MODEL: T176
24 HOUR DIAL TIME SWITCH
WITH “SKIPPER
®
1 NO - 1 NC CONTACTS
TYPE 1 INDOOR USE ONLY
MAY BE WIRED AS SINGLE POLE DOUBLE THROW (SPDT)
40 A RESISTIVE, INDUCTIVE, TUNGSTEN
OR 1000 VA PILOT DUTY PER POLE 120/208/277 VAC;
16 A ELECTRONIC BALLAST, 277 VAC
WARNING
Risk of Fire or Electric Shock
Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
Installation and/or wiring must be in accordance with national and local electrical code requirements.
Use wires rated at least 90°C - COPPER conductors ONLY.
Replace plastic insulator covering terminals before powering ON.
KEEP DOOR CLOSED AT ALL TIMES when not servicing.
NOTICE
• Rotate timer dial clockwise only.
• Do not move the clock hands on the timer. Moving the clock hands can damage the timer.
AVERTISSEMENT
Risque d’incendie ou de choc électrique
Utiliser des fils classés 90°C minimum - Conducteurs en CUIVRE UNIQUEMENT.
UL
HOLOGRAM
LABEL
LR3730
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE
INSULATION CLEARS
PRESSURE PLATE
MINIMUM
COPPER
WIRE SIZE
(AWG)
MAX.
LOAD
(AMP)
MIN.
INSUL-
ATION
TEMP(°C)
75°C INSULATION MAX. MOTOR
LOAD (HP)
SINGLE PHASE
3 PHASE
120 V. 240 V. 208 V.
240 V.
14
12
10
8
15
20
30
40
90
90
90
90
1/2
1
2
-
2
2 1/2
3
5
N/A
N/A
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
154--02075
PROGRAMMING INSTRUCTIONS
1. TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time
(AM or PM) when and operations are desired, tighten tripper screws firmly. For additional ON OFF
tripper pairs on order 156T1948A.CLOCK-DIAL
2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact
time-of-day on the (the time now, when switch is being put into operation) to the CLOCK-DIAL
pointer. DO NOT MOVE POINTER.
3. TO SKIP OPERATION(S) ON SELECTED DAY(S): SKIPPING SCREW(S) SKIPPER WHEEL Insert in
for day(s) automatic operation(s) is/are NOT required. Tighten screws firmly. Move MANUAL
LEVER “OFF” to and rotate to locate correct day-of-week opposite SKIPPER WHEEL DAY
ARROW--”YESTERDAY” if ON/CUTOUT TRIPPER has not yet advanced wheel “TODAY” if it has.
OPERATING INSTRUCTIONS
TO OPERATE SWITCH MANUALLY: MANUAL LEVER Move below CLOCK-DIAL left or right as
indicated by arrows. This will not effect next operation.
CAUTION: TO AVOID SLOW SWITCH ACTION FAILURE, DO NOT OPERATE
SWITCH MANUALLY NOR PLACE A TRIPPER 4 HOURS PRIOR TO
ON/CUTOUT TRIPPER SWITCHING.
IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming
instructions.
FROM
208V
240V
OR
277V
WIRING INSTRUCTIONS: Remove 1/2 inch of insulation from wire ends. Tighten terminal screws firmly (2-18 in-lbs).
Use solid or stranded COPPER only. May use two wires of the same size and type.To wire switch follow conductors
diagram above. To wire as SINGLE POLE NORMALLY CLOSED, move clock motor lead from terminal 3 to 1, and connect
LINE to 1, LOAD to 2. To wire as SINGLE POLE DOUBLE THROW, install jumper (the same gauge as Line wire) between 2
and 3 and connect LINE to 2, LOADS to 1 and 4. NEUTRAL connection always as shown.
DAY
ARROW
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
ON/CUTOUT
TRIPPER
SKIPPER
WHEEL
SKIPPING
SCREW
CLOCK MOTOR: 208-277 VAC, 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER
REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
CLOCK
MOTOR
GROUND
A
1
2
3
4
N
TO
LOAD
GRD
LINE
TYPICAL WIRING SINGLE POLE NORMALLY OPEN
SEE WIRING INSTRUCTIONS BELOW FOR OTHER TYPES
WIRING DIAGRAM