GE Profile PNRQ20FBB Manual

GE Vandfilter Profile PNRQ20FBB

Læs gratis den danske manual til GE Profile PNRQ20FBB (84 sider) i kategorien Vandfilter. Denne vejledning er vurderet som hjælpsom af 40 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 20.5 anmeldelser. Har du et spørgsmål om GE Profile PNRQ20FBB, eller vil du spørge andre brugere om produktet?

Side 1/84
ge.com
Reverse Osmosis
101259 215C1174P004 49-50200 01-06 JR
Filtration System
PNRQ20FBL
PNRQ20FWW
PNRQ20FBB
PNRQ20FCC
Owners Manual
and Installation
Safety Instructions
Safety Instructions . . . . . . . . . . . . . .2
Specification Guidelines . . . . . . . . .3
Operating Instructions
About the RO System . . . . . . . . .4, 5
Installation Instructions
Tools and Materials Required . . . . .6
Before Beginning Installation . . .6, 7
Mounting System Installation . . . . .8
Feed Water Supply . . . . . . . . . . .9–12
Faucet Assembly . . . . . . . . . . . .13, 14
Battery Installation . . . . . . . . . . . .14
Filtration Drain Connection . .15, 16
Storage Tank and Startup . . . . . . .17
Care and Cleaning
Prefilter, Postfilter and
RO Cartridge Replacement . . . . . .18
Sanitization . . . . . . . . . . . . . . . . . .19
Water Test Kit . . . . . . . . . . . . . . . .20
Troubleshooting Tips . . . . . . .21–23
Consumer Support
Consumer Support . . . . .Back Cover
Parts List/Catalog . . . . . . . . . .24, 25
Warranty . . . . . . . . . . . . . . . . . . . .26
Manuel d’utilisation
et d’installation
Manual del propietario
y instalación
La section française commence à la page 27
Osmose Inversée
Système de Filtration
La sección en español empieza en la página 55
Ósmosis Inversa
Sistema de Filtración
Tested and Certified by NSF International to
NSF/ANSI Standard 58. For the reduction of the
claims specified, see the Performance Data Sheet.
Essayé et certifié par NSF International
conformément aux normes 58 NSF/ANSI. Pour
la réduction des caractéristiques indiquées,
consultez la feuille de données de rendement.
Probado y certificado por NSF International por
cumplir con el estándar 58. Para la reducción de
reclamos especificados, ver la hoja de datos de
desempeño.
Write the model and serial
numbers here:
Model # __________________
Serial # __________________
You can find them on the bracket.
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install the
Reverse Osmosis system. Using a qualified installer
is recommended.
If house water pressure is over the maximum
(120 pounds per square inch), install a pressure
reducing valve in the water supply line to the
Reverse Osmosis system.
Be sure the water supply conforms with the
Specification Guidelines. If the water supply conditions
are unknown, contact your municipal water company
or your local health department for a list of
contaminants in your area and a list of laboratories
certified by your state to analyze drinking water.
WARNING: Before using the Reverse Osmosis
system for the first time, the system must be
purged. The Reverse Osmosis cartridge contains
a food grade preservative that must be purged
from the system. The preservative will give product
water an unpleasant taste and odor.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. Systems certified for cyst reduction may
be used on disinfected water that may contain
filterable cysts.
This system has been tested for the treatment of
water containing pentavalent arsenic (also known
as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces
pentavalent arsenic, but may not remove other
forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine
residual or on water supplies that have been
demonstrated to contain only pentavalent arsenic.
Treatment with chloramine (combined chlorine)
is not sufficient to ensure complete conversion of
trivalent arsenic to pentavalent arsenic. Please see
the Arsenic Facts section of the Performance Data
Sheet for further information.
This reverse osmosis system contains a replaceable
component critical to efficiency of the system.
Replacement of the reverse osmosis component
should be with one of identical specifications, as
defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance.
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
Install or store where it will not be exposed to
temperatures below freezing or exposed to any type
of weather. Water freezing in the system will
damage it. Do not attempt to treat water over 100°F.
Do not install on HOT WATER. The temperature
of the water supply to the Reverse Osmosis system
must be between the minimum of 40°F and the
maximum of 100°F. See the Specification Guidelines.
Extended non-use of the Reverse Osmosis system.
If the system has not been used for one week or
more, open the RO water faucet and allow the
system to drain. Close the RO water faucet and
allow the system to regenerate the water supply.
Recommended installation is under the sink.
However, the unit can be installed in a remote
location, up to 20 feet away from the sink.
However, additional materials will be required,
including additional tubing and extension
phone cable. This extension phone cable
must be 6 conductor wire and connectors;
typical 4 conductor wire will not work. See parts
list to obtain additional materials from GE.
Locating the tank on a basement floor, with the
faucet at a first floor sink may result in some loss
of flow rate and capacity (approximately 20%).
Installing a second tank will improve this
performance. An RVKIT can be used.
If Reverse Osmosis system is connected to a
refrigerator icemaker, a special icemaker
connection kit is required (RVKIT). Do not use
copper tubing for the connection between the
Reverse Osmosis system and the refrigerator.
WARNING: Discard all unused parts and packaging
material after installation. Small parts remaining after
the installation could be a choke hazard.
Sanitize upon installation of the Reverse Osmosis
system and after servicing inner parts, including
replacement of prefilter, postfilter and Reverse
Osmosis cartridge. It is important to have clean
hands while handling inner parts of the system.
See the Sanitizing the Reverse Osmosis System section.
This Reverse Osmosis system contains a replaceable
treatment component critical for effective
reduction of total dissolved solids. This product
water shall be tested periodically to verify that the
system is performing satisfactorily. See the About
the Water Test Kit section.
BE SURE TO FOLLOW ALL APPLICABLE STATE
AND LOCAL CODES.
WARNING! For your safety, the information in this manual must be followed to minimize the risk of
property damage or personal injury.
SAFETY PRECAUTIONS
PROPER INSTALLATION AND MAINTENANCE
This Reverse Osmosis system must be properly installed and located in accordance with the
Installation
Instructions before it is used.
Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
2


Produkt Specifikationer

Mærke: GE
Kategori: Vandfilter
Model: Profile PNRQ20FBB

Har du brug for hjælp?

Hvis du har brug for hjælp til GE Profile PNRQ20FBB stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vandfilter GE Manualer

GE

GE GXRLQK Manual

21 Februar 2025
GE

GE Profile PNRQ15RBL Manual

9 December 2024
GE

GE GX1S15C Manual

13 Oktober 2024
GE

GE GXSF18G Manual

2 September 2024
GE

GE GX1S01C Manual

2 August 2024
GE

GE GNWH38S Manual

31 Juli 2024
GE

GE GXCF03KWW Manual

25 Juli 2024

Vandfilter Manualer

Nyeste Vandfilter Manualer

Scotsman

Scotsman SSM2-P Manual

14 Juni 2025
Scotsman

Scotsman SSM3-P Manual

14 Juni 2025
Emga

Emga 340001 Manual

31 Marts 2025
Everpure

Everpure H-1200 Manual

21 Februar 2025
Philips

Philips AWP1812 Manual

7 Februar 2025
Oase

Oase AquaSkim 20 Manual

3 Februar 2025
Seagull

Seagull IV X-1F Manual

16 Januar 2025
AstralPool

AstralPool Oslo Manual

11 Januar 2025