EmberGlo AR30 Manual


Læs gratis den danske manual til EmberGlo AR30 (10 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 2 anmeldelser. Har du et spørgsmål om EmberGlo AR30, eller vil du spørge andre brugere om produktet?

Side 1/10
Installation, Service Instructions & Parts
Quality Designed for Proven Performance
Printed in USA
8449 80
AVOID ERROR IN PARTS SELECTION. When ordering use
complete EMBERGLO Part Number and Description. Furnish
Model Number, Bill of Material Number and Serial Number (if
available) from the speci cation plate found on the product.
IMPORTANT: Availability of parts as well as speci cations are
item availability.
CAUTION: This steamer to be used with
distilled water only (demineralized). Without treated
water, deposits can build up in steam generators causing
reduced steam volume and eventual stoppage of steam pro-
duction. Clogged or limed steam generators caused by use
of non-distilled water will not be covered under the terms of
the warranty.
AR Series -Self Contained Water Reservoir and Pump - Stain-
less steel construction, Top injecting , portable, removable
water drawer, manual pump or timer, 6 - 3 wire cord.
Special Note: The AR Series requires distilled or demineral-
ized water. Clogged or limed generators caused by use of
non-treated water will not be covered under the terms of the
warranty.
Speci cations:
120 volts 60HZ AC 1500 watts, max 13 amp
240 volts 60HZ AC 1500 watts, max 6.3 amp
(240V model is Export Only and not UL listed)
Manual water pump operation
Closed generator
Drawer style steamer
!
EmberGlo
A Div of Midco® International Inc.
4140 West Victoria Street
Chicago, Illinois 60646
toll free 866.705.0514
tel 773.604.8700
fax 773.604.4070
web www.emberglo.com
e-mail sales@emberglo.com
Warranty form must be lled in and returned to EmberGlo to
validate warranty. See warranty page for return instructions.
This manual contains su cient information for installation of the
EmberGlo Steamer in normal locations.
In the United States, installation must conform with local codes.
PURCHASER: Retain these instructions for future use.
Post in a prominent location near the steamer.
CAUTION: Cooking equipment should be used in
an environment protected by an automatic re suppression
system. Consult the National Fire Protection Association NFPA
Code 96 or the latest edition of Standards for Installation of
Equipment for Removal of Smoke and Grease-Laden Vapors
From Commercial Cooking Equipment.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating
and maintenance instructions thoroughly before install-
ing or servicing this equipment.
Warranty
See the back of this manual for warranty.
This warranty does not apply to damages resulting from
accident, misuse, abuse or alteration.
No equipment may be returned without written authorization
from EmberGlo (or Midco) . Returned goods must be shipped
prepaid to the factory.
!
!
!
U
L
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of special notations
and have standard meanings throughout this manual. They are printed in all capital letters using a bold type face as shown
below, and preceded by the exclamation mark symbol. When you see the safety alert symbol and one of the safety information
terms as shown below, be aware of the hazard potential.
DANGER: Identi es the most serious hazards which will result in severe personal injury or death.
WARNING: Signi es a hazard that could result in personal injury or death.
CAUTION: Identi es unsafe practices which would result in minor personal injury or
product and property damage.
120
AR30
Front Open
Self Contained Water Supply
Counter Top Steamer
Half Size Pan
120V and 240V Models
(240V Model for Export ONLY)
AR30 Manual Operation with Water Pan 120V 5400305
AR30 Manual Operation with Water Pan 240V 5400306
Models Description Volts BOMs
2
EmberGlo A Division of Midco International Inc
8449 80
Maintenance
Daily as Required
Operation
Installation
1. Position steamer on level surface and plug power cord into 3-hole 120 volt AC grounded
receptacle. If an adapter is used, it must be grounded properly.
2. Pull out water pan and ll with distilled (NOT HOT OR BOILING) water to 1/4 from the top of
the water pan ba es; then close drawer. Unit is now ready for operation.
3. According to the Uniform Mechanical Codes per the No Hood Installation Required:
International Conference of Building O cials Code EmberGlo Steamers do not require a
separate hood for vapor produced during operation. Also, there are no requirements in NSF
Standard 4 (2006e) for steamers to have ventilation.
__________________________________________
1. Move toggle switch to ON position. The pilot indicating light remains on at all times.
Allow 15-20 minutes to reach operating temperature.
2. Open food drawer, place food in pan; close drawer and operate lever as required per cooking
guide.
3. At end of time cycle, open drawer and remove food.
4. Keep drawer closed when not in use.
5. To shut o unit move toggle switch to OFF position.
Caution: Operate lever to the left and return to vertical position. Rapid repeated
operation will over steam the unit. The amount of steaming necessary is determined by the
type and amount of food to be heated. For more than one shot, wait 15 seconds between
shots. A “shot” is one operation of the lever.
__________________________________________
The food pan is removed by lifting up. Clean the inside thoroughly and wipe the outside to remove
any material which might have accumulated.
- To remove the food drawer, pull the drawer out until it stops, release stop located at rear
underside of drawer to unlock, and pull out the frame. Wipe the drawer and frame clean and
return by inserting the drawer slide into the slide of the frame, then push the food pan to the
rear until the lock engages automatically.
__________________________________________
DANGER: READ AND UNDERSTAND THIS BULLETIN THOROUGHLY BEFORE
STARTING ANY TROUBLE SHOOTING. AN INADVERTENT SERVICE ERROR COULD RESULT
IN SEVERE PERSONAL INJURY OR DEATH. ONLY A TRAINED EXPERIENCED SERVICE
TECHNICIAN SHOULD ATTEMPT ANY REPAIR PROCEDURE.
Quali ed serviced agencies are available at most locations - Refer to EmberGlo listing of AUTHO-
RIZED SERVICE AGENCIES included in Standard Equipment Catalog.
Note: Before attempting service, unplug power cord. For service or examination, all “working parts”
of the steamer are exposed by removing rst the cabinet top, then the back. The wiring diagram and
spare clean out gasket is located on inside of back.
AR30 - Installation and Service
!
!
Service
Figure 1. Wiring for AR30 Steamer - 120V and 240V
L2
L1 Blk
G
Gnd
Blk
Wht
LEGEND
Symbol Description
Toggle Switch
Pilot Light
Thermostat
Generator
Over Heat
Protection Fuse
Terminal Strip
E
Service to be performed by qualified personnel only
Plug for 240 VAC to be Supplied by Installer
Material: (Outdoor/ Indoor Polyperm)
AR30 Wiring for
120/240 VAC Steamer


Produkt Specifikationer

Mærke: EmberGlo
Kategori: Ikke kategoriseret
Model: AR30

Har du brug for hjælp?

Hvis du har brug for hjælp til EmberGlo AR30 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret EmberGlo Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer