
(VIGAS DE 40,64 CM DE CENTRO SOLAMENTE)
NOTA: sie la caja a no menos de 15,24 cm (6 pulg.) del
piso o cualquier pared adyacente.
1. Elija cuál lado de la caja se va a montar directamente a
una viga de la pared. Después, meta un soporte de
montaje, desde el lado opuesto, dentro del canal en la
parte superior de la caja. (FIG. 4)
2. Use la guía de medida que está en el lado de la caja
para colocar ésta a nivel con la pared terminada. Pase
dos (2) clavos por los agujeros en el costado de la caja
y clávelos en la viga de la pared. (FIG. 5)
3. Extienda los soportes de montaje, nivele la caja, y clave
a la otra viga. (FIG. 6)
(VIGAS DE 60,96 CM (24 PULG.) DE CENTRO)
1. Elija cuál lado de la caja se va a montar directamente a
la viga de la pared. Desde este lado, meta un soporte de
montaje hasta lo más profundo que se pueda dentro del
canal en la parte superior de la caja.
NOTA: sitúe la caja cuando menos 15,24 cm (6 pulg.)
del piso y cualquier pared cercana.
2. Use la guía de medida que está en un costado de la
caja para colocar ésta para que quede a nivel con la
pared terminada. Pase dos (2) clavos por los agujeros
en el lado de la caja y clávelos en la viga de la pared.
(FIG. 7)
3. Fije los dos (2) soportes de montaje juntos (con el tornillo
que se incluye). Nivele la caja y clávela a la viga opuesta, tal
como se muestra.
CABLEANDO
EL CALENTADOR
(TODAS LAS INSTALACIONES)
1. Traiga el cable de energía eléctrica por la abertura del
disco removible en una esquina de la caja y fije con el
conector apropiado. Deje 15,24 cm (6 pulg.) de cable
dentro de la caja.
NOTA: use otro disco removible cuando cablee unidades
en paralelo. (FIG. 8)
2. Conecte negro a negro, blanco a blanco. Use el sujetador
para conexión a tierra para fijar el alambre verde o descubierto
a la caja. Coloque de nuevo la cubierta de cableado. (FIG. 9)
CONVERSIONES DE
CABLEADO OPCIONALES
(FIGS. 10, 11, 12)
1. Conversión a medio vatiaje (FIG. 10)
El calentador produce menos calor y usa menos
electricidad si se convierte a medio vatiaje.
Desconecte del motor UNO de los cables negros que
tienen terminal aislada (marcada A).
2. Conversión de 120 VCA a 240 VCA (Solamente
modelos 120 y 124 cableados de fábrica para 120 VCA).
(FIG. 11)
Estos calentadores de pueden convertir para que
funcionen en 240 VCA.


Produkt Specifikationer

Mærke: Broan
Kategori: Varmeapparat
Model: 120

Har du brug for hjælp?

Hvis du har brug for hjælp til Broan 120 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Broan Manualer

Broan

Broan 174F Manual

2 September 2024
Broan

Broan 124 Manual

2 September 2024
Broan

Broan 114 Manual

2 September 2024
Broan

Broan 112 Manual

2 September 2024
Broan

Broan 174 Manual

2 September 2024
Broan

Broan 174FT Manual

2 September 2024
Broan

Broan 170 Manual

2 September 2024
Broan

Broan 170FT Manual

2 September 2024
Broan

Broan 9810WH Manual

1 September 2024
Broan

Broan 128 Manual

1 September 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer