Læs gratis den danske manual til Denver TRC-1470 (32 sider) i kategorien Vejrstationer. Denne vejledning er vurderet som hjælpsom af 47 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 24 anmeldelser. Har du et spørgsmål om Denver TRC-1470, eller vil du spørge andre brugere om produktet?

Side 1/32
~P.1~
INDOOR & WIRELESS OUTDOOR THERMOMETER
WITH REAL TIME CLOCK & SNOOZE ALARM
MODEL: TRC-1470
INSTRUCTION MANUAL
1 . INTRODUCTION
Thank you for purchasing our In/Outdoor thermometer with wireless thermometer sensor and real time clock. The main unit
is designed to receive temperature signals from maximum 3 remote sensors in different locations, and it is also equipped with
a snooze alarm. To ensure proper operations, please read this instruction manual carefully and save it for future reference.
2 . DESCRIPTION OF BUTTONS
Main Unit
A . [SNOOZE/LIGHT] button
Activate the snooze function when an alarm sounds or turn on the backlight for 5 seconds.
B. [CLOCK] & [ALERT] button
Press the [CLOCK] side to display the real time clock, calendar or alarm time. When display the real time clock, press
and hold the [CLOCK] side for 2 seconds to activate the clock setting mode. When display the alarm time, press and
hold the [CLOCK] side for 2 seconds to enter the alarm setting mode.
Press the [ALERT] side to toggle to display high temperature alert and then low temperature alert for indoor thermom-
eter, channel 1, 2, 3 remote thermometers respectively and then return to normal thermo display mode.
Press & hold [ALERT] side for 2 seconds at the desired alert temperature display to enter its setting mode, use [+] / [-
] keys to change the settings, press [ALERT] again to confirm the setting or press no key for 10 seconds to auto-exit to
normal thermo display and confirm the setting.
C. [(°C/°F) MEM] button
Press the [(°C/°F)] side to select the temperature display in Celsius (°C) or Fahrenheit (°F).
Press the [MEM] side to toggle for max or min temperature memory reading for both IN & OUT thermometers. Press
ENG
~P.2~
and hold 2 seconds to clear both IN/OUT temperature memory.
D. [+] & [-] button
Press the [-] side to decrease the setting when enter setting mode of clock, alarm or temperature alert.
When display the alarm time, press [-] side to turn Daily Alarm on/off.
When display the temperature alert, press [-] side to turn the corresponding temperature alert on/off.
Press the [+] side to increase the setting when enter setting mode of clock, alarm or temperature alert.
E. [CHANNEL] button
Toggle to display remote thermo channel from channel 1, channel 2, channel 3 to Auto-scroll mode which alternately
display 3 channels;
Press and hold 2 seconds to activate searching mode for remote sensor;
Remote Sensor
The remote sensor has 3 function buttons inside the battery compartment.
a. [CH] button
After the battery installation, the LED blinks slowly every 1.5 seconds and channel number shows ‘1’ to indicate it is now
under channel setting mode and is set to channel 1 by default. If the user presses no key within ten seconds, the unit
will auto-exit the channel setting.
If the user press [CH] button once during the channel setting, the channel number is changed to ‘2’ to indicate the unit
is set to channel 2. If the user press [CH] button again, the channel number will be advanced to channel ‘3’ and so on.
b. [C/F] button (for sensor with LCD)
Press to toggle unit °C or °F
c. [RESET] button
Press to hardware reset the unit to factory setting
3. BATTERY INSTALLATION (Batteries NOT included)
BATTERY INSTALLATION FOR MAIN UNIT
a. Remove the battery door;
b. Insert 2 pieces AAA size 1.5V alkaline battery as indicate by the polarity;
c. Close the battery door.
BATTERY INSTALLATION FOR REMOTE SENSOR UNIT
a. Lift off the bracket stand of the remote sensor unit by releasing the 2 fixing snaps at the bottom;
b. Use a small Philips type screwdriver to remove the battery cover screws;
c. Insert 2 pieces of AAA size batteries according to the “+” and “-” polarity marks shown in the battery compartment and
then close the battery door.
WIRELESS REMOTE SENSOR REGISTRATION PROCEDURE
a. Insert p2-x2 AAA batteries first to the main unit. The temperature display shows —.-Cwhile the wave icon will keep
blinking for 2 minutes indicate the main unit is in sensor searching mode.
b. In a second step, insert the p2-x2 AAA batteries into the sensor unit. The LED on the front panel will start flashing at a rate
of one time per around 2 seconds indicates channel-1 is in use.
c. While the LED is flashing, press once the [CH] key will change the sensor channel setting to 2. Keep toggle on [CH] key
can change channel setting up to 3. The LED is blinking at a frequency to indicate the channel setting. i.e. continuous
blinks 2 times indicate channel-2 is selected.
4 . HOW TO SET TIME AND CALENDAR
a. Make sure the 1st line of the LCD displays the clock time, press & hold [CLOCK] button for 2 seconds to enter clock setting
mode. Flashing 24 hours will appear.
b. Press [ + ] or [ - ] button to switch between 24 hours and 12 hours format, and then press [CLOCK] button to confirm.
c. The hour digits will flash. Use the [ + ] button to increase by one hour or [ - ] button to decrease by one hour to your
desired hours. Holding down either button will change the increment rapidly. Press [CLOCK] button to confirm.
d. The minute digits will flash. Use the [ + ] button or [ - ] button to set your desired minutes. Holding down either button
will change the increment rapidly. Press [CLOCK] button to confirm.
e. The year digit will flash and Yr icon appears. Press [ + ] or [ - ] button to set your desired year. Press [CLOCK] button to confirm.
f. D and M icons will flash. Press [ + ] or [ - ] to select D M (Date Month) or M D (Month Date) format. Press [CLOCK]
button to confirm.
Note: Never set the channel to ‘4’ & ‘5’ which would not be applied in this model
NOTE: Please insert batteries for the main unit first, then the RF remote sensor.
Note: If user does not press any key for 10 seconds, it will exit the channel setting mode and transmit the RF signal.
The main unit will register the temperature reading.
Note: Every change of minute digit will automatically reset the seconds to zero.
Note: Year range is from 2000 to 2099.
ENG


Produkt Specifikationer

Mærke: Denver
Kategori: Vejrstationer
Model: TRC-1470

Har du brug for hjælp?

Hvis du har brug for hjælp til Denver TRC-1470 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vejrstationer Denver Manualer

Denver

Denver TRC-1470 Manual

5 Oktober 2022
Denver

Denver WS-72 Manual

5 Oktober 2022
Denver

Denver TRC-1460 Manual

5 Oktober 2022
Denver

Denver TRC-1480 Manual

5 Oktober 2022

Vejrstationer Manualer

Nyeste Vejrstationer Manualer

AcuRite

AcuRite 02022WB Manual

15 Januar 2025
Hama

Hama EWS-1500 Manual

13 Januar 2025
Technoline

Technoline WS 6740 Manual

13 Oktober 2024
AcuRite

AcuRite 02040 Manual

13 Oktober 2024
Alecto

Alecto WS-2500 Manual

13 Oktober 2024
Prologue

Prologue YT6981 Manual

12 Oktober 2024
Cotech

Cotech E0336WST4H4PR Manual

12 Oktober 2024
Irox

Irox EBR808C Manual

10 Oktober 2024