Læs gratis den danske manual til ELAC Protek PR-81B (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om ELAC Protek PR-81B, eller vil du spørge andre brugere om produktet?

Side 1/4
PR81-B 9-Outlet Smart Component Surge Protector Setup Guide
PRODUCT FEATURES
USING YOUR SURGE PROTECTOR
1. Ensure the power is o on the devices you will be connecting to the AC outlets on the surge protector.
2. Plug the surge protector into a properly grounded AC wall outlet and turn on the surge protector.
3. Check that the PROTECTED and GROUNDED blue LEDs are illuminated. If the PROTECTED LED is not illuminated, the surge protector is
not operating properly and will not protect yo protector ur connected devices. If the GROUNDED LED is not illuminated the outlet the surge
is connected to is not properly grounded and d electrician diagnose and troubleshoot tshould not be used. Please have a license he
aected wall outlet prior to use.
4. Plug your equipment into the outlets on the surge protector and power on your devices as usual.
5. USB devices can be charged/powered by e USB ports on the surge protector. The USBsimply connecting the USB power cord to th ports
deliver 5V and up to 2.4amps of power.
⑥ ⑦
⑩ ⑪
ELAC A
ELAC A
ELAC A
ELAC AELAC AMERICAS I
MERICAS I
MERICAS I
MERICAS IMERICAS INC.
NC.
NC.
NC. NC.
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K 1938 N. BATAVIA ST. SUITE K
ORANGE, CA 92865
ORANGE, CA 92865
ORANGE, CA 92865
ORANGE, CA 92865 ORANGE, CA 92865
Copyright 2021 ELAC Americas Inc.
Power Button—Press this button (.5 sec to 1 sec) to power on and
o the rear AC outlets. Press and hold for 10 seconds to factory reset
the unit.
Reboot Button—Pressing and holding the REBOOT button for 1.5
seconds will power cycle all outlets in Group 1.
Voltage / Current Button and Dimmer Button—The Voltage /
Dimmer button switches the display to show Voltage or Current. The
dimmer button adjusts the brightness of the display and other LEDs to
10%, 35%, 70% and 100%.
Display —Displays the voltage coming into the surge protector or
the current usage of all connected devices.
LED Indicators— Indicates the status of the surge protector
Protected / Clean Power
Protected / Clean Power
Protected / Clean Power
Protected / Clean PowerProtected / Clean Power—LED On: Outlets are Protected. LED
O: Surge Protection is not working and your connected devices
are not protected.
Ground OK
Ground OK
Ground OK
Ground OKGround OK—LED On: The wall outlet is properly grounded. LED
O: The wall outlet is NOT properly grounded and a licensed
electrician should be called to resolve the problem.
Reversed Polarity
Reversed Polarity
Reversed Polarity
Reversed PolarityReversed Polarity—LED O: The wall outlet polarity is correct.
LED On: Reverse polarity detected. Please contact a licensed
electrician to resolve the issue.
Unsafe Voltage
Unsafe Voltage
Unsafe Voltage
Unsafe VoltageUnsafe Voltage—LED O: Normal voltage detected. LED On:
Unsafe voltage detected and the surge protector will disconnect
power to your connected devices. Please consult a licensed
electrician.
Front AC Outlet—This front AC outlet is always on unless unsafe
voltage is detected.
Front Outlet Indicator—Front AC outlet power indicator.
Front Dual USB Charging Ports: 5V 2.4 Amp Total USB-A ports for
charging compatible devices.
Group 3 AC Outlets— These 4 outlets provide 70db of EMI/RFI
filtration and are perfect for source and lower current devices.
Group 2 AC Outlets— These 2 outlets provide 70db of EMI/RFI
filtration and are perfect for source and lower current devices.
Group 1 AC Outlets—These 2 outlets are designed for high current
