Læs gratis den danske manual til CyberPower BU800ELCD (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne vejledning er vurderet som hjælpsom af 32 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 16.5 anmeldelser. Har du et spørgsmål om CyberPower BU800ELCD, eller vil du spørge andre brugere om produktet?

Side 1/2
Copyright © 2022 Cyber Power Systems, Inc. All rights reserved.
K01-C000717-00
Users Manual
BU800ELCD
BU1000ELCD
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the
unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
contaminants. (See the specifications for the acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum
cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or
near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable
the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when
maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following :(1) UPS Unitx1; (2) User Manualx1
OVERVIEW
The BU800/1000ELCD provides automatic voltage regulation for inconsistent utility power, and provides battery backup during power
outages. The BU800/1000ELCD ensures consistent power to your computer system.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure
that the battery's maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery,
simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz
drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper
shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will
overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit
breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc). Avoid using
extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and
then turns the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to
ensure battery life.
BASIC OPERATION
1. Power Switch
Press the switch for 2 seconds to turn the UPS ON or OFF.
Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the
Alarm On. To turn the Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned off. To turn
the Alarm back on, quickly press the power button twice. You will hear a single short beep when the Alarm is turned on.
2. Led Indicators
LED is illuminated when the UPS is working.
3. Input Power Cord Connect to utility power.
4. Input Circuit Breaker (BU1000ELCD only)
The circuit breaker provides optimal overload protection.
5. LCD Display
High resolution and intelligent LCD display shows all the UPS information with icons and messages. For more information, please review
the “Definitions for Illuminated LCD Indicators” section.
6. AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against
surges and spikes.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
LED Alarm Condition
On Off Normal
Flash Beep Twice Utility Failure - The UPS is providing battery power to outlets.
Flash Rapid Beeping Utility Failure - The UPS is providing battery power. The rapid beeps indicate the battery will run out
of power shortly.
On/Flash Constant Tone Overload - Occurs when connected equipment exceeds the rating of the unit. Turn the UPS off and
unplug at least one piece of equipment from the UPS.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
The LCD display indicates a variety of UPS operational conditions.
All descriptions apply when the UPS is plugged into an AC outlet
and turned on or when the UPS is on battery.
Icon Description
Load Capacity
The meter displays approximate load level of the UPS outlets. Each bar represents 25%
of the load.
Normal Mode
When the icon is illuminated, the UPS works under normal condition.
When the icon blinks, the UPS transfers to AVR mode.
Battery Mode
The UPS is operating from its internal battery, supplying backup power to the connected
equipment.
Mute
When the icon is illuminated, the audible alarm has been turned off.
Overload
The icon appears and an alarm sounds to indicate the battery supplied outlets are
overloaded.
Output Voltage
The meter measures the AC voltage that the UPS is providing to the connected
equipment in normal mode and battery mode.
Input Voltage
The meter measures the input AC voltage of the UPS in normal mode.
Percentage
Estimated backup time percentage of the UPS based on current battery capacity and
load level.
Copyright © 2022 Cyber Power Systems, Inc. All rights reserved.
K01-C000717-00
Operation Modes and Warning
There are several operation modes and overload warning of the UPS. The LCD will automatically cycle the UPS information. The LCD
display will auto sleep after 5 minutes if no activity. If the LCD is off, press the button once and the LCD will be on again. The corresponding
LCD displays are as shown below.
LCD Display Figures Operation Mode
Line Mode: INPUT Voltage
The UPS is turned on and AC input power is normal. It supplies
power to the connected equipment. This meter displays the input
voltage of the UPS.
Line Mode: OUTPUT Voltage
The UPS is turned on and AC input power is normal. It supplies
power to the connected equipment. This meter displays the output
voltage of the UPS.
Line Mode: LOAD CAP.
The UPS is operating in line mode. This meter displays the
approximate load level of the UPS.
Line Mode: BATT. CAP.
The UPS is operating in line mode. This meter displays the
approximate charge level of the UPS’s internal battery.
Battery Mode
During a severe brownout or blackout, the Utility Power is absent
and the UPS switches to Battery Mode. The battery will supply
power to the connected equipment.
Line Mode – Overload
The UPS is operating on Line Mode. However the battery supplied
outlets are overloaded. Unplug some of your equipment from the
outlets until the Overload icon turns off and the alarm stops.
Battery Mode – Mute
Quickly press the power button twice to turn On or Off the audible
alarm.
TECHNICAL SPECIFICATIONS
Model BU800ELCD BU1000ELCD
Capacity (VA/W) 800/480 1000/630
Input
Voltage 220/230/240Vac
Nominal Frequency 50/60Hz
Output
On Battery Output Voltage 230Vac +/-10%
On Battery Output Frequency 50/60Hz +/-1%
Overload Protection Breaker / Fuse
Physical
Total UPS Receptacles 3 4
Dimensions (H x W x D)(mm) 91.5 x 158 x 240 110.5 x 190 x 290
Weight 4.1 kg 6.9 kg
Battery
Sealed Maintenance Free Lead Acid
Battery 12 V 24 V
Typical Recharge Time 8 Hours
Warning Diagnostics
Indicators Power On / Using Battery
LCD Displays Input / Output voltage, Load Capacity, Estimate BackupTime Percentage
Audible Alarms On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature 0 C to 40 C  
Operating Relative Humidity 0 to 90%
Management
Auto-Charger Yes
Auto-Restart Yes
TROUBLESHOOTING
Problem Possible Cause Solution
The UPS does not
perform expected
runtime.
Batteries are not fully charged. Recharge the battery by leaving the UPS plugged in.
Battery is slightly worn out. Contact CyberPower Systems Technical Support.
The UPS will not turn
on.
The unit is not connected to an AC outlet. The unit must be connected to a 220-240Vac outlet.
The battery is worn out. Contact CyberPower Systems Technical Support.
Mechanical problem. Contact CyberPower Systems Technical Support.
Outlets do not provide
power to equipment
Fuse is blown or breaker is tripped due to
overload.
Turn the UPS off and unplug at least one piece connected
equipment. Unplug the power cord of the UPS then contact
CyberPower Systems technical support. or press the circuit
breaker knob. Connect power cord then turn the UPS on.
Batteries are discharged Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a surge or spike.
Contact CyberPower Systems Technical Support.
PRODUCT REGISTRATION
Prompt product registration assures coverage under the Limited Warranty, and also allows
the opportunity to be notified of product enhancements, upgrades, and other announcements.
Registration is quick and easy.
Go to Product Registration page at www.cyberpower.com/product_registration
Cyber Power Systems, Inc.
www.cyberpower.com
For technical support, contact CyberPower at www.cyberpower.com/contact
Copyright © 2022 Cyber Power Systems, Inc. All rights reserved.