Inspection
The following items are inside the box:
UPS unit
User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Pow er
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6 hours
prior to initial use.
Plug in Equipment
Battery Backup Outlets(3)
Connect computer and monitor to the "Battery Backup" outlets.
These outlets provide battery backup, EMI ltering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets(3)
Connect a printer, fax machine, scanner or to the Surge protected” -
outlets. These outlets do not provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup sockets of UPS. The equipment may draw
signicantly power to overload the UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LED or LCD will light up. To turn o the UPS unit, press the power
switch again. Then, display will shut o.
1. LCD display or LED indicators
(Please check LED or LCD
section for the details)
2.
Power switch
3.
AC input
4.
Battery backup outlets
5.
Surge-protected outlets
6. USB port (option)
7.
Modem/phone/network surge
protection (option)
Operation Display
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on, it will enter this
mode for 4 seconds.
AC Mode
LCD information will be
displayed in the
following order when
LCD is touched.
1.
Output voltage
2.
Input voltage
3.
Load level
4.
Battery capacity
Overload
in AC
mode
icon will ash.
When overload occurs,
alarm will beep every
0.5 second.
Battery
Mode
When battery level is low,
icon will ash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the
following order when
LCD is touched.
1.
Output voltage
2.
Input voltage
3.
Load level
4.
Battery capacity
Overload
in battery
mode
icon will ash.
When overload occurs,
alarm will beep every
0.5 second.
NOTE: If backlight shuts o, you may activate it by touching the
screen.
Fault Code Table:
*Outlet type can be schuko,
UK or universal. 8.
Coax surge protection (option)
LED
Alarm
UPS Status
Green
O
The mains is normal and
UPS is operated
normally.
Yellow
Sounding every
10 seconds
Power failure occurs and
UPS is on battery mode.
Yellow
Sounding every
second
Low battery
Green
O
UPS is o.
Red
Continuously
sounding
UPS fault
LED on
LED O
LED flashing
Fault condition
LCD
Output short
circuited
Overload fault
Overcharge
Bad or severely
discharged
battery
High output
voltage fault
If fault alarm occurs, please call for service immediately.
SAVE THESE INSTRUCTION-This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user
replaceable parts. Only factory service personnel may
perform repairs.
This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by
laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the
connected loads does not exceed 3.5mA.
Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock
hazard as well as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to
properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS.
Do not place beverages or any other liquid-containing vessels
on or near the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive
contaminants). Avoid installing the UPS in locations where
there is standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or
vacuum cleaners to UPS.
Do not dispose of batteries in a re as they may explode.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell
battery.
A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed
when working on batteries:
1)
Remove watches, rings, or other metal objects from the hands.
2)
Use tools with insulated handles.
3)
Wear rubber gloves and boots.
4)
Do not lay tools or metal parts on top of batteries.
5)
Disconnect charging source prior to connecting or
disconnecting batteries terminal.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from
batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Release
electrolyte is harmful to the skin and eyes. It may be toxic.
Attention, hazardous through electric shock. Also with dis-
connection of this unit from the mains, hazardous voltage still
may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus
pole at the connectors of the battery when maintenance or
service work inside the UPS is necessary.
To reduce the risk of overheating the UPS, do not cover the
UPS' cooling vents and avoid exposing the unit to direct
sunlight or installing the unit near heat emitting appliances such
as space heater or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
WARNING: This is a category C2 UPS product. In a residential
environment, this product may cause radio interference, in
which case the user many be required to take additional
measures.
MODEL
400
600
800
CAPACITY
400VA/
240W
600VA/
360W
800VA/
480W
Input Voltage
220/230/240 VAC
Input Voltage Range
180-270 VAC
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type
12V/4Ah
12V/4.5Ah
12V/5Ah
Battery Number
1
1
1
Charging Time
8 hours recover to 90% capacity
Dimension (DxWxH)mm
305 x 158.5 x 95
Net Weight (kgs)
2.5
2.6
2.9
Humidity
0-90% RH @ 0-40°C non-condensing)
Noise Level
Less than 40dB
*Specications are subject to change without notice.
If any abnormal situations occur that are not listed above, please
call for service immediately.
Problem
Possible Cause
Solutions
Nothing is
displayed on
the panel.
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS
always on
battery mode.
Power cord loose.
Re-plug the power cord.
The UPS
continuously
beeps.
Please check the fault
code for the details.
Please check the fault code
for the details.
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specied in
the specs.
Battery defect.
Replace the battery.


Produkt Specifikationer

Mærke: FSP
Kategori: UPS
Model: NanoFit 600

Har du brug for hjælp?

Hvis du har brug for hjælp til FSP NanoFit 600 stil et spørgsmål nedenfor, og andre brugere vil svare dig




UPS FSP Manualer

FSP

FSP Nano 600 Manual

1 September 2024
FSP

FSP Nano 800 Manual

1 September 2024
FSP

FSP FP 600 Manual

31 August 2024
FSP

FSP FP 1500 Manual

31 August 2024
FSP

FSP NanoFit 800 Manual

31 August 2024
FSP

FSP FP 2000 Manual

31 August 2024
FSP

FSP NanoFit 600 Manual

31 August 2024
FSP

FSP iFP 600 Manual

31 August 2024

UPS Manualer

Nyeste UPS Manualer

APC

APC RBC150 Manual

2 April 2025
APC

APC RBC151 Manual

2 April 2025
APC

APC RBC145J Manual

29 Marts 2025
APC

APC RBC140J Manual

29 Marts 2025
APC

APC AP9922 Manual

29 Marts 2025
APC

APC RBC148 Manual

29 Marts 2025
Teltonika

Teltonika BAT120 Manual

30 Januar 2025
APC

APC BX1000M Manual

30 Januar 2025
APC

APC BX850 Manual

30 Januar 2025