SMOKE ALARM DESCRIPTION
Model KF10, KF10LL Ionisation 230V AC smoke alarm with 9V
battery back-up and Hush Button
Model KF10R Ionisation 230V AC smoke alarm with recharge-
able battery backup and Hush Button
Model KF20,KF20LL Optical 230V AC smoke alarm with 9V
battery back-up with Hush Button
Model KF20R Optical 230V AC smoke alarm with rechargeable
battery back-up and Hush Button
SMOKE ALARM FEATURES
Interconnects with up to 23 other models, KF1, KF1R, KF2, KF2R, KF3, KF3R,
KF10, KF10LL, KF10R, KF20, KF20LL, KF20R, KF30, KF30LL, KF30R, 4870,
4881, 4973, 4985, 4892, 4899, 1SFW, 1SFWR, 2SFW, 2SFWR, 3SFW, 3SFWR,
and 4MCO and 4MDCO Mains CO alarms. Unique power connector prevents
interconnection with incompatible smoke alarms or security systems.
Tamper-resist bracket quickly snaps into place and serves as a safeguard
against tampering.
Multi-purpose green and red LEDs indicate that the smoke alarm is receiving
AC power, working under normal operation, in alarm, or under Hush Button.
Loud alarm horn—85 decibels at 3 metres (10 feet)—sounds to alert you of
an emergency.
Test button checks smoke alarm operation.
All models feature Hush Button, which, when activated, quiets unwanted alarms
for up to 9 minutes.
Models KF10, KF10LL, KF20 and KF20LL will not attach to the mounting
bracket if a battery is not in the battery pocket. These models will also sound
a short beep about once a minute if the battery is weak or improperly con-
nected.
Models KF10R , KF20R , KF10LL and KF20LL have lithium batteries that will
last the life of the alarm and a tamper-proof locking screw option.
Models KF10R and KF20R include permanent rechargeable lithium
batteries.
Operating temperature: 0°C to 40°C
Operates up to 93% humidity (non-condensing)
Storage and Transport Conditions: -20° C to +60° C, 5-95%RH
(non-condensing)
Models KF10, KF10R, KF10LL are designed to detect products of
combustion using ionisation technology. This product contains 0.9
microcurie of Americium 241, a radioactive material.
NOTE: Additional markings can be found on the back of the unit.
IMPORTANT SAFETY INFORMATION
PLEASE READ AND SAVE THESE
INSTRUCTIONS
W A R N I N G
DO NOT paint or cover the smoke alarm with tape.
This smoke alarm should be out of the reach of children.
AC smoke alarms require constant 230V AC, 50Hz power to operate
properly. Mains-only powered smoke alarms WILL NOT work if AC power is
not connected or has failed or been interrupted for any reason. Models
KF10, KF10LL and KF20, KF20LL require a working 9-volt battery to operate
properly in the event of a power failure. Models KF10R and KF20R require a
minimum of 2 full days under mains power to reach full backup capacity. DO
NOT use any other kind of battery except as specified in this user guide. DO
1
User Guide
PLEASE READ AND SAVE
INSTALLER: Please leave this user guide with the product.
KF10
KF10LL
KF10R
Ionisation
KF20
KF20LL
KF20R
Optical
EN14604:2005
LICENSE NO. KM 738872
2797-CPR-535595
15
EN 14604:2005
!
1374-7205-04(KF10_KF20_KF10R_KF20R)_EN_KM738872:_ 2021.6.10 3:12
NOT connect this smoke alarm to any other type of smoke alarm or auxil-
iary device, except those listed in this user guide.
DO NOT remove or disconnect battery or turn off AC power to quiet
unwanted alarms. This will remove your protection. Open windows or fan
the air around smoke alarm to silence it. KF10, KF10LL, KF10R, KF20, KF20LL
and KF20R smoke alarms feature a Hush Button which, when activated, will
quiet unwanted alarms for up to 9 minutes.
The Push-to-Test button accurately tests all smoke alarm func-
tions. DO NOT use any other test method. Test smoke alarm week-
ly to ensure proper operation.
This smoke alarm should be installed only by a qualified
electrician.
This smoke alarm is designed to be used inside a single family
household only. In multi-family buildings, each individual living unit
should have its own smoke alarms. Do not install in non-residential
buildings or places which house many people like hotels, motels,
dormitories, hospitals, nursing homes, or group homes of any kind.
This smoke alarm is not a substitute for a complete alarm system.
Install a smoke alarm in every room and on every level of the home.
Smoke may not reach the smoke alarm for many reasons. For example,
if a fire starts in a remote part of the home, on another level, in a chim-
ney, wall, roof, or on the other side of a closed door, smoke may not
reach the smoke alarm in time to alert household members. A smoke
alarm will not promptly detect a fire EXCEPT in the area or room in
which it is installed.
Interconnected smoke alarms installed in every room and on every
level of the household offers maximum protection. We recommend
interconnecting smoke alarms so that when one smoke alarm senses
smoke and sounds its alarm, all others will sound as well. Do not
interconnect smoke alarms from one individual family living unit to
another. Do not connect this smoke alarm to any other type of alarm or
auxiliary device.
Smoke alarms may not alert every household member every time.
The alarm horn is loud in order to alert individuals of a potential
danger. However, there may be limiting circumstances where a
household member may not hear the alarm (i.e. outdoor or indoor
noise, sound sleepers, drug or alcohol usage, the hearing impaired,
etc.). If you suspect that this smoke alarm may not alert a household
member, install and maintain specialty smoke alarms. Household
members must hear the alarm’s warning sound and quickly respond to
it to reduce the risk of damage, injury, or death that may result from
fire. If a household member is hearing impaired, install special smoke
alarms with lights or vibrating devices to alert occupants.
Smoke alarms can only sound their alarms when they detect
smoke. Smoke alarms detect combustion particles in the air. They do
not sense heat, flame, or gas. This smoke alarm is designed to give
audible warning of a developing fire. However, many fires are
fast-burning, explosive, or intentional. Others are caused by
carelessness or safety hazards. Smoke may not reach the smoke
alarm QUICKLY ENOUGH to ensure safe escape.
Smoke alarms have limitations. This smoke alarm is not fool-proof
and is not warranted to protect lives or property from fire. Smoke
alarms are not a substitute for insurance. Homeowners and renters
should insure their lives and property. In addition, it is possible for the
smoke alarm to fail at any time. For this reason, you must test the
smoke alarm weekly and replace every 10 years.
SMOKE ALARM PLACEMENT
It is recommended to achieve complete
coverage protection by installing
a smoke alarm in every room of your
home.
At a minimum, smoke alarms shall be
installed outside or inside all bedrooms
and on each additional storey of the family
living unit including basements, and con-
verted loft spaces. Any home requires a
minimum of two smoke alarms.
Typical Single Storey Home
Install a smoke alarm on the ceiling or
wall inside each bedroom and in the
hallway outside each separate sleeping
area. If a bedroom area hallway is more
than 9 m long, install a smoke alarm at
each end.
Typical Two-Storey Home
Install a smoke alarm on the ceiling
inside each bedroom and in the hall-
way outside each separate sleeping
area.
If a bedroom area hallway is more than 9 m long, install a smoke
alarm at each end.
Install a smoke alarm at the top and bottom of a first-to-second floor
stairwell.
2
KITCHEN
FAMILY ROOM BEDROOM
BEDROOM
BEDROOM
FIREPLACE
DINING
ROOM
ATTIC OFFICE
BEDROOM BEDROOM
KITCHEN
LIVING ROOM
GARAGE
DINING ROOM KITCHEN
LIVING ROOM
BEDROOM
BEDROOM BEDROOM
Key
Ionisation Alarm
Heat Alarm
Optical Alarms
1374-7205-04(KF10_KF20_KF10R_KF20R)_EN_KM738872:_ 2021.6.10 3:12


