Læs gratis den danske manual til Klein Tools 60552 (5 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 12 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 6.5 anmeldelser. Har du et spørgsmål om Klein Tools 60552, eller vil du spørge andre brugere om produktet?

Side 1/5
60552
(M/L - M/G)
60553
(S/M - P/M)
FIG. 1
FIG. 4
FIG. 3
FIG. 6
BASED ON: 1390554 Rev 05/23 A
10.016.0638.00.AA
8
9
ENGLISH
FEATURES
1.
Lower Strap
2.
Upper Strap
3.
Lower Strap Clip End 2)
4.
Lower Strap Buckle (×2)
5.
Upper Strap Clip End (×2)
6.
Upper Strap Buckle 2)
7.
Bottom Tab
8.
Exhalation Valve
9.
Face Piece
10.
Inhalation Valves (×2)
11.
Respirator Body
12.
Grille
13.
1/4-Turn Latches2)
14.
Sample Port Plug
FIG. 2
FIG. 5
12
2
6
4
7
1
11
13
5
3
14
CARACTERÍSTICAS
1.
Correa inferior
2.
Correa superior
3.
Extremo del clip de la correa inferior (×2)
4.
Hebilla de la correa inferior 2)
5.
Extremo del clip de la correa superior (×2)
6.
Hebilla de la correa superior 2)
7.
Pesta inferior
8.
Válvula de exhalación
9.
Pieza facial
10.
Válvulas de inhalación (×2)
11.
Cuerpo del respirador
12.
Rejilla
13.
Bloqueos de 1/4 de vuelta2)
14.
Tapón del puerto de muestras
ESPAÑOL
CARACTÉRISTIQUES
1.
Courroie inférieure
2.
Courroie supérieure
3.
Extrémité de la courroie inférieure (×2)
4.
Boucle de la courroie inférieure (×2)
5.
Extrémité de la courroie supérieure (×2)
6.
Boucle de la courroie supérieure (×2)
7.
Languette inrieure
8.
Soupape d’expiration
9.
Masque
10.
Soupape d’inhalation (×2)
11.
Corps du respirateur
12.
Grille
13.
Loquet à quart de tour (×2)
14.
Orifice pour prise d’échantillon
FRANÇAIS
P100 HALF-MASK RESPIRATOR INSTRUCTIONS
INSTRUCCIONES DEL RESPIRADOR DE MEDIA
CARA P100
INSTRUCTIONS POUR LE DEMI-MASQUE
RESPIRATOIREP100
GENERAL SPECIFICATIONS
STANDARDS
The P100 Half Mask Respirator 60552 / 60553 is approved as a half-mask respirator in accordance with NIOSH Standards
42 CFR Part 84. The P100 filter 60554 is part of the approved assembly and only when the above items are used togethe
is the device approved for occupational applications
APPLICATIONS
The P100 half-mask respirator together with P100 filters give protection against all particulate aerosols; including soli
and liquid particules such as dust, metal fumes, and oil mist. The protection provided by classification P100 also cover
the protection provided by lower class filters. Guidelines for the selection and use may vary between countries, alway
check prior to use to ensure that your selection for the intended application meets national requirement
WARNINGS
To ensure safe operations, follow these instructions. Failure to observe these warnings instructions may result in
sickness or death.
NOT FOR USE
in atmospheres containing less than 19.5% oxygen
NOT FOR USE
in atmospheres immediately dangerous to life or health
DO NOT
exceed maximum use concentrations established by regulatory standards. Failure to properly use and
maintain this product could result in injury or death
Follow the manufacturers Users Instructions for changing cartridges, canisters and/or filters
All approved respirators shall be selected, fitted, used and maintained in accordance with MHSA, OSHA and othe
applicable regulations
NEVER
substitute, modify, add or omit parts. Use only exact replacement parts in the configuration as specified by th
manufacturer
Refer to users instructions and/or maintenance manuals for information on use and maintenance of these respirator
NIOSH does not evaluate respirators for use as surgical masks
ALWAYS
conduct a pressure face fit check prior to each use. If the check fails the respirator may be faulty or require
replacement depending on age, frequency of use and replacement of filters
The use of this respirator presupposes exact knowledge of the instructions for use, applicable health and safet
standards, guidelines for selection and use, and appropriate training in matters of personal respiratory protection
Leave the contaminated area immediately if
Dizziness or distress is experienced
You taste or smell contaminants or irritation occurs
Breathing becomes difficult
A defect is discovered in the respirator
Store respirator as per instructions
Before occupational use of this respirator a written respiratory protection program must be implemented meeting a
the local government requirements. In the United States employers must comply with OSHA 29 CFR 1910.134 whic
includes medical evaluation, training, and fit testing
FITTING
The respirator must be inspected by the wearer before and after each use to ensure that it is in good working conditio
and valves and filters are seated correctly. Remove eyewear (if worn). If facial hair goes beyond the border of the
respirator, an effective seal will not be achieved, and a powered respirator will be required
