Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300290-01 Printed in U.S.A. Form No. 30MP-32SI Pg 1 6-25 Replaces: 30MP-31SI
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Mounting Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Minimum Area Requirements for Installation and
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
• UNVENTILATED AREA
• NATURAL VENTILATION TO OCCUPIED SPACE
• NATURAL VENTILATION TO THE OUTDOORS OR
UNOCCUPIED SPACE
• MECHANICAL VENTILATION
• MECHANICAL VENTILATION – REFRIGERANT
LEAK DETECTOR
Step 1 — Inspect Shipment . . . . . . . . . . . . . . . . . . . 30
Step 2 — Position the Unit . . . . . . . . . . . . . . . . . . . . 30
Step 3 — Place the Unit . . . . . . . . . . . . . . . . . . . . . . 30
Step 4 — Check Compressor Mounting . . . . . . . . . 30
• 30MP 017-031, 041, AND 046 UNITS
• 30MPW 033 UNITS
• 30MP 051-080 UNITS
Step 5 — Make Piping Connections . . . . . . . . . . . . 31
• SAFETY PRECAUTIONS FOR WORKING WITH
REFRIGERANT
• UNITS WITHOUT MANIFOLD
• 30MPA SYSTEM CONDENSER
• 30MPW/MPQ UNITS WITH NITROGEN CHARGE
• EVACUATION AND DEHYDRATION
• 30MPW/MPQ CONDENSER DESCRIPTION
• 30MPW/MPQ CONDENSER
• CONDENSER WATER CONTROL VALVE
• EVAPORATOR DESCRIPTION
• EVAPORATOR PIPING
• CHILLED WATER FLOW SWITCH
• FOR UNITS WITH WATER MANIFOLD
• DUAL CHILLER CONTROL OPTION
• MULTI-UNIT CHILLER CONTROL ACCESSORY
•AIR SEPARATION
Step 6 — Fill the Chilled Water Loop . . . . . . . . . . . 63
• WATER SYSTEM CLEANING
• FILLING THE SYSTEM
Step 7 — Make Electrical Connections . . . . . . . . . . 64
• 30MPA, MPW, MPQ CONTROL BOX
• 30MPE DISTRIBUTION PANEL
• UNBALANCED 3-PHASE SUPPLY VOLTAGE
SAFETY CONSIDERATIONS
Installing, starting up, and servicing air-conditioning equipment
can be hazardous due to system pressures, electrical components,
and equipment location.
Only trained, qualified installers and service mechanics should
install, start-up, and service this equipment.
Untrained personnel can perform basic maintenance functions,
such as cleaning coils. All other operations should be performed
by trained service personnel. Qualified installers and service tech
-
nicians are required to have been trained on the following topics
when installing and servicing air-conditioning equipment with
A2L refrigerant such as R-32:
1. Explosive potential of A2L refrigerants.
2. Potential ignition sources.
3. Safety measures for unventilated and ventilated rooms or
enclosures.
4. Refrigerant detectors.
5. Concept of sealed components and sealed enclosures
according to IEC 60079-15:2010.
6. Correct work procedures for the following:
a. Commissioning
b. Maintenance
c. Repair
d. Decommissioning
e. Disposal
See Controls and Troubleshooting Guide for complete guidelines.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
1. Follow all safety codes.
2. Keep quenching cloth and fire extinguisher nearby when
brazing.
3. Wear safety glasses and work gloves.
4. Use care in handling, rigging, and setting bulky equipment.
It is important to recognize safety information. This is the safety-
alert symbol
. When you see this symbol on the unit and in in-
structions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
AquaSnap
®
30MPA021-080, MPW017-080 and 30MPQ021-080
Liquid Chillers with Scroll Compressors
and PIC6 Controls