Produkt Specifikationer

Mærke: Kidde
Kategori: Røgdetektor
Model: KF20R

Har du brug for hjælp?

Hvis du har brug for hjælp til Kidde KF20R stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor Kidde Manualer

Kidde

Kidde CO120X Manual

11 December 2024
Kidde

Kidde 3SFWR Manual

24 September 2024
Kidde

Kidde KF30R Manual

24 September 2024
Kidde

Kidde P4010ACS-WCA Manual

24 September 2024
Kidde

Kidde P4010DCSCO-WCA Manual

24 September 2024
Kidde

Kidde i12020CA Manual

24 September 2024
Kidde

Kidde i12040CA Manual

24 September 2024
Kidde

Kidde KF20R Manual

24 September 2024
Kidde

Kidde CP9000CA Manual

24 September 2024
Kidde

Kidde Pi2010CA Manual

24 September 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

Hochiki

Hochiki HCA-4 Manual

26 Februar 2025
Hochiki

Hochiki SOC-24V Manual

25 Februar 2025
Hochiki

Hochiki ALN-V Manual

25 Februar 2025
Hochiki

Hochiki ACC-V Manual

25 Februar 2025
First Alert

First Alert SMICO110 Manual

23 Februar 2025
Drayton

Drayton CCT599002 Manual

20 Februar 2025
LogiLink

LogiLink SC0016 Manual

29 Januar 2025
FirstAlert

FirstAlert SA700CE Manual

12 Januar 2025