JUNG 244-110 Manual


Læs gratis den danske manual til JUNG 244-110 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om JUNG 244-110, eller vil du spørge andre brugere om produktet?

Side 1/5
Light Management Dimmer for 110 - 127 V
Incandescent Lamps
Ref-no.: 244-110
Operating Instructions
Dimmer for 110 - 127 V Incandescent
Lamps
Attention:
Electrical equipment must be installed and fitted only by qualified
electricians and in observance of the current accident prevention
regulations.
To prevent electric shocks, the device must be safely disconnected
from the mains before performing any work on the device itself or
on the load (circuit-breaker cut out).
Not suitable for safe disconnection of the mains.
Do not connect any electronic lamps, e.g. switchable or dimmable
compact fluorescent lamps or LED lamps. Device can be damaged.
Any non-observance of the fitting instructions may cause fire or
other hazards.
The basic brightness for use in 60-Hz-networks may be adjusted by
qualified electricians only. Any unqualified tampering involves the
risk of electric shocks.
Only tools approved for work on devices under tension may be used
for this purpose.
Before performing the adjustment, it must be ensured that adjacent
devices under tension (e.g. socket inserts in multiple combinations)
are disconnected from the mains or if this is not possible
protected against direct contact.
Stand: Feb-10 325 267 13
Light Management Dimmer for 110 - 127 V
Incandescent Lamps
Ref-no.: 244-110
2. Function
Dimmer for incandescent lamps for switching and dimming of:
110 - 127 V AC incandescent lamps
110 - 127 V AC halogen lamps
Important:
The connection of transformers is not allowed.
Switching and dimming is obtained by depressing and by turning the
control knob.
Depressing the control knob: ON OFF
Turning the control knob: Dimming
3. Short-circuit protection
ensured by fine-wire fuse: F 4 / 250 E
In the event of malfunctions check first the fuse.
Use only original fuses.
4. Installation
The dimmer for incandescent lamps consists of the dimmer base (1) with
cover and control knob (2) (see fig. A).
Fig. A
The dimmer (1) is installed in a ush-mounting box acc. To DIN 49073.
Important:
The overall load connected to the dimmer must not exceed 400 W.
The rated maximum load can consist of a mix of the different types of
load specified.
A minimum load of 60 W is necessary to prevent flickering of the lamps
connected.
Depending on the installation, the maximum rated power must be
reduced by:
10% for every 5°C above an ambient temperature of 25°C
15% for incorporation into wooden, plasterboard or hollow walls
20% for incorporation into multiple combinations
Observe the technical connection requirements of the power supply
companies.
2


Produkt Specifikationer

Mærke: JUNG
Kategori: Ikke kategoriseret
Model: 244-110

Har du brug for hjælp?

Hvis du har brug for hjælp til JUNG 244-110 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret JUNG Manualer

JUNG

JUNG RCDME2022 Manual

30 Juli 2025
JUNG

JUNG RCD2023 Manual

30 Juli 2025
JUNG

JUNG RCD2021 Manual

30 Juli 2025
JUNG

JUNG RCD2044 Manual

30 Juli 2025
JUNG

JUNG RCD2022 Manual

30 Juli 2025
JUNG

JUNG RCDME2044 Manual

30 Juli 2025
JUNG

JUNG 1711 DE Manual

30 Juli 2025
JUNG

JUNG MA1000AD4 Manual

20 Juli 2025
JUNG

JUNG SM1608 Manual

19 Juli 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Roccat

Roccat Recon Cloud Manual

15 September 2025
AREXX

AREXX PRO-77IR Manual

15 September 2025
Biltema

Biltema 29-903 Manual

15 September 2025
Brandson

Brandson 306618 Manual

15 September 2025
Daewoo

Daewoo AVS1412 Manual

14 September 2025
Neutrik

Neutrik NO4SBB2D-A Manual

14 September 2025
Neutrik

Neutrik NO12SABB3Q-A Manual

14 September 2025
JILONG

JILONG JL097205NPF Manual

14 September 2025