devices such as audio amplifiers.
Overload Breaker—This breaker will trip when the surge protector
is overloaded. After resetting, please ensure the Protected/Clean
Power LED is On, if not, your surge protector needs to be replaced.
Rear USB Charging Ports: 5V 2.4 Amp Total USB-A ports for
charging compatible devices.
RISK OF ELECTRIC SHOCK – Use only in dry locations and only
indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT plug into 220V outlet or power source
DO NOT use with any aquarium equipment.
DO NOT connect to an ungrounded outlet.
DO NOT install this device if there is not at least 30 feet (10 meters),
or more of wire between the electrical outlet and electrical service
panel.
This device features internal protection that will disconnect the
surge protective component at the end of its useful life
(PROTECTED LED WILL TURN OFF) , but will maintain power to
outlet – WHICH WILL BE UNPROTECTED. If you don’t want your
equipment at risk, follow the manufacturer’s instructions for replac-
ing the device.
DO NOT use in any circumstance that would aect the operation or
reliability of life support equipment, any medical applications, or
patient care.
SAFETY INFORMATION TECHNICAL SPECIFICATIONS
Number of AC Outlets 9
Number of USB Ports 4—5V total 2.4A (2 Rear, 2 Front)
AC Outlets All 9 filtered with surge protection
Protection Modes Surge / Over Under Protection
Thermal Fuse Yes
Maximum Current 15 Amps
Line Voltage 120V @ 60Hz
Certification UL 1449, UL 1363, FCC, ICES
Max Energy Dissipation 3240 Joules
Max Spike Voltage / Current 6,000V / 165,000A
Response Time 1 Nanosecond
Filtration EMI / RFI G1: 40dB G2: 70dB
Over/Under Voltage Protection Over 135Vac / Under 95Vac
Bluetooth BLE (Bluetooth Low Energy) 2.4GHZ
App Control ELAC Protek App (Free Download)
App Capabilities Group Controlled Outlets, Scheduler,
Timer
ELAC A
ELAC A
ELAC A
ELAC AELAC AMERICAS I
MERICAS I
MERICAS I
MERICAS IMERICAS INC.
NC.
NC.
NC. NC.
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K
1938 N. BATAVIA ST. SUITE K 1938 N. BATAVIA ST. SUITE K
ORANGE, CA 92865
ORANGE, CA 92865
ORANGE, CA 92865
ORANGE, CA 92865 ORANGE, CA 92865
Copyright 2021 ELAC Americas Inc.
CONNECTING AND CONTROLLING THE PR81-B WITH THE ELAC PROTEK APP
1. Download and open the ELAC Protek App from either the iOS App Store or the Google Play Store.
2. In the App create an ELAC Protek account.
3. On the Home Screen Click on “Add Device”.
4. On the next screen choose Auto Scan (Top Right).
5. Press and Hold the Power Button on the PR81-B for 10 seconds until the unit reboots.
6. The Device will appear in the Available Devices Found screen.
7. Click Next or the + symbol and when prompted click “done”.
8. The PR81-B should now be connected to your phone/tablet and be controllable. This process can take up to one minute.
9. In the app you can now rename outlet groups, set timers, and schedules. Visit ELAC.COM for videos on how to get the most
out of your PR81-B.
ELAC ProteK App Screen Shots


Produkt Specifikationer

Mærke: ELAC
Kategori: Ikke kategoriseret
Model: Protek PR-81B

Har du brug for hjælp?

Hvis du har brug for hjælp til ELAC Protek PR-81B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret ELAC Manualer

ELAC

ELAC Muro OD-M61 Manual

18 Marts 2025
ELAC

ELAC Muro OD-M81 Manual

18 Marts 2025
ELAC

ELAC HDX21 Manual

6 September 2024
ELAC

ELAC Protek PR-71S Manual

1 September 2024
ELAC

ELAC PB12-W Manual

1 September 2024
ELAC

ELAC Protek PR-81B Manual

1 September 2024
ELAC

ELAC LS10 Manual

5 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer