MODEL: T1905HD
24 HOUR PROGRAM TIME SWITCH
FOR UP TO 48 TIMING OPERATIONS
SINGLE POLE DOUBLE THROW
SWITCH RATING: 20 AMP. 125-480 VOLTS A.C. 1/2 HP-125V 1 HP-250V.
WIRING INSTRUCTIONS
This Time Switch can be wired to control two circuits as Single Pole
Double throw, or to control one circuit as Single Pole Single Throw,
either normally open (NO) or normally closed (NC). To wire switch
see wiring diagram above.
1. TO PROGRAM TIME SWITCH, Pivot tripper(s) as shown in Fig. 1 to an
inward position or outward position to set desired time(s) of operation(s).
• ON TIME: First tripper (pivoted in an inward position) turns ON the
load for 16-20 minutes. Each additional tripper will lengthen the on
time by 15 minutes.
• OFF TIME: First tripper (pivoted in an outward position) turns OFF
the load for 10-14 minutes. Each additional tripper will lengthen the
OFF time by 15 minutes.
• FOR NC Circuit OPERATION: The tripper pivot position is
reversed.
2. SET TIME-OF-DAY: Turn dial in clockwise direction and align the
exact time-of-day (the current time) to time arrow on the dial.
OPERATING INSTRUCTIONS
TO CONTROL LOADS MANUALLY, Move manual lever (See Figure
1) up. This lever will close normally open circuit and open the normally
closed circuit. To return to automatic control, move lever back to its origi-
nal position.
IN CASE OF POWER FAILURE, reset dial. See step (2) of programming
instructions.
INTERMATIC INCORPORATED
LIBERTYVILLE, ILLINOIS 60048
154--03100 MADE IN MEXICO
TIME DIAL
INSULATOR
MANUAL
LEVER
CAP
NUTS
CLOCK
MOTOR
NEUTRAL
N.C. CIRCUIT
N.O. CIRCUIT
FIG. 1 WIRING DIAGRAM
CLOCK
COM.
N.C.N.O.
N.C.
LOAD
NO.
LOAD
CLOCK MOTOR: 125 VOLTS - 60 HZ.
LR3730
OFF POSITION
(OUTWARD)
ON POSITION
(INWARD)
TIME
ARROW
LINE
Turn power off at main panel before servicing this switch or the equipment
it controls.
Use min. 75˚C copper conductors only. Reinstall insulator after wiring.
WARNING
Risk of Fire or Electrical Shock
Produkt Specifikationer
Mærke: | Intermatic |
Kategori: | bryter |
Model: | T1905HD |
Har du brug for hjælp?
Hvis du har brug for hjælp til Intermatic T1905HD stil et spørgsmål nedenfor, og andre brugere vil svare dig
bryter Intermatic Manualer

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

6 Juni 2025
bryter Manualer
- bryter Vemer
- bryter InLine
- bryter Smart-AVI
- bryter Finder
- bryter APC
- bryter Hager
- bryter Extron
- bryter Lancom
- bryter Televés
- bryter Ecler
- bryter Adder
- bryter QNAP
- bryter Advantech
- bryter DEHN
- bryter Intellinet
Nyeste bryter Manualer

7 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

3 Juni 2025

2 Juni 2025

1 Juni 2025

1 Juni 2025

1 Juni 2025

1 Juni 2025