NOTE:
OSHA regulations
require that all users be fit tested prior to use either qualitatively or quantitatively.
1.
Hold the respirator with one hand and the Lower Strap
1
with the other hand, put the Headband over your head and
allow to rest around the neck (FIG. 1)
2.
Place the respirator over mouth and nose then lift the Upper Strap
2
over the crown of your head to support the
respirator. Ensure that the straps are not twisted and are sitting flat against the head (FIG. 2)
3.
Grip Lower Strap Clip End(s)
3
at the Lower Strap Buckle(s)
4
and gently pull towards back of head to tighten (FIG. 3)
4.
Grip Upper Strap Clip Ends
5
at the Upper Strap Buckle(s)
6
, and gently pull towards back of head to tighten. Check
respirator is seated correctly and tight enough to prevent air leakage between respirator and face (FIG. 4)
5.
Clip all Strap Clip Ends
3
5
onto the Upper and Lower Straps
1
,
2
so that none of the strap ends are hanging
loosely (FIG. 5).
6.
POSITIVE PRESSURE FACE FIT CHECK:
Grab the Bottom Tab
7
and push in to seal off the exhalation valve
8
.
Next, exhale moderately. If the face piece
9
bulges slightly and no air leaks between the face and the Face Piec
9
are detected, a proper fit is achieved. If air leakage is detected, reposition the respirator on the face and/or readjust th
Straps
1
,
2
to eliminate the leakage (FIG. 6)
SAMPLE PORT
The Sample Port can be used to perform non-destructive quantitative fit-testing. Ensure the Sample Port Plug
14
is fully
inserted and seated when using this respirator
PERIODIC AND DEEP CLEANING
ALWAYS REMOVE FILTERS PRIOR TO ANY CLEANING ACTIVITY - DO NOT WASH FILTERS.
Both periodic and deep cleaning should be logged as part of the respirator routine
PERIODIC CLEANING:
Clean
Face Piece
9
assembly periodically with a soft cloth and mild soapy water (no solvents)
DEEP CLEANING:
When necessary, deep-clean per the following procedure
1.
Disassemble Respirator Body by rotating the 1/4-Turn Latches
13
counterclockwise and removing the Grille
12
,
filters, and Head Straps
,
2
from the Respirator Body
11
(FIG. 7)
NOTE: Valve bodies
8
,
10
are integral to the
respirator body and remain in place.
ma
i
1
2.
Immerse Respirator Body
11
and Grille
12
in warm water and scrub with soft brush. Neutral detergent may be used i
necessary.
Respirator Body
11
can also be soaked in a disinfectant for a short period of time
3.
All parts should then be rinsed in clean, warm water and allowed to air dry in a non-contaminated atmosphere
4.
Reassemble straps through the strap tabs in the Grille
12
, Replace filters with new (Cat. No. 60554) and reattach the
Grille
12
to the Respirator Body using the 1/4-Turn Latches
13
STORAGE
The respirator should be stored out of direct sunlight, away from sources of high temperature, and in an uncontaminated
environment. Spare filters should also be stored in a cool dry atmosphere at a temperature of between 1F (-10°C) and
104°F (4C). Storage under conditions other than those specified may affect shelf life. Respirator must be discarded
when it reaches its expiration date printed on exterior of packaging
FILTER INSPECTION & REPLACEMENT
Inspect respirator and filter before and after use for damage such as tears or cracks and immediately replace o
discard as required. Filters should be changed once a month or more frequently if you find a resistance to breathing
A maintenance record should be kept of these filter changes. Filter fitting instructions are supplied with replacemen
filters (Refer to instructions with Klein Tools Cat. No. 60554 or on www.kleintools.com for full details). Each filter pack is
individually marked with the month and year of their expiration date. Shelf life is 5 years for P100 filters. Filters must b
discarded when they reach their Expiration date
S – SPECIAL OR CRITICAL USER INSTRUCTIONS
These P100 Half-Mask Respirator(s), sizes S/M (P/N: 60553) or M/L (P/N:60552) used with filter (P/N:
60554), have been manufactured by Air Filtration Solutions for Klein Tools under TC-84A-9447.
WARRANTY
www.kleintools.com/warranty
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069 1-800-553-4676
customerservice@kleintools.com
www.kleintools.com
Read instructions
before using
104°F
(4C)
14°F
(-10°C)
0 – 95%
R.H.
Temperature range of storage
conditions
Year/Month
Expiration date
<95%
R.H.
Humidity range of storage conditions
ENGLISH
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
CONSERVE ESTAS INSTRUCCIONES PARA CONSULTARLAS EN EL FUTURO


Produkt Specifikationer

Mærke: Klein Tools
Kategori: Ikke kategoriseret
Model: 60552

Har du brug for hjælp?

Hvis du har brug for hjælp til Klein Tools 60552 stil et spørgsmål nedenfor, og andre brugere vil svare dig