TRONIC amplifier, built-in
Light Management
TRONIC amplifier, built-in
Art.-No.: 247 EB
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent
lamps or LED lamps. Device can be damaged.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
picture 1
(1) Power extension
(2) Load connection
(3) Dimmer connection
3 Function
Intended use
- Output extension of TRONIC dimmers, which work according to the phase section
principle.
- Output extension of universal dimmers, which have detected an ohmic or capacitive basic
load.
Do not operate universal dimmers with an inductive load.
- Connection of filament lamps, HV halogen lamps and TRONIC transformers with halogen
lamps.
- Suitable for mixed operation up to the specified output (see chapter 5.1. Technical data)
- Do not operate the corresponding dimmers without a load.
- Installation in false ceilings or surface mounting
1/4
82539913
J:0082539913 11.08.2010
Product characteristics
- Connection of multiple power extensions to one dimmer possible
- Operation using upstream dimmer
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
i Brightness differences between the lighting at the dimmer and the lightning at the power
extension are possible.
4 Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting and connecting the power extension
i Use the same external conductor for dimmers and power extensions. Do not swap L and N
on the power extension. Otherwise, there is the risk of malfunction.
picture 2
(1) Power extension
(4) Dimmer
o Fit the power extension.
i Minimum diameter of ceiling opening for installation in false ceilings: 63 mm.
o Connect the power extension according to the connection diagram (picture 2).
i In the case of lighting systems with an output of more than 3500 W/VA, the installation
must divided across two circuit breakers with the same external conductor.
o If multiple circuit breakers supply dangerous voltages to the device or load, couple the
circuit breaker to ensure tripping.