WXF601
LED signalization light, red + green
lighting
Voyant de signalisation à LED, rouge +
WXF602
LED signalization light, blue lighting
Voyant de signalisation à LED, bleu
WXF603
LED signalization light, white lighting
Voyant de signalisation à LED, blanc
Safety instructions
Electrical equipment may only be installed and
assembled by a qualified electrician in accordance
with the relevant installation standards, guidelines,
regulations, directives, safety and accident prevention
regulations of the country.
Hazard due to electric shock. Disconnect before
working on the device. Take into account all circuit
breakers that supply dangerous voltages to the
device.
Failure to comply with these instructions may result in
damage to the device, fire, or other ha-zards.
Device is not suitable for use in safety technology or
as emergency light.
Hazard of fire. Do not operate device on a dimmer.
The lamps are not dimmable.
If several devices are to be connected via the contact
operating modes, it is absolutely essential that all
devices are operated via the same phase. Otherwise
devices may be destroyed.
Do not operate device on an electronic switch insert
(e.g. Tronic or Triac insert). The switch insert may be
damaged.
These instructions are an integral component of the
product and must be retained by the end user.
WXF60x
gallery
Technical characteristics
Rated voltage 230 Vv
Mains frequency 50/60 Hz
Number of LEDs 4
Connection single stranded 2,5 mm²
Operating temperature -15° ... +40°C
LED signalization light, WXF601
Power consumption max. 2 Watt
195 ... 265 V
v, 50/60 Hz
Power factor approx. 0.9
LED signalization light, WXF602
Power consumption per colour max. 0.5 Watt
195 ... 265 V
v, 50/60 Hz
LED signalization light, WXF603
Power consumption max. 1 Watt
230V
v, 50 Hz
Power factor approx. 0.17
LN
L
WXF003 WXF602, WXF603
N
LED signalization light, blue + white lighting
WXF602 /WXF603
Voyant de signalisation à LED, éclairage bleu +
blanc WXF602 /WXF603
L
N
WXF003 WXF601
LED signalzation light, red + green lighting
WXF601
Voyant de signalisation à LED, rouge + vert
WXF601
Caution
Fire hazard if the device is connected to
DC voltage.
Only connect to AC voltage
230 , 50 Vv Hz.
Utilisable partout en Europe
M
et en Suisse
Comment éliminer ce produit
(déchets d’équipements
électriques et électroniques).
(Applicable dans les pays de l’Union Européenne et
aux autres pays européens disposant de systèmes de
collecte sélective).
Ce symbole sur le produit ou sa documentation indique
qu’il ne doit pas être éliminé en n de vie avec les autres
déchets ménagers. L’élimination incontrôlée des déchets
pouvant porter préjudice à l’environnement ou à la santé
humaine, veuillez le séparer des autres types de déchets
et le recycler de façon responsable. Vous favoriserez ainsi
la réutilisation durable des ressources matérielles.
Les particuliers sont invités à contacter le distributeur
leur ayant vendu le produit ou à se renseigner auprès
de leur mairie pour savoir et comment ils peuvent se
débarrasser de ce produit an qu’il soit recyclé en
respectant l’environnement.
Les entreprises sont invitées à contacter leurs fournisseurs
et à consulter les conditions de leur contrat de vente. Ce
produit ne doit pas être éliminé avec les autres déchets
commerciaux.
Usable in all Europe
M
and in Switzerland
Correct Disposal of this
product
(Waste Electrical & Electronic
Equipment)
z
(Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it should not be disposed with other
household waste at the end of its working life. To prevent
possible harm to the environment or human health from
uncontrolled waste disposal, please separate this from
other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where
they purchased this product, or their local government
ofce, for details of where and how they can take this
device for environmentally safe recycling.
Business users should contact their supplier and check
the terms and conditions of the purchase contract. This
product should not be mixed with other commercial
wastes of disposal.
Consignes de sécurité
L‘installation et le montage d‘appareils électriques
doivent être effectués uniquement par des électriciens
qualifiés, en conformité avec les normes d’installation
et dans le respect des directives, dispositions et
consignes de sécurité et de prévention des accidents
en vigueur dans le pays.
Risque d’électrocution. Déconnecter toujours
l’alimentation secteur avant d’intervenir sur l’appareil.
Couper en particulier tous les disjoncteurs qui
fournissent des tensions dangereuses à l’appareil ou
à la charge.
Le non-respect de ces instructions peut entraîner des
dommages sur l’appareillage, un incendie ou d’autres
dangers.
L’appareil ne convient pas pour une utilisation dans
la technique de sécurité ou en tant que lampe de
secours.
Risque d’incendie. Ne pas faire fonctionner les
lampes LED sur un variateur. Les lampes LED ne
sont pas dimmables.
Les lampes LED ne doivent pas être utilisées
sur un mécanisme interrupteur électronique (par
ex. un mécanisme Tronic ou Triac). Cela pourrait
endommager les mécanismes interrupteur
.
Ces instructions font partie intégrante du produit et
doivent être conservées chez l’utilisateur final.
Caractéristiques techniques
Tension nominale 230 Vv
Fréquence réseau 50/60 Hz
Nombre de LED 4
Raccord unifilaire 2,5 mm²
Température ambiante -15° ... +40°C
Voyant de signalisation à LED, WXF601
Puissance consommée max. 2 Watt
195 ... 265 V
v, 50/60 Hz
Puissance absorbée approx. 0.9
Voyant de signalisation à LED, WXF602
Puissance consommée per colour max. 0.5 Watt
195 ... 265 V
v, 50/60 Hz
Voyant de signalisation à LED, WXF603
Puissance consommée max. 1 Watt
230V
v, 50 Hz
Puissance absorbée approx. 0.17
Attention
Risque d incendie en cas de raccordement
de l
appareillage à une tension continue.
Raccorder exclusivement à une tension
alternative 230 , 50 Vv Hz.
Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com 6LE005624BHager 06.211


Produkt Specifikationer

Mærke: Hager
Kategori: Lys
Model: WXF601

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager WXF601 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Lys Hager Manualer

Hager

Hager EE635 Manual

9 August 2025
Hager

Hager WXF601 Manual

9 August 2025
Hager

Hager EE638 Manual

9 August 2025
Hager

Hager GS30003020 Manual

9 August 2025

Lys Manualer

Nyeste Lys Manualer

Lucide

Lucide Ramin Manual

12 November 2025
SDJ

SDJ J-Wash 400 Manual

12 November 2025
Antari

Antari F-7 SMAZE Manual

11 November 2025
Sagitter

Sagitter Club DOT Manual

11 November 2025
XCell

XCell Worklight Flip Manual

11 November 2025
KAWOTI

KAWOTI 21334 Manual

11 November 2025
SDJ

SDJ Smart Wash Plus Manual

11 November 2025
SDJ

SDJ J-Beam 150 Manual

11 November 2025