Læs gratis den danske manual til Elkay EDFPBM117K (9 sider) i kategorien Vanddispenser. Denne vejledning er vurderet som hjælpsom af 36 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 18.5 anmeldelser. Har du et spørgsmål om Elkay EDFPBM117K, eller vil du spørge andre brugere om produktet?

Side 1/9
Page 1
EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,
EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC
97922C (Rev. G - 6/08)
SWIRLFLO fountains with FLEXI-GUARD
INSTALLATION, CARE & USE MANUAL
T M
T M
!
CAUTION
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
!
WARNING
:
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
!
WARNING
:
Service to be performed by authorized service personnel only.
INSTALLER
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an electrolysis effect occurring in the fountain. This may result in water which has a metallic
taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any
drain fittings provided by the installer should be made of plastic which will electronically isolate the
fountain from the remainder of the buildings plumbing circuits.
EDFPBM(V)117C EDFPBM(V)117RAC
EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,
EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC
Page 2
97922C (Rev. G - 6/08)
LEGEND
A = Water Inlet Location Left Or Right Side. 3/8 O.D. Unplated Copper Tube Connect.
B = Fountain Waste Location Left Or Right Side. Waste Is Shown in Wall But May Be Behind
Wall. 1-1/4 O.D. Drain (Trap Not Furnished)
C = Opening For Optional AP-99 Access Panel
Note: Reinforce The Wall In The Shaded Areas.
Figure 2 - Rough-in Assembly EDFPBM(V)117C
Figure 1 - Rough-in EDFPBM(V)117C
Optional